Heat Pump ------------------------------------------------- A heat pump can provide an alternative to using your air conditioner. * Heat pumps can supply heat‚ cooling‚ and hot water. * Your climate and site will determine the type of heat pump most appropriate for your home. For climates with moderate heating and cooling needs‚ heat pumps offer an energy-efficient alternative to furnaces and air conditioners. Like your refrigerator‚ heat pumps use electricity to move heat from a
Premium Heat pump
machinery problem. We intend to do a project on “Vibration analysis of centrifugal pump at BPCL Kochi Refinery”. The vibration analysis we have done is a part of predictive maintenance on rotary equipments. This technique is mainly used for the improved performance of equipments. Using this we can predict the condition of internal parts of the equipment. We are mainly dealing with the vibration analysis of centrifugal pump‚ compressors and motors. It includes typical causes of vibration like misalignment
Premium Petroleum Oil refinery
Pumps Selection‚ Operation & Maintenance Dr. M.F. Khalil Professor Mech. Eng. Dept. Alexandria University Alex.Eng.Society Short Course By MFKhalil 1 Pumps Function Classification Construction‚ Theory ‚ Operation & Applications Alex.Eng.Society Short Course By MFKhalil 2 Pump Pump is a mechanical device which • converts mechanical energy of its driving unit ( electric motor‚ diesel engine‚ steam turbine ‚gas turbine ‚wind turbine.. Etc.) to hydraulic energy .This hydraulic energy
Premium Pumps Fluid dynamics Pressure
CENTRIFUGAL PUMPS Introduction A centrifugal pump is a rotodynamic pump that uses a rotating impeller to create flow by the addition of energy to a fluid. Centrifugal pumps are commonly used to move liquids through piping. The fluid enters the pump impeller along or near to the rotating axis and is accelerated by the impeller‚ flowing radially outward into a diffuser or volute chamber (casing)‚ from where it exits into the downstream piping. Centrifugal pumps are used for
Premium Force Fluid dynamics Classical mechanics
Electrical Submersible Pump Analysis and Design May 30‚ 2001 Electrical Submersible Pump Analysis and Design Case Services‚ Inc. Abstract Case Services’ software provides production optimization for a variety of different methods of artificial lift. This paper discusses the dominant factors in electrical centrifugal submersible pump design and monitoring. Emphasis is placed on three areas: • • • Well inflow performance behavior. Fluid Pressure-Volume-Temperature and phase behavior. Pump equipment performance
Premium Pumps Fluid dynamics
Submersible Pump Application The system consists of a submersible pump controlled by a Danfoss VLT AQUA Drive and a pressure transmitter. The transmitter gives a 4-20 mA feedback signal to the VLT AQUA Drive‚ which keeps a constant pressure by controlling the speed of the pump. To design a drive for a submersible pump application‚ there are a few important issues to take into consideration. Therefore the drive used must be chosen according to motor current. 1. The motor is a so called “Can motor”
Premium Electric motor
Centrifugal Pump @ 1750 RPM · Figure 1 Head Pressure versus Flowrate · Figure 2 Ideal Power versus Head Pressure (H) · Sample Calculations · Raw Data Discussion of Experiment A centrifugal pump contains an impeller or set of vanes encased in housing. Energy is added to the fluid in the form of velocity and pressure as a result of the impeller turning. An engineer must determine the range of flow rates required when using a centrifugal pump. The centrifugal
Premium Fluid dynamics Volumetric flow rate
TUTORIAL CENTRIFUGAL PUMP SYSTEMS by Jacques Chaurette p. eng. copyright 2005 Fluide Design Inc.‚ 5764 Monkland avenue‚ Suite 311‚ Montreal‚ Quebec‚ Canada H4A 1E9 Tel: 514.484.PUMP (7867) E-mail: jchaurette@fluidedesign.com Web site: www.fluidedesign.com page….2 Table of contents 1. Different types of pump systems 2. Three important characteristics of a pump system: pressure‚ friction and flow 3. What is friction in a pump system 4. Energy and head in pump systems 5. Static head 6. Flow rate
Premium Fluid dynamics Pressure Atmospheric pressure
consider a multiple pump system to meet the design requirements. Two typical options include parallel and series configurations of pumps. Specific performance criteria must be met when considering these options. Given a piping system which has a known design flow rate and head requirements‚ Qdes‚ hdes‚ the following pump selection criteria apply. Pumps in Parallel: Assuming that the pumps are identical‚ each pump must provide the following: Q(pump) = 0.5 Qdes h(pump) = hdes Pumps in Series: Assuming
Premium Wind turbine Wind power Energy
PDHonline Course M102 (2 PDH) Selecting a Centrifugal Pump to Handle a Viscous Liquid Instructor: Randall W. Whitesides‚ PE 2012 PDH Online | PDH Center 5272 Meadow Estates Drive Fairfax‚ VA 22030-6658 Phone & Fax: 703-988-0088 www.PDHonline.org www.PDHcenter.com An Approved Continuing Education Provider www.PDHcenter.com PDH Course M102 www.PDHonline.org Selecting a Centrifugal Pump to Handle a Viscous Liquid Copyright © 2002-2011 Randall W. Whitesides‚ P.E.
Premium Viscosity