Contents lists available at ScienceDirect
International Journal of Heat and Mass Transfer journal homepage: www.elsevier.com/locate/ijhmt
Numerical simulation of parabolic trough solar collector: Improvement using counter flow concentric circular heat exchangers
O. García-Valladares a,*, N. Velázquez b a b
Centro de Investigación en Energía, Universidad Nacional Autónoma de México, Privada Xochicalco s/n, Temixco, Morelos 62580, Mexico
Instituto de Ingeniería, Universidad Autónoma de Baja California, Blvd. Benito Juárez y Calle de la Normal s/n, Mexicali, Baja California 21280, Mexico
a r t i c l e
i n f o
Article history:
Received 2 April 2008
Received in revised form 7 August 2008
Available online 20 September 2008
Keywords:
Concentration
PTC
Numerical model
Solar energy
Heat exchanger
Double pipe
a b s t r a c t
Detailed numerical simulations of thermal and fluid-dynamic behavior of a single-pass and double-pass solar parabolic trough collector are carried out. The governing equations inside the receiver tube, together with the energy equation in the tube walls and cover wall and the thermal analysis in the solar concentrator were solved iteratively in a segregated manner. The single-pass solar device numerical model has been carefully validated with experimental data obtained by Sandia National Laboratories.
The effects of recycle at the ends on the heat transfer are studied numerically shown that the double-pass can enhance the thermal efficiency compared with the single-pass.
Ó 2008 Elsevier Ltd. All rights reserved.
1. Introduction
In order to deliver high temperatures with good efficiency a high performance solar collector is required. Systems with light structures and low cost technology for process heat application up to 400 °C could be obtained with Solar Parabolic Trough Collector (solar PTC). These systems can effectively produce temperatures between 50 and 400 °C [1].
PTCs are made by bending a sheet of reflective surface into a parabolic shape. Typically a single phase fluid circulating through a metal black tube receiver, covered with a glass tube (with vacuum or air in the space between the receiver and cover) to decrease convective heat losses, is placed along the focal line of the receiver. The surface of receiver is typically covered with a selective coating that has a high absorptance for solar radiation, but low emittance for thermal radiation loss. It is sufficient to use a single axis tracking of the sun and thus long collector modules that are supported by pedestals are produced.
Solar PTC with evacuated tubular receivers is the main technology currently used in solar thermal electrical power plants (but it is also used in steam generation, absorption cooling, seawater distillation, etc.) because of considerable experience with the systems and the development of small commercial industry to produce and market these systems.
Sandia National Laboratories performed test on a typical solar
PTC to determine the thermal loss and collector efficiency of the
* Corresponding author. Tel.: +52 55 56229746; fax: +52 55 56229791.
E-mail address: ogv@cie.unam.mx (O. García-Valladares).
0017-9310/$ - see front matter Ó 2008 Elsevier Ltd. All rights reserved. doi:10.1016/j.ijheatmasstransfer.2008.08.004 LS2 Solar Thermal Electric Generation Systems (SEGS) [2]. Chrome black and Cermet selective coatings were studied together with three receiver configurations: glass envelope with vacuum or air in the receiver annulus, and a bare receiver tube. Dudley et al.
[2] derived performance correlations relating collector efficiency and thermal loss to working fluid temperature by simple polynomial correlation of the test data. An incidence angle modifier was also developed by measuring the efficiency of the collector for a range of incidence angles.
A direct steam generation collector (DSG) has been proposed [3] as a development of the SEGS in order to eliminate the costly synthetic oil, intermediate heat transport piping loop and oil to stream heat exchanger. Kalogirou et al. [4] analyzed a low pressure steam generation system which is based on heating water in a PTC and then flashing to steam in a separate vessel. The flow in the solar
PTC is maintained in the liquid phase region.
A thermal model of a DSG collector was developed by Odeh et al. [5,6] to model heat loss in terms of receiver wall temperature rather than working fluid temperatures. When the model is compared with the Sandia test data, it was found to underestimate the measured loss. Odeh and Morrison [7] developed a transient numerical model for analyzing the performance of industrial water heating systems using PTC.
Nowadays, it is under construction Andasol 1, 2 and 3 in Spain.
These are plants of 50 MW based on a series of parabolic troughs, huge curved mirrors about 5.5 m wide. The mirrors slowly track the sun from east to west, and oil reaches about 400 °C.
In this paper, firstly a detailed numerical simulation of optical, thermal and fluid-dynamic behavior of a single-pass solar PTC is
598
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
Nomenclature
Aref
At
At,c
At,r
C
Cp
D
e exp fr
F
Fa
Frc
g h H
I
ID k K
L
m
_
m
M
n
Nu
p
P
PT
Pr
_ q _ qu _ qwall _
Q
_
Qu
Ra
Re
S t T v W xg z
aperture area (W Á L) [m2] fluid flow cross-section area [m2] cover tube cross-section area [m2] receiver tube cross-section area [m2] concentration ratio [dimensionless] specific heat at constant pressure [J/(kg K)] diameter [m] specific energy (H + v2/2 + gzsin h) [J/kg] experimental friction factor [dimensionless] focal distance [m] incident angle modifier [dimensionless] view factor between receiver and cover [dimensionless] gravitational constant [m/s2] heat transfer coefficient [W/(m2 K)] enthalpy [J/kg] solar irradiance [W/m2] improvement of solar PTC performance defined by Eq.
(44) [%] thermal conductivity [W/(m K)] channel thickness ratio (Di,int/Dr,int) [dimensionless] receiver length [m] mass [kg] mass flow rate [kg/s] recycle ratio [dimensionless] number of control volumes [dimensionless]
Nusselt number [dimensionless] pressure [bar] perimeter [m] friction power expenditure defined by Eq. (45) [W]
Prandtl number [dimensionless] heat flow per unit area [W/m2] useful energy gain per receiver unit area [W/m2] heat flux from wall to fluid per receiver unit area [W/ m2] heat flow [W] energy gain [W]
Rayleigh number [dimensionless]
Reynolds number [dimensionless] solar absorbed energy per unit area [W/m2] time [s] temperature [K] velocity [m/s] collector width [m] vapor quality [dimensionless] axial coordinate
Greek symbols absorptance [dimensionless]
a
carried out. The governing equations (continuity, momentum, and energy) inside the solar PTC receiver tube, together with the energy equation in the tube wall and cover wall and the thermal analysis in the solar concentrator were solved iteratively in a segregated manner. Secondly, the numerical model has been carefully validated with experimental data obtained by Sandia National Laboratories for single-pass solar PTC with air and vacuum in the space between receiver and cover. Finally, the model has been extended in order to simulate solar PTC with counter flow concentric circular heat exchangers (double-pass) and it has been demonstrated numerically that it can enhance the thermal efficiency compared with a single-pass device.
d
e eg /
c g u h l q qo r s sw n
Dp
Dz
Dt
U
rate of convergence [K] emittance [dimensionless] void fraction [dimensionless] aperture angle [rad] shape factor due to inexact concentrator orientation
[dimensionless]
efficiency [dimensionless] generic variable (Eq. (19)) inclination angle with respect to the horizontal [rad] dynamic viscosity [Pa s] density [kg/m3] surface reflectivity [dimensionless]
Stefan–Boltzman constant [5.6697 Â 10À8 W/(m2 K4)] cover transmittance [dimensionless] shear stresses [N/m2] tube roughness [m] pressure drop [Pa] spatial discretization step [m] temporal discretization step [s] two-phase frictional multiplier (sw/(sw)liquid_only)
[dimensionless]
Subscripts amb ambient atm atmospheric b beam c cover conv convective eff effective ext external f fluid g gas phase i internal tube int internal l liquid phase op optical r receiver rad radiative th thermal tp two-phase w, e, n, s neighbors (west, east, north, south)
Superscripts
* guessed values
–
arithmetical average over a CV
$
integral average over a CV o value of previous instant jþ1 ½Xj ¼ X jþ1 À X j
2. Mathematical formulation
The fluid enters into the receiver tube with a specific temperature (in the case of single phase flow) or quality (in the case of twophase flow), pressure and mass flow rate. The receiver tube re_ ceives a useful energy gain ðqu Þ of the sun. Finally, fluid exits the receiver with a pressure and temperature (in the case of single phase flow) or quality (in the case of two-phase flow) according to the boundary conditions found along the system.
