Preview

Chemical Analysis of Hydraulic Cement

Powerful Essays
Open Document
Open Document
30122 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
Chemical Analysis of Hydraulic Cement
Designation: C 114 – 07

Standard Test Methods for

Chemical Analysis of Hydraulic Cement1
This standard is issued under the fixed designation C 114; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.

1. Scope*
1.1 These test methods cover the chemical analyses of hydraulic cements. Any test methods of demonstrated acceptable precision and bias may be used for analysis of hydraulic cements, including analyses for referee and certification purposes, as explained in Section 3. Specific chemical test methods are provided for ease of reference for those desiring to use them. They are grouped as Reference Test Methods and
Alternative Test Methods. The reference test methods are long accepted classical chemical test methods which provide a reasonably well-integrated basic scheme of analysis for hydraulic cements. The alternative test methods generally provide individual determination of specific components and may be used alone or as alternates and determinations within the basic scheme at the option of the analyst and as indicated in the individual method.
1.2 Contents:
Section
2
3
3.1
3.2
3.3
3.4
4
4.1
4.2
4.3
4.4
4.5
4.6

--`,,````,,``,,,,`,,,`,``````,``-`-`,,`,,`,`,,`---

5
6
6.2
6.3
7
8
9
10
11
12
13
14

15
15.1
15.2
16
16.1
16.2
17
17.1
17.2
18
19
20
21
22
23
24
24.1
25
26
27
28
Appendices
Appendix X1

Subject
Referenced Documents
Number of Determinations and Permissible Variations
Referee Analyses
Optional Analyses
Performance Requirements for Rapid Test Methods
Precision and Bias
General
Interferences and Limitations
Apparatus and Materials
Reagents
Sample Preparation
General Procedures
Recommended Order for Reporting Analyses

You May Also Find These Documents Helpful

  • Better Essays

    1 This section deals with increase money supply given two scenarios (see “a” and “b” below).…

    • 954 Words
    • 8 Pages
    Better Essays
  • Good Essays

    Step 4: The cement and casing are then pressure tested to ensure hydrocarbons and other fluids don’t seep out.…

    • 724 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Lab Report Surfactant

    • 659 Words
    • 3 Pages

    4- Measure how many drops fit until the drops break the surface tension of the water.…

    • 659 Words
    • 3 Pages
    Good Essays
  • Good Essays

    * Rod each layer 25 strokes with tamping tod, distributing the stroke across the section of each layer.…

    • 326 Words
    • 2 Pages
    Good Essays
  • Good Essays

    (Supersedes SAS No. 7.) Source: SAS No. 84; SAS No. 93. Effective with respect to acceptance of an engagement after March 31, 1998, unless otherwise indicated.…

    • 3745 Words
    • 15 Pages
    Good Essays
  • Powerful Essays

    local sand with a top size of 0.0236 in. (600 μm), and locally available Type I/II cement…

    • 4613 Words
    • 19 Pages
    Powerful Essays
  • Good Essays

    cement has been investigated to give guidance for its use in fasttrack construction. Measurements of temperature rise under…

    • 7183 Words
    • 29 Pages
    Good Essays
  • Better Essays

    Rebound Hammer Report

    • 2040 Words
    • 9 Pages

    Rebound hammer test is undertaken using Schmidt’s hammer L-type (N-type for concrete material). Test procedure is simple and equipment is portable and easy to operate. Test can be undertaken on site and the number of test is unlimited. Test can be carried out on the surface of irregular block or, on core samples does not involve destruction of sample (minimize sample usage). Index value obtained is rebound number (R), which is an indicator on the degree of hardness of rock surface being tested. Rebound hammer test is frequently used in estimating the compressive strength of joint surface in rock. The value of R can be used to estimate the compressive strength of rock using the following equation (Franklin, 1989):…

    • 2040 Words
    • 9 Pages
    Better Essays
  • Satisfactory Essays

    design mix

    • 419 Words
    • 2 Pages

    Since from the table above, water-cement ratio by weight for non-entrained mix of 0.68 is required,…

    • 419 Words
    • 2 Pages
    Satisfactory Essays
  • Powerful Essays

    Astm E3-95

    • 7511 Words
    • 31 Pages

    adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript…

    • 7511 Words
    • 31 Pages
    Powerful Essays
  • Satisfactory Essays

    The concrete slump test is an empirical test that measures the workability of fresh concrete. More specifically, it measures the consistency of the concrete in that specific batch. This test is performed to check the consistency of freshly made concrete. Consistency is a term very closely related to workability. It is a term which describes the state of fresh concrete. It refers to the ease with which the concrete flows. It is used to indicate the degree of wetness. Workability of concrete is mainly affected by consistency i.e. wetter mixes will be more workable than drier mixes, but concrete of the same consistency may vary in workability. It is also used to determine consistency between individual batches.…

    • 327 Words
    • 1 Page
    Satisfactory Essays
  • Better Essays

    Report Spacific Gravity

    • 1614 Words
    • 7 Pages

    This test is intended to determine the specific gravity and absorption of coarse and fine aggregate samples.…

    • 1614 Words
    • 7 Pages
    Better Essays
  • Good Essays

    march funnel

    • 719 Words
    • 3 Pages

    Jump up ^ ASTM C939-10 Standard Test Method for Flow of Grout, ASTM International, 2010…

    • 719 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Task-1 1.1 Explain the quality control testing before you allow starting the concreting work for the foundation, columns, slab and beams. There are two main tests to be done on concrete The slump test: the slump test shows the workability of concrete. The compression test: the compression test shows the best possible strength Concrete can reach in perfect conditions. Testing should always be done carefully. Wrong test results can be costly. SAMPLING The first step is to take a test sample from the large batch of concrete. This should be done as soon as discharge of the concrete commences. The sample should be representative of the concrete supplied. The sample is taken in one of two ways: For purposes of accepting or rejecting the load: Sampling after 0.2 m3 of the load has been poured. For routine quality checks: Sampling from three places in the load.…

    • 6544 Words
    • 27 Pages
    Good Essays
  • Powerful Essays

    Testing Materials

    • 1765 Words
    • 8 Pages

    Certified that this is the bonafide research work of Mr. Albert M. Dintweng and has a Summarized title; Laboratory Testing Of Highway Materials Instructions. Compiled from January 2011 until December 2011.…

    • 1765 Words
    • 8 Pages
    Powerful Essays