8
Heat Transfer Service Unit
Combined Convection & Radiation
Radial Heat Conduction
Heat Exchanger Service Unit
Shell and Tube Heat Exchanger
Linear Heat Conduction
Rising and Falling Film Evaporator
Steam
First Effect Rising Film
Second Effect Rising Film
Laboratory Steam Generator
Make &
Model
HT10XC
HT14
HT12
HT30XC
HT33
HT11
UOP20XSTM
UOP22-11
UOP22-22
UOP10-C
9
Heat Transfer Service Unit
H111
S. No.
1
2
3
4
5
6
7
10
11
Equipment
Thermal Conductivity of Liquid And
Gaseous Unit
Free and Forced Convection from Flat,
Dimmed and Finned Plates
H111H
H111P
12
Laminar / Viscous Flow Heat Exchanger
H971
13
Boiler Control Demonstration Unit
P7665+
P7667 PC
Manufacture
Qty
Armfield
Armfield
Armfield
Armfield
Armfield
Armfield
2
1
1
1
1
1
Armfield
1
Armfield
Armfield
Fulton
P.A Hilton
Ltd.
P.A Hilton
Ltd.
P.A Hilton
Ltd.
P.A Hilton
Ltd.
Cussons
Technology
1
1
1
1
1
1
1
1
HEAT TRANSFER SERVICE UNIT HT 10XC
The Armfield HT10XC is a service unit, which can be used in conjunction with a range of small scale accessories for a wide range of demonstrations into the modes of heat transfer.
The factors that affect heat transfer can be investigated and some of the practical problems associated with the transfer of heat can be clearly demonstrated.
The heat transfer accessories may be individually connected to the HT10XC service unit, which provides the necessary electrical supplies and measurement facilities for investigation and comparison of the different heat transfer characteristics.
A specific feature of the HT10XC is that it incorporates the facilities and safety features to allow the accessories to be remotely controlled from an external computer, where this is appropriate. With suitable (user provided) software, this means that the equipment can be operated remotely, for instance over an intra-net or even over the internet. All the facilities can also be accessed locally using the front panel controls and display.
Requirements
Single phase mains electrical supply:
HT10XC-A: 230V, 50Hz, @ 5A
HT10XC-B: 115V, 60 Hz, @ 10A
HT10XC-G: 220V, 60Hz, @ 5A
Shipping Specification
HT10XC only
Volume: 0.05m³
Gross Weight: 15kg
Overall dimensions
HT10XC only
Height: 0.24 m
Width: 0.32 m
Depth: 0.39 m
Computer Controlled Combined Convection and
Radiation
A hot surface loses heat (heat is transferred) to its surroundings by the combined modes of convection and radiation. In practice these modes are difficult to isolate and therefore an analysis of the combined effects at varying surface temperature and air velocity over the surface provides a meaningful teaching exercise.
The heated surface studied is a horizontal cylinder which can be operated in free convection or forced convection when located in the stream of moving air. Measurement of the surface temperature of the uniformly heated cylinder and the electrical power supplied to it allows the combined effects of radiation and convection to be compared with theoretical values. The dominance of convection at lower surface temperatures and the dominance of radiation at higher surface temperatures can be demonstrated as can the increase in heat transfer due to forced convection. On the HT14C, the heater power and the air flow are controlled via the HT10XC, either from the front panel, or from the computer software. On HT14 these are controlled manually.
OVERALL DIMENSIONS
HT14: HT14C:
Height: 1.20m Height: 1.20m
Width: 0.35m Width: 0.49m
Depth: 0.30m Depth: 0.44m
SPECIFICATION
HT14: HT14C:
Volume: 0.1m3 Volume: 0.2m3
Gross
weight:
9kg
Gross
Weight:
13kg
HT12C - Computer Controlled Radial Heat Conduction
The Armfield Radial Heat Conduction accessories have been designed to demonstrate the application of the Fourier Rate equation to simple steady-state conduction radially through the wall of a tube. The arrangement, using a solid metal disk with temperature measurements at different radii and heat flow radially outwards from the centre to the periphery, allows the temperature distribution and flow of heat by radial conduction to be investigated.
On the HT12C the heater power and the cooling water flow rate are controlled via the HT10XC, either from the front panel or from the computer software. On the HT12 these are controlled manually. ESSENTIAL ARMFIELD EQUIPMENT
HT12C requires HT10XC Computer Controlled
Heat Transfer Service Unit.
HT12 requires either HT10XC or HT10X Heat
Transfer Service Units.
SERVICES REQUIRED
Cold water supply: 1.5 litres/min @ 1 Barg
All electrical requirements are obtained from the service unit.