A computational algorithm has been carried out in order to obtain the performance of a single-pass solar PTC with air or vacuum
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
599
Fig. 1. Heat transfer nomenclature for a single-pass solar PTC.
in the space between the receiver and cover (Fig. 1). The numerical model was divided in four subroutines: fluid flow inside the receiver tube, heat transfer in the receiver wall tube, heat transfer in the glass cover and solar thermal analysis.
The following assumptions have been made in the mathematical model:
The minimum diameter required in the receiver tube in order to intercept the entire reflected ray is calculated in the following form
[8]:
D¼
W sin 0:267 sin /
ð4Þ
The concentration ratio is defined by:
The solar PTC has a tracking system that perfectly follows the sun during the day.
The concentrator surface is specularly reflecting.
One dimensional flow.
Constant diameters and concentrator surfaces.
Negligible conduction losses at the ends of each trough.
W À Dr;ext pDr;ext For a solar PTC, the incident solar radiation absorbed per unit of area by the receiver tube is [8]:
_
The useful energy gain per unit of receiver area (qu Þ, expressed in terms of the local receiver temperature (Tr), cover temperature
(Tc) and the incident solar radiation absorbed per unit of area by the receiver tube (Sr) is given by Duffie and Beckman [8]:
ð1Þ
hrad;rÀc ¼
Sr
Ib
ð2Þ
The aperture angle is defined as (see Fig. 1):
"
À1
/ ¼ tan
16
F
8W
 F Ã2
W
#
À1
ð3Þ
ð6Þ
The useful energy gain depends on both solar radiation absorbed by the receiver tube and thermal losses with the surroundings.
The radiative heat transfer coefficient between the receiver tube and cover is expressed by Duffie and Beckman [8] in the following formula: The solar PTC optical efficiency is defined in the following form:
gop ¼
ð5Þ
À
Á
_ qu ¼ CSr À hconv;rÀc þ hrad;rÀc ðT r À T c Þ
2.1. Solar thermal analysis
Sr ¼ Ib qo sacF a
C¼
r T 2 þ T 2 ðT r þ T c Þ r c
1Àer
er
þ F1 þ rc ð1Àec ÞDr;ext ec Dc;int
ð7Þ
where view factor between the receiver and cover (Frc) is considered equal to 1.
Natural heat transfer convection in a non-evacuated annular space gap for horizontal concentric cylinders can be estimated by the following correlations [9]:
600
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
keff
¼ 0:317ðRaà Þ1=4 kair where
2
ð8Þ
À
Á
ln Dc;int =Dr;ext
3
6
7 1=4 ðRaà Þ1=4 ¼ 4
5=4 5Ra
3=4
3=5 b 1=D3=5 þ 1=Dc;int r;ext ð9Þ
in which b = (Dc,int À Dr,ext)/2 and the Rayleigh number, Ra, is based on the temperature differences in the annular space and the characteristic length b. The relation between the heat transfer coefficient hconv,rÀc and the effective thermal conductivity, keff, is given by:
hconv;rÀc ¼
2keff
Dr;ext lnðDc;int =Dr;ext Þ
ð10Þ
In the case of vacuum in the annular space between receiver and cover hconv,rÀc is considered equal to zero.
The solar PTC global thermal efficiency is defined in the following form:
gth ¼
_
Qu
Aref Ib
ð11Þ
The evaluation of the shear stresses are carried out by means of the friction factor (fr) and a two-phase multiplier (U) which are included in the following expression for wall shear stress:
_
sw ¼ Uðfr=4Þðm2 =2qtp A2 Þ. The one-dimensional model also requires t knowledge of the two-phase flow structure (if two-phase flow exists), which is evaluated by means of the void fraction (eg) and the heat transfer through the tube wall and the fluid temperature are related by the convective heat transfer coefficient (h).
2.2.1. Evaluation of empirical coefficients
The mathematical model requires some additional local information, generally obtained from empirical correlations. After comparing different empirical correlations presented in the technical literature, the following ones have been selected:
2.2.1.1. Single phase region (subcooled liquid or superheated vapor). The Gnielinski correlation [11] is used to calculate the heat transfer coefficient:
Nu ¼
ðf =8ÞðRe À 1000ÞPr pffiffiffiffiffiffiffiffiffiffiffiffi ;
1 þ 12:7 ðf =8ÞðPr 2=3 À 1Þ
where f ¼ ð1:82log10 Re À 1:64Þ
2.2. Fluid flow inside the receiver tube
and the friction factor is evaluated from the expression proposed by
Churchill [12]:
The mathematical formulation of two-phase flow is evaluated inside a fluid characteristic control volume (CV) of a tube (Fig. 2a), where
‘j’ and ‘j + 1’ represent the inlet and outlet sections, respectively.
Using as reference the geometry of the receiver tube (diameter, length, roughness and angle), the governing equations have been integrated assuming the following:
One-dimensional fluid flow: p(z, t), H(z, t), T(z, t), etc.
Axial heat conduction inside the fluid is neglected.
Separated flow model.
Constant internal diameter and uniform surface roughness.
The general semi-integrated governing equations over the above mentioned finite CV, have the following form [10]:
Continuity:
_
½mjjþ1 þ
om
¼0
ot
ð12Þ
Momentum:
Â
_ mg vg
Ãjþ1 j jþ1
_
þ ½ml vl j þ Dz
Energy:
Â
_
_
ml el þ mg eg
Ãjþ1 j ~
_
om
~
¼ À½pjþ1 At À sw PDz À mg sin h j ot
À
Á
e
e
~
o ml l þ mg g op X _
Q
þ
À A t Dz ¼ ot ot
where e = H + m2/2 + gzsin h.
ð15Þ
À2
ð13Þ
ð14Þ
fr ¼ 2
"
#1=12
12
8
1
þ
Re
ðA þ BÞ3=2
ð16Þ
where
(
A¼
B¼
"
,"
2:457 ln 1:0
##)16
0:9
7 n þ 0:27
:
Re
D
16
37530
Re
ð17Þ ð18Þ 2.2.1.2. Equilibrium two-phase region (if it exists). In the two-phase flow region, the void fraction is estimated from the equation of
Rouhani and Axelsson [13]. For the convective heat transfer coefficient, the boiling flow model proposed by Zürcher et al. [14] is applied. The friction factor is calculated from the same equation as in the case of subcooled liquid phase using a two-phase frictional multiplier according to Friedel [15].
Temperature, mass fraction and all the thermophysical properties are calculated using matrix functions of the pressure and enthalpy obtained using REFPROP v7.0 [16] (for air and water) and for silicone-base fluid (thermal oil) from data given by the manufacturer [17], i.e.:
u ¼ uðp; HÞ where u ¼ T; xg ; q; . . .
Fig. 2. Characteristics CV: (a) fluid CV and (b) tube wall CV.
ð19Þ
601
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
2.2.2. Fluid flow analysis
The numerical analysis is carried out in terms of a CV method.
The discretized equations are coupled using a fully implicit stepby-step method in the flow direction. From the known values at the inlet section and the wall boundary conditions, the variable values at the outlet of each CV are iteratively obtained from the discretized governing equations. Outlet values are the inlet values for the next CV. The procedure is carried out until the end of the receiver tube is reached.
For each CV, a set of algebraic equations is obtained by a discretization of the governing Eqs. (12)–(14) to obtain the value of the dependent variable (mass flow rate, pressure and enthalpy) at the outlet section of each CV.
The outlet mass flow rate is obtained from the discretized continuity equation (Eq. (12)),
At Dz
_
tp
¼ mj À qtp À qo
Dt
_ mjþ1 ð20Þ
where the two-phase density is obtained from: qtp = eg qg + (1 À eg)ql.
