Preview

BOURDON TUBE PRESSURE GAUGE

Better Essays
Open Document
Open Document
1417 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
BOURDON TUBE PRESSURE GAUGE
BOURDON TUBE PRESSURE GAUGE
Bourdon Tubes are known for its very high range of differential pressure measurement in the range of almost 100,000 psi (700 MPa). It is an elastic type pressure transducer.
The device was invented by Eugene Bourdon in the year 1849. The basic idea behind the device is that, cross-sectional tubing when deformed in any way will tend to regain its circular form under the action of pressure. The bourdon pressure gauges used today have a slight elliptical cross-section and the tube is generally bent into a C-shape or arc length of about 27 degrees.

As seen in the figure, the pressure input is given to a socket which is soldered to the tube at the base. The other end or free end of the device is sealed by a tip. This tip is connected to a segmental lever through an adjustable length link. The lever length may also be adjustable. The segmental lever is suitably pivoted and the spindle holds the pointer as shown in the figure. A hair spring is sometimes used to fasten the spindle of the frame of the instrument to provide necessary tension for proper meshing of the gear teeth and thereby freeing the system from the backlash. Any error due to friction in the spindle bearings is known as lost motion. The mechanical construction has to be highly accurate in the case of a Bourdon Tube Gauge. If we consider a cross-section of the tube, its outer edge will have a larger surface than the inner portion. The tube walls will have a thickness between 0.01 and 0.05 inches.

WORKING

As the fluid pressure enters the bourdon tube, it tries to be reformed and because of a free tip available, this action causes the tip to travel in free space and the tube unwinds. The simultaneous actions of bending and tension due to the internal pressure make a non-linear movement of the free tip. This travel is suitable guided and amplified for the measurement of the internal pressure. But the main requirement of the device is that whenever the same pressure is

You May Also Find These Documents Helpful

  • Satisfactory Essays

    PEX 01 03

    • 741 Words
    • 8 Pages

    Predict Question 2: What do you think will be the pressure result of the current experimental conditions?…

    • 741 Words
    • 8 Pages
    Satisfactory Essays
  • Satisfactory Essays

    For ‘EXPERIMENTAL’ tubes – state the purpose, results AND interpret the results of the experiment.…

    • 592 Words
    • 3 Pages
    Satisfactory Essays
  • Good Essays

    Txv Information

    • 830 Words
    • 4 Pages

    • A sensing bulb, connected by a length of capillary tubing, transmits bulb pressure to the top of the valve’s…

    • 830 Words
    • 4 Pages
    Good Essays
  • Better Essays

    The stagnation pressure , p0∞, is close to the atmospheric pressure of the lab and with only a small error ,is taken to be equal to the settling chamber pressure. The reference staticpressure, p∞, is measured via a pressure tapping in the floor of the working section, well upstream of the…

    • 2069 Words
    • 9 Pages
    Better Essays
  • Better Essays

    Part I of this experiment was specifically designed to validate Boyle’s Law, through the use of a homemade barometer. The open-end tube of the barometer, when moved to different heights above or below its equilibrium, visually achieves the application of various pressures (P) in which the volume (V) corresponding to it, can be measured. If pressure (P) times the corresponding volume (V) is a constant within the experimental error, it validates Boyle’s Law as the “volume of a sample of gas at a given temperature varies inversely with the applied pressure”.…

    • 1293 Words
    • 6 Pages
    Better Essays
  • Good Essays

    Year 12 Biology Research

    • 540 Words
    • 3 Pages

    The pulse oximeter and the Arterial Blood Gas Analysis Machine allow for the concentration and saturation of both gases to be measured.…

    • 540 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Unit two Biology

    • 7492 Words
    • 30 Pages

    As the two tubes are connected by the manometer these pressure changes are cancelled out. Pressure changes affecting one tube but not the other will cause the manometer fluid to show a difference in height on the two sides of the U-tube. The apparatus is assembled with both three-way taps open to the air, to prevent the manometer fluid being pushed into the tubes. However, during an experiment both three-way taps are closed to prevent air movement between the air in the apparatus and air in the laboratory, as shown in Figure 2.18. The difference between the levels of manometer fluid on the two sides of the U-tube represents the pressure difference between the air in the two tubes.…

    • 7492 Words
    • 30 Pages
    Powerful Essays
  • Satisfactory Essays

    This double chambered respirometer, allows you to measure the pressure changes, due to the presence of a control tube.…

    • 360 Words
    • 2 Pages
    Satisfactory Essays
  • Powerful Essays

    Hoop stress can be used for both Cylinder and Spherical Pressure vessels where as Longitudinal is only used for Cylinders.…

    • 1815 Words
    • 9 Pages
    Powerful Essays
  • Good Essays

    measured it and I got 77.65g and I continued adding 15 ml until I had…

    • 1647 Words
    • 7 Pages
    Good Essays
  • Good Essays

    Hiding from Reality

    • 952 Words
    • 4 Pages

    The American Dream for many it means the ideals of freedom, equality and opportunity traditionally held by every American. A life of personal happiness in short terms. However this “American Dream “is different for everyone, and it is now being threaten by many factors such as the economy, which is a big part of it, employment and our education as well are being demolished.…

    • 952 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Sound Wave

    • 564 Words
    • 3 Pages

    open end of a tube, a wave compression passes along the tube. When it reaches…

    • 564 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Reciprocating Compressor

    • 1531 Words
    • 7 Pages

    compressor for piston displacement of 21.4 cfm. B asic component of double acting reciprocating air compressor are designed.…

    • 1531 Words
    • 7 Pages
    Powerful Essays
  • Better Essays

    column. There were two gauges, one to measure the vertical deflection and the other, the…

    • 1039 Words
    • 5 Pages
    Better Essays
  • Good Essays

    Pressure and the Gas Laws

    • 396 Words
    • 2 Pages

    . Manometers are used in atmospheric surveys, weather studies, gas analyses and research of the atmospheres of other planets. They are usually made of glass or plastic, and while most are scored for measurement, some can measure changes digitally. The single-tube manometer measures only the pressure of a liquid, since there is no alternate place to compare gases. A U-shaped manometer essentially pits two different gas pressures against one another, and measures the strength of the captured gas. The free-flowing gas is usually air at the current atmospheric level.…

    • 396 Words