OVERALL DIMENSIONS
HT12: HT12C:
Height: 0.19m Height: 0.19m
Width: 0.35m Width: 0.43m
Depth: 0.18m Depth: 0.18m
SHIPPING SPECIFICATION
HT12: HT12C:
Volume: 0.03m3 Volume: 0.04m3
Gross weight: 5kg Gross Weight: 6kg
HT30XC Computer Controlled Heat Exchanger Service
Module
A range of small scale heat exchangers, designed to illustrate the principles and techniques of indirect heat transfer between fluid streams. Different types of heat exchanger can be mounted on a common bench-top service unit. Small scale versions of commonly used industrial heat exchangers are available (including plate, tubular and ‘shell and tube’) for analysis and comparison. The equipment is controlled by a user supplied personal computer, which serves as the operator interface. Full data logging, control and educational software is supplied with the equipment. In addition, the equipment has been fitted with failsafe systems, including a watchdog circuit, which allows for safe operation from a remote computer.
REQUIREMENTS
Single phase mains electricity supply:
HT30XC-A: 230V, 50Hz, 10Amp
HT30XC-B: 115V, 60Hz, 20Amp
HT30XC-G: 230V, 60Hz, 10Amp
Cold water supply and drain:
5 Litres/minute at 1bar Gauge (Min)
SPECIFICATION
Volume: 0.33m³
Gross weight: 33kg
DIMENSIONS
Height: 0.45m (service unit only)
Width: 1.0m
Depth: 0.5m
HT33 Shell & Tube Heat Exchanger
The shell and tube heat exchanger is commonly used in the food and chemical process industries. This type of exchanger consists of a number of tubes in parallel enclosed in a cylindrical shell. Heat is transferred between one fluid flowing through the tubes and another fluid flowing through the cylindrical shell around the tubes.
The miniature exchanger supplied is designed to demonstrate liquid to liquid heat transfer in a 1-7 shell and tube heat exchanger (one shell and 7 tubes with two transverse baffles in the shell). Specification
Volume: 0.06 m³
Gross Weight 5 kg
Armfield Accessories
HT30XC or HT30X Heat Exchanger Service Unit
Overall dimensions
Height 0.19m
Width 0.43m
Depth 0.39m
HT11 Linear Heat Conductor
The Armfield Linear Heat Conduction accessory has been designed to demonstrate the application of the Fourier Rate equation to simple steady-state conduction in one dimension.
The unit can be configured as a simple plane wall of uniform material and constant cross sectional area or composite plane walls with different materials or changes in cross sectional area to allow the principles of heat flow by linear conduction to be investigated.
Measurement of the heat flow and temperature gradient allows the thermal conductivity of the material to be calculated.
The design allows the conductivity of thin samples of insulating material to be determined.
Experimental Capabilities
• Understanding the use of the Fourier Rate Equation in determining rate of heat flow through solid materials
• Measuring the temperature distribution for steady-state conduction of energy through a uniform plane wall and a composite plane wall
• Determining the constant of proportionality (thermal conductivity k) of different materials
(conductors and insulators)
• Measuring the temperature drop at the contact face between adjacent layers in a composite plane wall (contact resistance)
• Measuring the temperature distribution for steady-state conduction of energy through a plane wall of reduced cross-sectional area
• Understanding the application of poor conductors (insulators)
• Observing unsteady-state conduction (qualitative only)
Armfield equipment
HT10X Heat Transfer Service Unit
Armfield Accessories
HT10X-304 Educational Software with USB interface
Requirements
Cold water supply:
1.5 litres/min @ 1 Barg
Specification
Volume: 0.04m³
Gross weight: 5kg
Overall dimensions
Height: 0.29m
Width: 0.43m
Depth: 0.21m
UOP20X Modular Evaporator Series
The UOP20 family is a modular system of teaching evaporators for chemical engineering departments. Using the various modules a wide range of configurations can be implemented: rising; single or double effect; forward, backward or parallel feed.
The evaporators are fully computer compatible, supplied with educational software including process control and data logging facility, suitable for use with a personal computer.
Evaporator Service Unit (UOP20X)
The Evaporator Service Unit (UOP20X) contains all the services and facilities to implement a laboratory evaporation system. It comprises a feed pump and pre-heat system, vacuum pump, condenser, collection vessels and control console containing a full set of instrumentation, all mounted in a sturdy steel framework.
Two mounting positions are provided for the modular evaporation columns.
Two basic variants of the UOP20X are available, dependent on whether it is required to use steam as the process heating source or pressurised hot water:
The UOP20X-STM includes a steam control valve and steam pressure gauge. It is powered from an external steam source such as the Armfield UOP10 or any other suitable laboratory steam supply.
The UOP20X-PHW includes a pumped recirculating pressurised hot water system complete with integral 3 term temperature controller. Therefore service requirements are simply an appropriate electrical supply and a cooling water supply.