In terms of the mass flow rate, gas and liquid velocities are calculated as,
"
#
!
_
_
mxg mð1 À xg Þ
; vl ¼ qg eg At ql ð1 À eg ÞAt
vg ¼
ð21Þ
e oH ~
~
~
~
_
_
_
_
qwall pDr;int À qu pDr;ext Dz þ qw À qe At;r ¼ m ot ð27Þ
~
_
where qwall ¼ hf ðT r À T f Þ, and the conductive heat fluxes are evaluated using the Fourier law:
~
_
qe ¼ Àke
oT r oT r
~
_
; qw ¼ Àkw oz e oz w
ð28Þ
Substituting their respective heat fluxes and rearrangement Eq.
(27), the following equation has been obtained for each node of the grid:
aj T r;j ¼ bj T r;jþ1 þ cj T r;jÀ1 þ dj
ð29Þ
where the coefficients are:
At;r Dz kA qcp bj ¼ e t;r
Dt
Dz
À
Á
A Dz
_ u;j pDr;ext Dz þ t;r qcp T o dj ¼ hf ;j pDr;int T f ;j þ q r;j Dt aj ¼ bj þ cj þ hf ;j pDr;int Dz þ
cj ¼
kw At;r
Dz
The coefficients mentioned above are applicable for 2 6 j 6 nz À 1; for j = 1 and j = nz adequate coefficients are used taking into account the axial heat conduction or temperature boundary conditions. The set of heat conduction discretized equations is solved using the
TDMA algorithm [18].
2.4. Cover tube wall
The discretized momentum equation (Eq. (13)) is solved for the outlet pressure,
pjþ1
_
m2
Dz
¼ pj À
UrpDr;int
þ qtp At g sin h f At
tp A2
8q t
1
 ÁÃjþ1
_ m xg vg þ ð1 À xg Þvl j
_
_ m À mo A þ þ
Dz
Dt
ð22Þ
From the energy equation (Eq. (14)) and the continuity equation (Eq.
(12)), the following equation is obtained for the outlet enthalpy:
Hjþ1
t
_
_
_
2qwall pDr;int Dz À mjþ1 a1 þ mj a2 þ ADDz a3 t ¼
_
tp
_
mjþ1 þ mj þ qo At Dz=Dt
The same procedure mentioned above for the receiver tube wall has been used. Integrating the conduction equation over the cover tube wall CV, the following equation is obtained as result:
e oH ~
~
~
~
_
_
_
_
qs pDr;ext À qn pDc;ext Dz þ qw À qe At;c ¼ m ot ð30Þ
~
~
_
_
qe and qw are evaluated using the Fourier law and:
~
~
~
_
_
_
qs ¼ qconv;rÀc þ qrad;rÀc ¼ ðhconv;rÀc þ hrad;rÀc ÞðT r À T c Þ
ð31Þ
~
~
~
_
_
_
qn ¼ qconv;cÀamb þ qrad;cÀsky ð23Þ ¼ hconv;cÀamb ðT c À T amb Þ þ hrad;cÀsky ðT c À T sky Þ
ð32Þ
where
where
a1 ¼ ðxg vg þ ð1 À xg Þvl Þ2 þ g sin hDz À Hj jþ1 ð24Þ
a2 ¼ ðxg vg þ ð1 À xg Þvl Þ2 À g sin hDz þ Hj j
2
j
tp
j
j a3 ¼ 2 pj À po À qo Hj À 2Ho À qv2 À qo vo j T sky ¼ 0:0552T 1:5 amb
hrad;cÀsky ¼ ec r T 2 þ T 2 ðT sky þ T c Þ sky c
ð33Þ
ð25Þ ð26Þ The above mentioned equations of mass, momentum and energy are applicable to transient two-phase flow. Situations of steady flow and/or single-phase flow (subcooled liquid or superheated vapor) are particular cases of this formulation. Moreover, the mathematical formulation in terms of enthalpy gives generality of the analysis, because only one equation is needed for all the regions and gives opportunity for easily dealing with cases of mixtures of fluids.
2.3. Receiver tube wall
ð34Þ
And according to Karlekar and Desmond [19]:
kair for 0:4 < Re 6 40 ð35Þ Dc;ext kair ¼ 0:683Re0:486 Pr1=3 for 40 < Re 6 4000 ð36Þ Dc;ext kair ¼ 0:193Re0:618 Pr1=3 for 4000 < Re 6 40; 000
Dc;ext
hconv;cÀamb ¼ 0:989Re0:33 Pr1=3 hconv;cÀamb hconv;cÀamb
ð37Þ hconv;cÀamb kair
¼ 0:0266Re0:805 Pr1=3
Dc;ext
for 40; 000 < Re 6 400; 000 ð38Þ The conduction equation has been written assuming onedimensional transient temperature distribution (the radiant flux is not uniform at 360° around the receiver however due to the small receiver tube diameter and the tube thermal conductivity a one-dimensional temperature distribution has been assumed).
A characteristic tube wall CV is shown in Fig. 2b, where P represents the central node, E and W indicate its neighbors. The CV-faces are indicated by e, w, n and s. Integrating the conduction equation over this CV, the following equation is obtained:
Finally, hconv,cÀamb is taken as the maximum value between one of its corresponding above correlation and the following correlation for natural convention around cylinders developed by Churchill and Chu [20]:
0
0
B
B
hconv;cÀamb ¼ @0:6 þ 0:387@
11=6 12
1þ
Ra
C
À0:559Á9=16 16=9 A
Pr
C kair
A
Dc;ext
ð39Þ
602
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
3. Numerical solution of single-pass solar PTC
The solution process is carried out on the basis of a global algorithm (programmed in C language) that solves in a segregated manner the fluid flow inside the receiver tube, the heat conduction in the receiver tube wall, the heat conduction in the cover tube wall and the solar PTC thermal analysis. The coupling between the four main subroutines is performed iteratively following the procedure described below (see Fig. 3):
1. For fluid flow inside the receiver tube, the equations are solved considering the receiver tube wall temperature distribution as a boundary condition, and evaluating the temperature and the convective heat transfer coefficient in each fluid CV.
2. In the receiver tube wall, the temperature distribution is re-calculated using the fluid flow temperature and the convective heat transfer coefficient evaluated in the preceding step, and considering the useful energy gain as boundary condition.
3. In the cover tube wall, the temperature distribution is calculated using the receiver tube wall, ambient and sky temperatures and the convective and radiative heat transfer coefficients between the cover and receiver and cover and sky and ambient.
4. The useful energy gain is obtained in terms of the thermal analysis carried out on the solar PTC, and the receiver tube and cover temperature distributions calculated in the previous steps. The governing equations corresponding to a steady state situation are the same equations developed without considering the temporal derivative terms. The global convergence is reached when in two consecutive loops of the four main subroutines; a strict convergence criterion is verified for all the CVs in the domain
(for more detail [10]).
4. Single-pass solar PTC model validation
In order to validate the numerical model developed a comparison with the experimental data obtained by Sandia National Laboratories for a single-pass solar PTC with air and vacuum in the space between the receiver and cover working with a single-phase water and syltherm 800 oil (silicone-based fluid) under different working conditions [2] has been carried out. Cermet a graded ceramic/metal selective surface coating to the steel receiver by a vacuum sputtering process was used in the experimental tests. The detailed solar PTC specifications are given in Table 1. Due to the
AZTRAK rotating platform of Sandia National Laboratories is an azimuth-tracking platform, it can position a collector at zero incident angle (radiation normal incident to the plane of aperture, Fa = 1) at any hour of any day. The experimental test reported at zero incident angle have been using for comparison in this paper.
Validation of air and vacuum between receiver and cover is due to most of the design systems are vacuum ones but accidents during operation can produce vacuum lost or the glass envelope can be broken. Moreover air between receiver and cover technology is cheaper than vacuum systems. All the numerical results presented in this paper have been obtained using 300 CVs to get grid-independent solutions.
