Transport and storage
6.2 Product storage vapor state corrosion inhibitors (VSI 8235), and external protection in the form of temperatures for about 12 months.
6.2.1
DANGER
Unsecured motor can fall!
Danger to life or risk of injury, damage to equipment! falling. CAUTION
Incorrect placement of the motor!
Risk of damage to equipment.
When in storage with shaft vertical, the motor must always be placed with the hollow shaft facing down.
It is also advisable to provide supports att the mounting surface of the motor,
its outer diameter or on the suitably protected end face of the hollow shaft. It is also surface. A) Standing with
B) Standing with
shaft horizontal
shaft vertical
Support
Fig. 12:
RE 15300-WA, Installation and maintenance manual for Hägglunds CBM, Bosch Rexroth Mellansel AB
Transport and storage
33/74
6.2.2 Storing for extended periods or in uncontrolled environment
If the motor is stored for more than 3 months in uncontrolled environment or more
1
2
3 Take extreme care to ensure that no contamination enters the motor.
4
delivery. Check that the O-rings or rubber seals are in position in the cover plate.
5 Fit the plug to D1.
6
B) Standing with shaft vertical.
Table 18: Oil volume
Motor
Oil volume approx.
Litres
US gal.
CBM 2000
50
13,2
CBM 3000
70
18,5
CBM 4000
90
23,8
CBM 5000
110
29,0
CBM 6000
130
34,3
F2
Fig. 13: Filling the motor with oil
Bosch Rexroth Mellansel AB, Intallation and maintenance manual for hägglunds CBM, RE 15300-WA/03.2013
34/74
Assembly
6.2.3 Storing during maintenance it can be stored up to one month, without additional rust protection. After one
Use 2% of Shell VSI
This additive gives rust protection for up to about 3 month in uncontrolled environment or more than 12 months in controlled environment.
If no additives are used, the motor must be turned a few revolutions once a month