Each UOP20X includes a control console, containing all of the electrical components, controls and displays for the evaporator. Twelve process temperatures, three conductivity readings and the vacuum level can be displayed.
It also includes pre-heat temperature controller, speed controls for the feed pump and recirculation pumps, the computer interface and electric mains switching controls.
When coupled to a suitable PC, using the two USB interfaces, a wide range of sophisticated data logging and educational software facilities is available. Furthermore the UOP20 can be operated in remote control mode, whereby the majority of the control panel functions can be implemented directly from the PC. Although a wide range of products may be concentrated in the evaporator, the software includes algorithms so that when potassium chloride is used the computer display indicates the product concentrations directly. These are calculated in real-time from the temperature and conductivity readings. The computer software also includes a fully configurable PID controller for performing process control experiments.
The vacuum pump and display can be used to show the effect of vacuum on evaporation temperature. In a double effect system the vacuum is applied to the second stage.
Evaporator Columns
Each evaporator column contains a stainless steel evaporation tube, within an insulated heated jacket for the hot water or steam. These are mounted on a back plate together with a glass cyclone to separate the concentrated product from the evaporated steam.
Also included on the back plate of each evaporation column is a recirculation pump and associated pipework, together with thermocouples to measure the temperatures of the product and heating fluid at a number of points. Two basic types of evaporation column are available:
UOP22, a rising film evaporation column.
A number of variants are defined for each column type, dependent on whether it is a first or second effect unit, and whether it is located in the first or the second position on the UOP20X service unit.
UOP22-11 Rising Film Evaporation Column (1st effect, 1st position)
UOP22-22 Rising Film Evaporation Column (2nd effect, 2nd position)
OVERALL DIMENSIONS
Height: 2.5m
Width: 1.5m
Depth: 0.9m
SPECIFICATION
UOP20X: including up to two evaporation columns:
Volume: 5m3
Gross weight: 450Kg max.
Evaporator Column Length: 1m
Pressurised Water Heater: 4KW
Feed Pre‐Heater: 2KW
Conductivity displays: 0‐100mS
HEAT TRANSFER SERVICE UNIT H111
It is essential that the three basic modes of heat transfer; Conduction, Convection and Radiation are understood by students as a foundation for further studies involving heat transfer and temperature measurement. The Hilton Heat Transfer Service Unit H111 may be connected to any of seven optional demonstration units each demonstrating a fundamental mode of heat transfer or a combination of modes of heat transfer and a range of experiments to reinforce the learning process.
The Hilton Heat Transfer Service Unit H111 is bench mounted, operates from a conventional singlephase electrical power supply and provides both control and instrumentation for each of the seven optional demonstration units.
The seven optional units are: Linear Heat Conduction
Radial Heat Conduction
Laws of Radiant Heat Transfer & Radiant Heat Exchange
Combined Convection and Radiation
Extended Surface Heat Transfer
SPECIFICATION
Electrical Specification
Either: A:
B:
220-240 Volts, Single Phase,
50Hz(With earth/ground).
110-120 Volts, Single Phase,
60Hz(With earth/ground).
Service Unit
Net Weight: 12.3 kg.
Packing Case Volume: 0.22m3
H111A
H111B
H111C
H111D
H111E
FREE AND FORCED CONVECTION FROM FLAT,
PINNED AND FINNED PLATES H111P
A bench top accessory designed to allow students to experimentally investigate both free (natural) convection and forced convection. The accessory includes a small, variable velocity wind tunnel with a digital velocity meter and a central aperture. Three plates with integral heaters and temperature sensors are also supplied that are designed to fit in the central aperture in the wind tunnel.
A heated flat plate with surface thermocouple may be directly compared with a similar pinned plate and finned plate also fitted with a surface thermocouple. In addition to expanding understanding of the heat transfer enhancement from extended surfaces, the pinned and finned plates each have three thermocouples arranged at intervals along a fin and a pin. This allows investigation of the temperature distribution along the extended surfaces.
SPECIFICATION
Net Weight
30kg
Packing Case Volume 0.28m3
DIMENSIONS
Height: 1300mm
Depth: 300mm
Width: 350mm
Weight: 20kg.
BOILER CONTROL DEMONSTRATION AND FAULT
SIMULATOR UNIT
The Cussons P7665 Boiler Control Demonstration Unit has been designed to demonstrate clearly and simply a range of boiler control sequences relating to oil or gas fired boilers. Since steam pressure is
‘simulated’ the whole functioning of a boiler may be studied in a relatively safe situation. The
Demonstration Unit can act as a valuable teaching aid for the training of boiler operating personnel in the diagnosis of boiler system faults which may occur in practice.