4.1. Air between receiver and cover
The first validation was against the single-pass experimental thermal losses from the receiver with air in the space between the receiver and cover as a function of operating temperature.
Experimentally, good thermal loss data is more difficult to obtain than heat gain (efficiency) data, because the temperature change across the receiver is smaller by as much as an order of magnitude.
A true measure of receiver thermal loss with zero contribution due to direct or scattered light absorption by the receiver can be
Table 1
Solar PTC specifications [2] used in the model validation
Fig. 3. Numerical algorithm flow diagram.
Receiver length (L)
Collector width (W)
Focal distance (F)
Receiver internal diameter (Dr,int)
Receiver external diameter (Dr,ext)
Receiver tube thermal conductivity (kr)
Glass cover internal diameter (Dc,int)
Glass cover external diameter (Dc,ext)
Concentration ratio (C)
Receiver absorptance (a)
Receiver emittance (er)
Glass cover transmittance (s)
Reflected surface reflectivity (qo)
Shape factor (c)
Inclination angle (h)
Incident angle modifier (Fa)
Optical efficiency (gop)
Atmospheric pressure (Albuquerque) (patm)
7.8 m
5m
1.84 m
0.066 m
0.070 m
54 W/m K
0.115 m
0.109 m
22.42
0.906
0.14
0.95
0.93
0.92
0.0
1.0
0.736
86 kPa
603
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
obtained by aiming the reflector at a clear sky, at night. Other tests have also shown that an equivalent loss value occurs during more normal daylight hours when the receiver is shaded from direct sunlight and the reflector is aimed at a clear sky (this experimental procedure was used by Sandia National Laboratories). The experimental error band reported on the data points are the expected worst-case errors caused by the measuring instruments [2]. The single-pass solar PTC numerical model comparison of the performance against experimental data is shown in Fig. 4a, the agreement here is very good; the model and test data essentially agree, within the bounds of experimental uncertainty, over the entire temperature range.
The second validation was against experimental measurements of zero incident angle efficiency made with water and oil at approximately ambient-air temperature, and at approximately
50 °C intervals up to 400 °C. The near ambient-air temperature measurement was used to define the approximate optical efficiency of the solar PTC (0.736). The higher temperature efficiency measurements document the decrease in efficiency caused by increasing thermal losses as the operating temperature is increased. The comparison of the performance between the numerical model developed and the experimental data is shown in Table
2. A good degree of correlation has been obtained for 11 data points evaluated for thermal efficiency of a single-pass solar PTC with air between receiver and cover, the maximum error is 6.02% with a mean deviation of ±2.59%. For the increment of temperature in the fluid: the maximum error is 5.99% or 1.07 °C with a mean deviation of ±2.52% or ±0.43 °C.
4.2. Vacuum between receiver and cover
In these cases, the numerical model considered that the natural heat transfer convection in the annular space between receiver and cover is negligible (hconv,rÀc = 0). A comparison between the singlepass solar PTC numerical model against thermal losses experimental data is shown in Fig. 4b, the model and test data essentially agree, within the bounds of experimental uncertainty, over the entire temperature range (temperature change across the receiver is smaller than in the case of air between receiver and cover, for this reason higher uncertainties are expected).
A comparison between the numerical model developed and the experimental data for a single-pass solar PTC with vacuum between
a 130
receiver and cover is shown in Table 3. A good degree of correlation has been obtained for 9 data points evaluated for thermal efficiency; the maximum error is 2.84% with a mean deviation of ±1.79%. For the increment of temperature in the fluid: the maximum error is 3.24% or 0.64 °C with a mean deviation of ±1.98% or ±0.39 °C. Comparison between air and vacuum in the space between receiver and cover show that elevated temperature performance is significantly degraded by increasing thermal losses when air fills this space.
The numerical model is based on the applications of governing equations and used general empirical correlations; for this reason, it is possible to make use of it with greater confidence to other fluids, mixtures and operating conditions (including two-phase flow); it allows using the model developed as an important tool to design and optimize these kinds of systems.
5. Solar PTC improvement using counter flow concentric circular heat exchangers (double-pass)
The recycle-effect concept is broadly used in absorption, fermentation, and polymerization industries. The effects of recycle in laminar flows have been widely studied in previous works. For example, the effects of recycle in laminar flows at the ends on the heat transfer through a concentric circular tube with uniform wall fluxes were studied analytically by Ho and Yeh [21]. The analytical model developed have the following assumptions: constant physical properties, uniform heat fluxes, fully developed laminar flow, negligible axial conduction and negligible thickness and thermal resistance in the impermeable tube. They demonstrated that the external recycle can enhance the heat transfer efficiency compared that with a single-pass device for laminar flows.
In general, numerical models are more accurate and general methods than analytical ones due to the governing equations are solved with fewer restrictions (for example, the model developed in this paper considers: variable physical properties, non uniform heat fluxes, axial conduction and thermal resistance in tubes, laminar and turbulent flow, etc.).
5.1. Mathematical formulation of double-pass device
A detailed numerical simulation of optical, thermal and fluiddynamic behavior of a Solar PTC with counter flow concentric
b 100
Numerical model
Sandia experimental data-shaded receiver with air in annulus
120
Numerical model
Sandia experimental data-shaded receiver with vacuum in annulus
90
110
80
Thermal losses [W/m2]
Thermal losses [W/m2]
100
90
80
70
60
50
40
70
60
50
40
30
20
30
10
20
0
10
0
0
100
200
300
Fluid temperature above ambient [oC]
400
-10
0
100
200
300
400
Fluid temperature above ambient [oC]
Fig. 4. Thermal losses comparison between Sandia experimental data and single-pass model developed for a shaded receiver with: (a) air between receiver and cover and (b) vacuum between receiver and cover. Error bars represent the measurement errors reported [2].
604
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
Table 2
Comparison between Sandia experimental data [2] for a single-pass solar PTC with air between receiver and cover and model developed
Case
1
2
3
4
5
6
7
8
9
10
11
Fluid
Water
Oil
Oil
Oil
Oil
Oil
Oil
Oil
Oil
Oil
Oil
Ib
(W/m2)
Flow rate
(1/min)
Wind speed
(m/s)
Tamb
(°C)
Tinlet
(°C)
exp DT
(°C)
Model
DT (°C)
% Error exp vs model
925.1
813.1
858.4
878.7
896.4
889.7
906.7
874.1
870.4
879.5
898.6
20.7
50.3
52.9
54.6
55.2
55.3
55.4
56.2
56.1
55.4
56.2
3.4
3.6
3.1
3.1
0.9
2.8
0.0
4.0
0.6
1.8
2.8
38.4
25.8
27.6
28.6
30.0
28.6
31.7
28.7
29.1
27.4
29.7
29.5
101.2
154.3
202.4
250.7
251.1
299.5
344.9
345.5
348.9
376.6
17.8
17.8
17.4
17.0
17.1
17.2
17.0
16.2
16.1
16.3
16.5
18.04
16.73
16.64
16.31
16.57
16.23
16.94
15.82
16.11
16.35
16.47
Average
Max
1.36
5.99
4.36
4.05
3.08
5.63
0.36
2.32
0.08
0.29
0.19
2.52
5.99
exp
gth (%)
73.68 ± 1.96
71.56 ± 2.21
69.20 ± 2.10
67.10 ± 1.88
65.50 ± 1.80
66.61 ± 2.29
62.58 ± 1.79
59.60 ± 2.27
59.40 ± 2.12
58.52 ± 2.02
56.54 ± 1.93
Model gth (%)
% Error exp vs model
72.11
67.25
66.21
64.60
63.65
62.89
62.39
58.56
59.74
58.99
56.83
Average
Max
2.13
6.02
4.32
3.73
2.83
5.58
0.30
1.75
0.57
0.81
0.51
2.59
6.02
Model gth (%)
% Error exp vs model
72.39
70.69
70.13
69.32
68.26
67.40
67.08
65.19
63.84
Average
Max
0.33
2.51
1.09
1.21
2.84
0.86
2.67
2.15
2.41
1.79
2.84
Table 3
Comparison between Sandia experimental data [2] for a single-pass solar PTC with vacuum between receiver and cover and model developed
Case
1
2
3
4
5
6
7
8
9
Fluid
Water
Oil
Oil
Oil
Oil
Oil
Oil
Oil
Oil
Ib
(W/m2)
Flow rate
(1/min)
Wind speed
(m/s)
Tamb
(°C)
Tinlet
(°C)
exp DT
(°C)
Model DT
(°C)
% Error exp vs model
exp
807.9
933.7
968.2
982.3
909.5
937.9
880.6
903.2
920.9
18.4
47.7
47.8
49.1
54.7
55.5
55.6
56.3
56.8
1.0
2.6
3.7
2.5
3.3
1.0
2.9
4.2
2.6
15.8
21.2
22.4
24.3
26.2
28.8
27.5
31.1
29.5
18.3
102.2
151.0
197.5
250.7
297.8
299.0
355.9
379.5
17.8
21.8
22.3
22.0
18.7
19.1
18.2
18.1
18.5
17.79
21.25
22.94
21.67
18.19
18.85
17.61
18.40
18.83
Average
Max
0.23
2.51
2.86
1.49
2.75
1.30
3.24
1.67
1.77
1.98
3.24
72.63 ± 1.91
72.51 ± 1.95
70.90 ± 1.92
70.17 ± 1.81
70.25 ± 1.90
67.98 ± 1.86
68.92 ± 2.06
63.82 ± 2.36
62.34 ± 2.41
gth
circular heat exchangers is carried out in the following sections based on the single-pass model previously developed and validated.
In this section, the numerical algorithm and the mathematical formulation to solve the internal tube wall and fluid flow inside the annulus included in the new numerical model is presented.
Churchill [12] (Eq. (16)) with the hydraulic diameter, the convective heat transfer coefficient is calculated using the Monrad and
Pelton correlation developed specifically for flow in annulus (cited by Jakob [22]) that for the internal and external tube in the annulus are, respectively:
5.1.1. Spatial discretization
Fig. 5 shows half figures of the spatial discretization of two flow patterns of a solar PTC with counter flow concentric circular heat exchangers. The discretization nodes are located at the inlet and outlet sections of the CVs in the fluid flow zones, while the discretization nodes are centered in the CVs in the internal, receiver and cover tube wall. Each one of the fluids has been divided into nz volumes (i.e., nz + 1 nodes). The tube walls have been discretized into nz control volumes of length Dz.
Under this design conditions (Fig. 5), for flow pattern A before entering the internal tube for a double-pass operations the fluid
_
of mass flow rate (mÞ and the inlet temperature (Tin) will mix with
_
the fluid of mass flow rate (MmÞ exiting the annulus channel.
Counter current flow is achieved with the aid of conventional pump situated at the end of the inner channel and the mass flow rate then may be regulated. For flow pattern B, the inlet fluid may flow through the annulus with premixing the external recycle exiting from the inlet tube. In each flow pattern, the fluid is completely mixed at the inlet and outlet section of the tube.
Nu ¼ 0:02Re0:8 Pr1=3
5.1.2. Fluid flow inside the annulus
The same process developed for the fluid flow inside the receiver tube (Section 2.2) is carried out considering temperatures, area and roughness of both wall (internal and receiver tube wall).
The evaluation of empirical coefficients in this zone is as follow: the friction factor is evaluated from the expressions proposed by
0:53
Dr;int
Di;ext
Nu ¼ 0:027Re0:8 Pr 1=3
ð40Þ ð41Þ 5.1.3. Heat conduction in the internal tube wall
The same process developed for the receiver tube wall (Section 2.3) is carried out considering one-dimensional transient temperature distribution and negligible heat exchanged by radiation. Integrating the energy equation over the internal tube wall CV
(Fig. 2b), the following equation is obtained:
e oH ~
~
~
~
_
_
_
_
qs Ps À qn Pn Dz þ qw À qe At ¼ m ot ð42Þ
~
~
_
_
where qs and qn are evaluated using the respective convective heat transfer coefficient and fluid temperatures in each zone (fluid flow inside the internal tube and annulus), and the conductive heat fluxes
~
_ are evaluated from the Fourier law, that is: qe ¼ Àke ðoT wall =ozÞe and
~
_ qw ¼ Àkw ðoT wall =ozÞw .
Substituting their respective heat fluxes and rearrangement Eq.
(42), the following equation has been obtained for each node of the grid: aj T wall;j ¼ bj T wall;jþ1 þ cj T wall;jÀ1 þ dj where the coefficients are,
ð43Þ
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
605
Fig. 5. Schematic diagram of half figures of double-pass concentric circular heat exchangers with external recycle at both ends. Flow pattern A: before entering the internal
_
_ tube for a double-pass operations the fluid of mass flow rate ðmÞ and the inlet temperature (Tin) will mix with the fluid of mass flow rate ðM mÞ exiting the annulus channel.
Flow pattern B: the inlet fluid may flow through the annulus with premixing the external recycle exiting from the inlet tube.
kw At ke At
A t Dz kA qcp bj ¼ e t þ þ ðhs Ps þ hn Pn ÞDz þ
Dz
Dz
Dt
Dz
À
Á kw At
At Dz dj ¼ hs Ps T s þ hn Pn T n Dz þ qc p T o cj ¼ wall;j Dz
Dt
aj ¼
The coefficients mentioned above are applicable for 2 6 j 6 nz À 1; for j = 1 and j = nz adequate coefficients are used to take into account the axial heat conduction or temperature boundary conditions. The set of heat conduction discretized equations is solved using the algorithm TDMA [18].
5.2. Numerical solution of a double-pass solar PTC
At each time step solution process is carried out on the basis of a global algorithm (programmed in C language) that solves in a segregated manner the flow inside the internal tube, the flow inside the annulus and the heat conduction in the internal tube wall, the receiver tube wall, and the cover tube wall and finally the solar
PTC thermal analysis. The coupling between the six main subroutines has been performed iteratively each time step following the procedure (see Fig. 3):
For fluid flow inside the internal tube, the equations are solved considering the internal tube wall temperature distribution as boundary condition, and evaluating the convective heat transfer and fluid temperatures in each CV.
For fluid flow inside the annulus, the same process is carried out considering both wall temperatures and roughness (internal tube wall and receiver tube wall).
In the internal tube wall, the temperature distribution is re-calculated using the fluid flow temperature and the convective heat transfer coefficients evaluated in the preceding steps.
In the receiver tube wall, the temperature distribution is re-calculated using the fluid flow temperature and the convective heat transfer coefficient evaluated in the fluid flow inside the annulus, and considering the useful energy gain as boundary condition.
In the cover tube wall, the temperature distribution is calculated using the receiver tube wall, ambient and sky temperatures and the convective and radiative heat transfer coefficients between the cover and receiver and cover and sky and ambient.
The useful energy gain is obtained in terms of the thermal analysis carried out on the solar PTC, and the receiver tube and cover temperature distributions calculated in the previous steps.
The global convergence is reached when in two consecutive loops of the six main subroutines; a strict convergence criterion is verified for all the CVs in the domain.
5.3. Numerical results of a double-pass solar PTC
In Section 4, the single-pass solar PTC numerical model has been carefully validated with experimental data obtained by
Sandia National Laboratories [2] for air and vacuum between receiver and cover under different working conditions. In this section, the improvement using counter flow concentric circular heat exchangers for flow patterns A and B (Fig. 5) are evaluated using the same PTC specifications given in Table 1 and those ones given specifically for a double-pass solar PTC (Table 4).
The boundary conditions of case 11 (Table 2) with air and case
9 (Table 3) with vacuum in the space between receiver and cover have been selected as validated cases due to they have the highest thermal losses and hence the lower global thermal efficiencies. Parameters used in the cases evaluated numerically are: the solar PTC global thermal efficiency (Eq. (11)); Reynolds number
À
Á
À
Á
_
Re ¼ 4m=pDr;int l ; the channel thickness ratio K ¼ Di;int =Dr;int ; and the recycle ratio (M).