FAULT SWITCH FUNCTIONS
Switch Fault
A Blower motor failure
B Ignition transformer failure
C Pilot flame solenoid failure
D Main flame solenoid failure
E Power failure
F Ignition circuit fuse failure
G Pressure gauge system fault
H Feedwater pump fault
I Pump fuse failure
J Pressure switch failed open
K Pressure switch failed closed
M Closed electrode probe short circuited
N Photocell operation fault
Specifications
Gross weight: 410 kgs
Nett weight: 220 kgs
Case size: 134 x 96 x 193 cm
You May Also Find These Documents Helpful
-
Equipment within the office needs to be used following any guidelines from the manufacturer/organisation to eliminate any risks of somebody harming themselves and to keep any equipment in good condition.…
- 484 Words
- 2 Pages
Satisfactory Essays -
"Our system will provide a full LAN configuration for your customer support services area covering the major areas of functionality required including: call logging by customer or inquirer, recording of nature of request and nature of response, access to all company technical literature online, and automatic message forwarding to hand-held devices of field service persons where necessary. The cost of the system includes the required file server and six workstations, laser printer and WAN communications adapter ($150,000). The…
- 682 Words
- 3 Pages
Satisfactory Essays -
The heat transferred from hot water to cold water is due to their potential (temperature) difference.…
- 1398 Words
- 6 Pages
Good Essays -
Measurements were relatively accurate and closely linked to quantitative values. When measurement was a little higher, value resulted a little higher. The Styrofoam for this experiment was necessary because it insulates leading to less energy loss to the surrounding of the system. Because there was a change in temperature from the initial and final results, there cannot be an assumption that there was no heat exchange with the surroundings. To improve accuracy of result from this experiment, a better calibration and calorimeter may be used to reduce the amount of heat absorbed during the process.…
- 286 Words
- 2 Pages
Satisfactory Essays -
The corporate main office is in Ohio. The office at this location uses Avaya Digital Phone System and is connected to a Cisco 10 MB Hub. All equipments in this location get access to the Avaya Digital Phone System through the 10 MB Hub. The plant at the Ohio location has set up different workstations; each workstation has a wireless bar code, scanner, shipper, and telephone.…
- 758 Words
- 3 Pages
Good Essays -
4. Compare the values for heat gain and heat loss in questions 2 and 3.…
- 508 Words
- 2 Pages
Satisfactory Essays -
We also need to understand the specifics of combustion, which is the chemical process of burning specific compounds and other items, and the specific heat capacity - the amount of thermal energy needed to increase the temperature of a given substance. Furthermore, determining the heat of combustion to compare to the values of other hydrocarbons - elements made entirely out of hydrogen and carbon - is very useful for the reasons listed above. As we know, the measurement of the quantity of heat exchanged of any type of thermal energy released is known as calorimetry - an entirely different science than we are used to. We are using each of these concepts throughout the lab experiment and are continuing to further our knowledge of each as…
- 541 Words
- 3 Pages
Good Essays -
Heat, also called thermal energy, can be transmitted through space (radiation), by moving fluids (convection), or through direct contact. This final method, called conduction, is explored in the Heat Transfer by Conduction Gizmo™.…
- 837 Words
- 4 Pages
Satisfactory Essays -
Apply concepts of temperature and heat as energy to solve problems concerning the transfer of heat and effects of heat on systems.…
- 2190 Words
- 9 Pages
Powerful Essays -
In the engineering sciences, heat transfer includes the processes of thermal radiation, convection, and sometimes mass transfer and often more than one of these processes occurs in a given situation.Shaun Prado 8F…
- 648 Words
- 3 Pages
Satisfactory Essays -
and then from the cup to the material around it. If the material is a…
- 1646 Words
- 7 Pages
Powerful Essays -
• Understand the Fourier Law of heat conduction and the usage of its equation in determining the rate of heat flow via solid materials.…
- 927 Words
- 4 Pages
Good Essays -
TECHNICAL SPECIFICATION: Condensers : One chromium plated for drop wise condensation & one natural finish for Film wise condensation otherwise identical in construction. 19 mm outer dia. 170 mm length. Fabricated from copper with reverse flow in concentric tubes. Fitted with temperature sensor for surface temp Measurement. M.S. Fabricated construction comprising test section & steam generation section. Test section provided with glass cylinder for visualization of the process. Suitable water heater. 1) Temperature Indicator: Digital 0-199.9 ° C with multichannel switch. 2) Temperature Sensors : RTD PT – 100 Type 3) Rota meter for measuring water flow rate. 4) Pressure Gauge: Dial type 0-2 Kg/cm2…
- 311 Words
- 2 Pages
Good Essays -
The overall heat transfer coefficient U for gases around 1bar in literature1 is approximately a value between . On first approximation the value is used in this case.…
- 609 Words
- 4 Pages
Satisfactory Essays -
• The transfer of energy as heat is always from the highertemperature medium to the lower-temperature one.…
- 2998 Words
- 23 Pages
Good Essays