The improvement of solar PTC performance (ID) and the total friction power expenditure (PT) [23] are used as other performance parameters, which are calculated in the following form:
606
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
Table 4
Solar PTC specifications used for the double-pass device
Case 11, Table 2 (air between receiver and cover)
Channel thickness ratio (K)
Recycle ratio (M) a 920.9
2.6
29.5
379.5
17, 37, 57, 77, 97
(22.45, 26.67)
(36.62, 42.16)
(54.79, 60.33)
0.34, 0.55, 0.83
0.5, 1.0, 2.0
Solar beam irradiance (Ib) [W/m ]
Wind speed [m/s]
Ambient temperature (Tamb) [°C]
Inlet temperature (Tinlet) [°C]
Reynolds number (Re)x103
Internal tube diameters
(Di,int, Di,ext) [mm]a
Case 9, Table 3 (vacuum between receiver and cover)
898.6
2.8
29.7
376.6
20, 40, 60, 80, 100
2
(22.45, 26.67)
(36.62, 42.16)
(54.79, 60.33)
0.34, 0.55, 0.83
0.5, 1.0, 2.0
Commercial tubes available in stainless steel.
ID ¼
gth;new À gth;reference
 100 gth;reference ð44Þ
PT ¼
_
_
m1 Dp1 m2 Dp2 þ
q1 q2 ð45Þ
where subscript 1 and 2 indicate the flow inside the internal tube and annulus, respectively. In the case of single-pass only the first term appears.
5.3.1. Case of air between receiver and cover (double-pass device)
According to Fig. 6, the desirable effects of increases heat transfer and reducing surrounding thermal losses increases when the recycle ratio (M), channel thickness ratio (K) and Reynolds number rise. The reason why the desirable effect increasing when increasing the channel thickness ratio may be considered as the enhancement of convective heat transfer rate due to increasing the flow velocity in the annular channel, where the fluid is heated, is more effective than that in the inner channel. The validated case shown is the case 11 (Table 2).
A comparison of flow patterns A and B in Fig. 6 indicates an enhancement of global thermal efficiency occurs for flow pattern
B with design and operation parameters. The reason is again due
to flow velocities in the annular channel are higher in flow pattern
B than flow pattern A, that high flows are more effective that in the inner channel.
Fig. 7 shows that improvement of solar PTC performance for flow pattern B is obtained if the solar PTC is operated with a double-pass device in which the enhancement of convective heat transfer coefficient is provided. The advantages are evident with small Reynolds number and diminished when Reynolds number is increased. However for the validated case (case 11, Table 2) the improvement of solar PTC performance with a double-pass device and the same Reynolds number can be of approximately 3.2% and for lower Reynolds number this value can be higher than 10%.
The friction power expenditure increment calculated for the double-pass device is evident in Fig. 7; these values can be increased up to 2 to 3 orders of magnitude compared with the single-pass device. However, they can be still small because the friction power expenditure can be as small as 0.05 W for the validated case (single-pass). Losses of hundreds watts could be small in comparison with the energy gain by the fluid in the order of thousands of watts. The enhancement of heat transfer accompanies increase of hydraulic dissipated energy to maintain the extra
62
60
62
60
validated point
58
56
58
X
X
56
K=0.83
K=0.55
52
50
K=0.83
48
46
44
42
40
38
36
34
32
54
K=0.34
Global thermal efficiency [%]
Global thermal efficiency [%]
54
52
K=0.55
K=0.34
validated point
50
48
46
44
42
40
38
Flow pattern A
Flow pattern B
36
M=0.5
M=1
M=2
Double-pass without recycle
Single-pass device
30
20000 40000 60000 80000 100000
Reynolds number [dimensionless]
34
32
M=0.5
M=1
M=2
Double-pass without recycle
Single-pass device
30
20000 40000 60000 80000 100000
Reynolds number [dimensionless]
Fig. 6. Global thermal efficiency for a solar PTC with air between receiver and cover vs. Re with K and M as parameters (flow pattern A and B). Validated case (case 11, Table 2).
607
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
10
3
430
5
4
425
3
10
1
K=0.34
0
K=0.55
K=0.83
validated case
10-1
X
Flow pattern B
10-2
60000
0
X
Reynolds number [dimensionless]
K=0.34
415
410
K=0.83
-2
405
-3
validated case
-4
400
-5
395
-6
X
-7
390
-8
Flow pattern B
385
M=0.5
M=1
M=2
Double-pass without recycle
Single-pass device
Outlet temperature
-11
80000 100000
K=0.55
-1
-10
-3
40000
420
1
-9
M=0.5
M=1
M=2
Double-pass without recycle
Single-pass device
10
20000
2
Outlet temperature [oC]
10
Improvement of solar PTC performance [%]
Friction power expediture [W]
10
2
-12
20000
40000
60000
80000
380
375
100000
Reynolds number [dimensionless]
Fig. 7. Friction power expenditure, improvement and outlet temperature for a solar PTC with air between receiver and cover vs. Re with K and M as parameters (flow pattern
B). Validated case (case 11, Table 2).
friction loss. The evaluation of economical sense including the operating cost in the double-pass heat exchanger is necessary before take a decision to construct a solar PTC with counter flow concentric circular heat exchangers with or without recycle. However, the heat transfer advantage of the present double-pass devices under the same design and operating parameter is evident as compared with those in the single-pass device.
In Fig. 8, the receiver and fluid temperature distribution along the solar PTC is shown for the single-pass (validated case: case
11, Table 2), K = 0.55 double-pass without recycle and M = 1
K = 0.83 double-pass with recycle with the same boundary conditions. In this figure is shown that the surrounding thermal losses
450
Tf single-pass
Tr single-pass Flow pattern B
Tf K=0.55 double-pass without recycle
Tr K=0.55 double-pass without recycle
Tf M=1 K=0.83 double-pass
Tr M=1 K=0.83 double-pass
440
Temperature [oC]
430
420
receiver tube
410 annulus flow
400
internal flow
390
380
370
0
1
2
3
4
5
Distance [m]
6
7
Fig. 8. Fluid and receiver temperature distribution along the solar PTC for three cases with air between receiver and cover: single-pass, flow pattern B K = 0.55 double-pass without recycle and flow pattern B M = 1 K = 0.83 double-pass.
compared with the single-pass device are reduced for the case of
K = 0.55 double-pass without recycle and M = 1 K = 0.83 doublepass with recycle due to an important decrement in the receiver temperatures along the solar PTC. This is more evident for the last case (M = 1 K = 0.83) due to the mass flow rate is higher in the annulus and due to this the quantity of heat absorbed by the fluid is increased significantly compared with the other cases. The improvement of the solar PTC performance for the case of
K = 0.55 double-pass without recycle and M = 1 K = 0.83 doublepass with recycle are 1.44 and 3.28%, respectively. However, the friction power expenditure are 10.2 W and 177.24 W, respectively, and for a single-pass is 0.05 W. This additional operating cost and the cost of construct a double-pass device have to be taking into account before take a decision of construct a double-pass solar PTC.
5.3.2. Case of vacuum between receiver and cover (double-pass device) In these cases, the numerical model considered the convective heat transfer coefficient between the receiver and cover equal to zero. According to Fig. 9, the desirable effects of increasing heat transfer and reducing surrounding thermal losses increases when the recycle ratio (M), channel thickness ratio (K) and Reynolds number rise. Again as in the case of air between receiver and cover an enhancement of heat transfer rate occurs for flow pattern B with design and operation parameters.
A comparison between the numerical results obtained for air between receiver and cover (case 11, Table 2) and if it will have vacuum between receiver and cover showed that the global thermal efficiency are 56.83% and 63.84%, respectively, or the improvement in the solar PTC performance is 12.4% if vacuum exist between receiver and cover. For the case 7 with vacuum (Table
3) and if it will have air between receiver and cover the improvement obtained is 12.1%. Comparison between air and vacuum in the space between receiver and cover show that global thermal efficiency is significantly degraded by increasing thermal losses when air fills this space.
608
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
68
66
64
68 validated point
66
64
X
62
K=0.34
60
58
Global thermal efficiency [%]
Global thermal efficiency [%]
62
K=0.55
K=0.83
56
54
52
50
X
K=0.83
K=0.55
K=0.34
58
56
54
52
50
Flow pattern A
48
46
validated point
60
Flow pattern B
48
M=0.5
M=1
M=2
Double-pass without recycle
Single-pass device
M=0.5
M=1
M=2
Double-pass without recycle
Single-pass device
46
44
20000 40000 60000 80000 100000
Reynolds number [dimensionless]
44
20000 40000 60000 80000 100000
Reynolds number [dimensionless]
Fig. 9. Global thermal efficiency for a solar PTC with vacuum between receiver and cover vs. Re with K and M as parameters (flow pattern A and B). Validated case (case 9,
Table 3).
4
440
435
2
101
K=0.34
10
0
K=0.55
K=0.83
validated case
10-1
X
Flow pattern B
10-2
M=0.5
M=1
M=2
Double-pass without recycle
Single-pass device
-3
10
20000 40000 60000 80000 100000
Reynolds number [dimensionless]
Improvement of solar PTC performance [%]
Friction power expediture [W]
102
430
1
K=0.34
X
0
420
-1
-2
-3
425
K=0.55
K=0.83
415
validated case
410
-4
405
-5
-6
-7
-8
-9
-1 0
-1 1
400
X
Outlet temperature [oC]
3
3
10
395
Flow pattern B
M=0.5
M=1
M=2
Double-pass without recycle
Single-pass device
Outlet temperature
390
385
380
-1 2
375
20000 40000 60000 80000 100000
Reynolds number [dimensionless]
Fig. 10. Friction power expenditure, improvement and outlet temperature for a solar PTC with vacuum between receiver and cover vs. Re with K and M as parameters (flow pattern B). Validated case (case 9, Table 3).
Fig. 10 shows that improvement of solar PTC performance is obtained if the solar PTC is operated with a double-pass device in which the enhancement of convective heat transfer coefficient and consequent in the global thermal efficiency is provided. The advantages are evident with small Reynolds number and diminished when Reynolds number is increased. However for the vali-
dated case (case 9, Table 3) the improvement of solar PTC performance with a double-pass device and the same Reynolds number can be of approximately 2.5% and for lower Reynolds number this value can be higher than 10%.
The friction power expenditure increment calculated for the double-pass device is evident in Fig. 10. However, these values
O. García-Valladares, N. Velázquez / International Journal of Heat and Mass Transfer 52 (2009) 597–609
can be still small because the friction power expenditure can be as small as 0.05 W for the validated case (single-pass). The enhancement of heat transfer accompanies increase of hydraulic dissipated energy to maintain the extra friction loss. The evaluation of economical sense including the operating cost in the double-pass heat exchanger is necessary before take a decision to constructing a solar PTC with counter flow concentric circular heat exchangers with or without recycle.
In the same way, the decision between construct a solar PTC with air or vacuum between receiver and cover has to be taken with an economical evaluation of initial and operating cost.
6. Conclusions
A rigorous mathematical model considering the geometrical, optical, thermal and fluid dynamic aspects of a single-pass and double-pass solar PTC has been carried out.
The accuracy of the detailed simulation model is demonstrated in this paper by comparison for increment of temperature, thermal efficiency and thermal losses with steady state experimental data obtained by Sandia National Laboratories for a single-pass solar
PTC with air and vacuum in the space between the receiver and cover working with a single-phase water and thermal oil.
Twenty data points evaluated for thermal efficiency in both systems shown a maximum error of 6.02% with a mean deviation of
±2.19%. For the increment of temperature, the maximum error is
5.99% or 1.07 °C with a mean deviation of ±2.25% or ±0.41 °C.
The numerical model is based on the applications of governing equations and used general empirical correlations; for this reason, it is possible to make use of it with greater confidence to other fluids, mixtures and operating conditions (including two-phase flow); it allows using the model developed as an important tool to design and optimize these kinds of systems.
Numerical results shown that improvement in heat transfer is obtained if the solar PTC is operated with external recycle or with a double-pass without recycle. The desirable effects of increasing heat transfer and reducing surrounding thermal losses increases when the recycle ratio, channel thickness ratio and Reynolds number rise. However, the enhancement of heat transfer for doublepass device accompanies increase of hydraulic dissipated energy to maintain the extra friction loss. The evaluation of economical sense including the operating cost in the double-pass heat exchanger is necessary before take a decision to construct a solar PTC with counter flow concentric circular heat exchangers with or without
609
recycle or to decide if vacuum or air technology between receiver and cover is used.
References
[1] S.A. Kalogirou, Solar thermal collectors and applications, Prog. Energy
Combust. Sci. 30 (3) (2004) 231–295.
[2] V.E. Dudley, G.J. Kolb, A.R. Mahoney, T.R. Mancini, C.W. Matthews, M. Sloan, D.
Kearney, Test results: SEGS LS-2 solar collector, Report of Sandia National
Laboratories (SANDIA-94-1884), 1994.
[3] G. Cohen, D. Kearney, Improvement parabolic through solar electric system based on the SEGS experience, in: Proceedings of the ASES Annual Conference,
SOLAR 94, 1994, pp. 147–150.
[4] S. Kalogirou, S. Lloyd, J. Ward, Modelling, optimisation and performance evaluation of a parabolic trough solar collector steam generation system, Solar
Energy 60 (1) (1997) 49–59.
[5] S.D. Odeh, G.L. Morrison, M. Behnia, Modelling of parabolic through direct steam generation solar collectors, Solar Energy 62 (6) (1998) 395–406.
[6] S.D. Odeh, M. Behnia, G.L. Morrison, Hydrodynamic analysis of direct steam generation solar collectors, J. Solar Energy Eng. 122 (1) (2000) 14–22.
[7] S.D. Odeh, G.L. Morrison, Optimization of parabolic trough solar collector system, Int. J. Energy Res. 30 (4) (2006) 259–271.
[8] J.A. Duffie, W.A. Beckman, Solar Engineering of Thermal Processes, second ed.,
Wiley Interscience, New York, 1991. pp. 358–361.
[9] F. Kreith, M.S. Bohn, Principles of Heat Transfer, sixth ed., Thomson Learning,
2000.
[10] O. García-Valladares, C.D. Pérez-Segarra, J. Rigola, Numerical simulation of double-pipe condensers and evaporators, Int. J. Refrig. 27 (6) (2004) 656–670.
[11] V. Gnielinski, Equations for heat and mass transfer in turbulent pipe and channel flow, Int. Chem. Eng. 16 (1976) 359–368.
[12] S.W. Churchill, Frictional equation spans all fluid flow regimes, Chem. Eng. 84
(1977) 91–92.
[13] Z. Rouhani, E. Axelsson, Calculation of volume void fraction in the sub-cooled and quality region, Int. J. Heat Mass Transfer 13 (2) (1970) 383–393.
[14] O. Zürcher, J.R. Thome, D. Favrat, Evaporation of ammonia in a smooth horizontal tube: heat transfer measurements and predictions, J. Heat Transfer
121 (1) (1999) 89–101.
[15] F. Friedel, Improved friction pressure drop correlation for horizontal and vertical two-phase pipe flow, in: Proceedings of European Two-Phase Flow
Group Meeting, Ispra, Italy, 1979, paper E2.
[16] REFPROP v7.0, Reference fluid thermodynamic and transport properties, NIST
Standard Reference Database 23 Gaithersbug, MD 20800, 2002, USA.
[17] http://www.dow.com/heattrans/tech/data.htm.
[18] S.V. Patankar, Numerical Heat Transfer and Fluid Flow, Taylor & Francis,
London, 1980. pp. 52–54.
[19] B.V. Karlekar, R.M. Desmond, Engineering Heat Transfer, West Publishing Co.,
1977.
[20] S.W. Churchill, H.H.S. Chu, Correlating equations for laminar and turbulent free convection from a horizontal cylinder, Int. J. Heat Mass Transfer 18 (9) (1975)
1049–1053.
[21] C.D. Ho, S.C. Yeh, Improvement in device performance on laminar counterflow concentric circular heat exchangers with uniform wall fluxes, Int. J. Heat Mass
Transfer 49 (13–14) (2006) 2020–2032.
[22] M. Jakob, Heat Transfer, John Wiley & Sons, New York, 1949. p. 552.
[23] O. García-Valladares, Numerical simulation of triple concentric-tube heat exchangers, Int. J. Thermal Sci. 43 (10) (2004) 979–991.
References: Kearney, Test results: SEGS LS-2 solar collector, Report of Sandia National Laboratories (SANDIA-94-1884), 1994. SOLAR 94, 1994, pp. 147–150. Energy 60 (1) (1997) 49–59. [5] S.D. Odeh, G.L. Morrison, M. Behnia, Modelling of parabolic through direct steam generation solar collectors, Solar Energy 62 (6) (1998) 395–406. [8] J.A. Duffie, W.A. Beckman, Solar Engineering of Thermal Processes, second ed., Wiley Interscience, New York, 1991 [9] F. Kreith, M.S. Bohn, Principles of Heat Transfer, sixth ed., Thomson Learning, 2000. [12] S.W. Churchill, Frictional equation spans all fluid flow regimes, Chem. Eng. 84 (1977) 91–92. 121 (1) (1999) 89–101. Group Meeting, Ispra, Italy, 1979, paper E2. [16] REFPROP v7.0, Reference fluid thermodynamic and transport properties, NIST Standard Reference Database 23 Gaithersbug, MD 20800, 2002, USA. [18] S.V. Patankar, Numerical Heat Transfer and Fluid Flow, Taylor & Francis, London, 1980 [19] B.V. Karlekar, R.M. Desmond, Engineering Heat Transfer, West Publishing Co., 1977. Transfer 49 (13–14) (2006) 2020–2032. [22] M. Jakob, Heat Transfer, John Wiley & Sons, New York, 1949. p. 552.
You May Also Find These Documents Helpful
-
Brownson, J. (2014, May 25). Department of Energy and Mineral Engineering. Retrieved from Penn State University: https://www.e-education.psu.edu/eme810/node/593…
- 854 Words
- 3 Pages
Better Essays -
Active solar heating is a system of putting the sun's energy to use in which collectors absorb solar energy and pumps or fans distribute the collected heat. This functions in the manner that heat absorbed by a solar collector is transferred to a fluid inside the panel, which is then pumped to the heat exchanger, where the heat is transferred to water that will be stored in the hot water tank.…
- 655 Words
- 2 Pages
Good Essays -
Scientific and Technical Information, OSTI, U.S. Department of Energy. Oak Ridge National Lab, 19 Feb. 2009. Web. 02 Feb. 2012.…
- 1325 Words
- 6 Pages
Powerful Essays -
Despite what any individual’s concerns are regarding energy, it has been generally accepted that the finite source generating the majority of our electricity is depleting at alarming rates. We need to find alternative sources for energy production. The most obvious and abundant source available is the sun. Advances in technology have enabled us to harvest the solar radiation which has been conducting the cycle of life for millions of years. There are two main categories when it comes to solar power, passive and active. The passive solar systems integrate the sun’s energy to heat living spaces and/or water in a building. These system are very simple consisting few moving parts, require negligible maintenance and no mechanical components (Passive Solar Design). Passive…
- 3119 Words
- 13 Pages
Best Essays -
The transmittance () of a glass cover for solar radiation depends on the angle of incidence . Typical values for clear glass are given in Table 1.…
- 1662 Words
- 7 Pages
Good Essays -
ii. To investigate the efficiency of the heat exchanger in parallel and counter flow arrangements…
- 2580 Words
- 11 Pages
Powerful Essays -
In this report we will be discussing the Basic design, Material & Types of solar cooker,…
- 1995 Words
- 8 Pages
Powerful Essays -
Rodrigo Corral Franco1, Julián Peña Estrella2 Ingeniero Mecánico, 2MSc Facultad de Ingeniería Mecánica y Ciencias de la Producción Escuela Superior Politécnica del Litoral Km. 30.5 Vía Perimetral, Guayaquil, Ecuador rodrigoxcf@hotmail.com, jpena@espol.edu.ec…
- 3527 Words
- 15 Pages
Powerful Essays -
In HERO written, 25 technical questions/ 15 aptitude/ 10 english questions were there in 30 mins….…
- 267 Words
- 2 Pages
Satisfactory Essays -
The design concept is to use a black pipe to absorb heat from the sun light in order to heat the water flowing in the pipes. This solar hea9ng device is really simple and not complicated at all, and able to heat up water for anything and we will try to heat a swimming pool. Based on our analysis and prototype tes9ng, the design should be able to heat water up to 5 degrees or more.…
- 2594 Words
- 11 Pages
Better Essays -
A mathematical model which is investigated the thermal and physical behavior of a dish/Stirling system is presented, then the system was designed, analyzed and optimized. There are many types of heat losses in the dish/Stirling system, such as convection and conduction heat losses and radiation heat losses by emission in the cavity receiver and reflection heat loss of solar energy in the parabolic dish. There are also internal and external conduction heat losses, energy dissipation by pressure drops and energy losses by shuttle effect in displacer piston in the Stirling engine. All of these heat losses in the parabolic dish, cavity receiver and Stirling engine were calculated using mathematical modeling using MatlabTM software. For validation…
- 1308 Words
- 6 Pages
Good Essays -
Solar Concentrator Beam Quality................................... 21-9 Solar Concentration Ratio: Principles and Limitations of CSP Systems........................................... 21-13 Solar Thermal Power Plant Technologies ..................... 21-15 Parabolic Trough Solar Thermal Power Plants ............ 21-18…
- 47948 Words
- 192 Pages
Powerful Essays -
Mr. Jim Blanchard 2. The Following Students: a) b) c) d) e) f) g) Robert Deal Doug Sullivan Randy Heinrich Donna Wilson Shane Bertish Lonny Heinrich Bobby Mack I would also like to thank the Crosbyton Solar Power Project office and site personnel, and the Department of Energy for sponsoring the research (DE-AC04-83AL21667) contained within this report. u CONTENTS ACKNOWLEDGMENTS ii LIST OF TABLES v LIST OF FIGURES vi L INTRODUCTION 1 Alternative Energy Sources Solar Power Systems Membrane Spherical Concentrator n. 1 3 7 THEORY 13 Plate Deflection Membrane Deflection Evaluation Theoretical Focus 13 14 18 20 m. TECHNICAL APPROACH…
- 8529 Words
- 35 Pages
Good Essays -
The history of solar energy dates back two thousand seven hundred years. During that time period, people used glass lenses in order to ignite a fire. Greeks were the first people to use passive solar designs. They created buildings with southern-facing windows that allowed the sun to heat and light their homes. In the nineteenth century, a French physicist named Edmund Bequerel discovered that light energy could create a “photovoltaic effect.” A “photovoltaic effect” occurs when a device uses light from the sun to create an electric current. Solar cells were invented in the…
- 883 Words
- 4 Pages
Good Essays -
With the unlimited energy we receive from the sun, solar energy has the capabilities to meet the endless demand of energy and electricity both here in the United States and worldwide. Solar Energy is the one of a few energy sources that emits no carbon dioxide into the atmosphere at all. When comparing the cost and benefits of solar energy to other energy sources it is clear that solar energy is the most viable form of energy possible. With renewable energy becoming more and more of an issue, governments should utilize more funds to furthering the development of solar energy. Recently the cost of creating solar energy has drastically dropped which makes solar energy cost competitive in the energy market. Although there are some issues with the expansion and creation of solar plants, the benefits reaped would be worth the process.…
- 2162 Words
- 9 Pages
Best Essays