Replacement Reactions (Data and Calculations) Objective: Classify the chemical reaction through observation‚ which each reagent produce when mixed with another reagent. After careful observation‚ be able to prove each observation using the net ionic equation. Background: First‚ a double-replacement reaction is when two cations in different compound switch anions‚ AX + BZ → BY. If either compounds are insoluble a precipitate occurs‚ and if there is no precipitate formed there is no reaction. Also‚
Premium Chemical reaction Chemistry Sodium
Thermochemistry Lab Hypothesis We predict that two different physical changes (dissolving of a chemical substance in water) will produce energy changes; one exothermic and one endothermic. We predict that the temperature change will be affected by the change in system (open vs. closed) will be as follows: the temperature change in the closed system will be greater than that of the open system. Materials Refer to attached sheet Method Refer to attached sheet Observations Substance Added
Premium
Gas Laws Lab Introduction: The four basic physical properties of a gas sample are pressure‚ volume‚ temperature‚ and number of moles. The volume simply indicates the volume of the container since a gas will take up all space available to it. The temperature indicates the average kinetic energy of the gas particles. For gases‚ the temperature must be converted to the Kelvin unit. The pressure of the gas indicates the number of collisions with each other and the wall of the container. The number
Premium Gas Pressure Ideal gas law
I2 No reaction‚ starch will remain white Reaction; black deposits on the glass tube. Starch turns black Food coloring + NaOCl No reaction; will turn lighter Reaction; the solution that was dark blue turned into light blue Food coloring + CH3COOH No reaction; color will turn lighter No reaction; when both combined‚ the color (dark blue) remained the same Food coloring + NaOCl + CH3COOH No reaction; solution will remain blue Reaction; solution turns light gray Red cabbage + NH3 No reaction; solution
Premium Chemistry Chemical reaction Sodium
Erica Chan Sinh Nguyen Dat Nguyen Wed 2:00-5:00 02/19/2014 OHM’S LAW I. Purpose The purpose of this lab is to help understand how voltage‚ current and resistance are closely related to one another. The outcome from this lab is to be able to differentiate when to use ohmmeter and voltmeter for the individual circuit. II. Theory Ohm’s Law states that the electric current through a material is directly proportional to the voltage across a piece of material (such as wire) while the resistance is held
Premium Electrical resistance Resistor Ohm's law
Willy Rupprecht Date(s) performed: October 2 - 3‚ 2012 Gravimetric Analysis of an Unknown Group 1 Metal Carbonate Purpose: The purpose of this lab is to determine the identity of a Group 1 metal carbonate compound by gravimetric analysis. Procedure: The unknown carbonate is weighed and then dissolved in water. A solution of CaCl2 (calcium chloride) is added to the metal carbonate solution to precipitate the carbonate ions as CaCO3 (calcium carbonate). The precipitate is then filtered‚ dried
Premium Calcium Filter paper Gravimetric analysis
Diels-Alder Reaction Heather Jost Lab Partner: Jasmina Salcinovic CHEM2642L Luise Strange de Soria Georgia Perimeter College September 29‚ 2004 Diels-Alder Reaction Resources: Mayo‚ Pike‚ Trumper‚ Strange de Soria. Microscale Organic Laboratory. New York: John Wiley and Sons‚ 2002. Strange de Soria‚ Luise. “Student Survival Guide”. http://www.gpc.edu/~lstrange/2642lab/survivalguide/grignard2.pdf. 2004. Purpose: The purpose of these experiments
Premium Chemistry Chemical reaction Experiment
Objective: The purpose of the lab is to learn filtering techniques. Specifically‚ to form and filter a calcium carbonate precipitate using a Buchner funnel. Procedure: a.) Prepared a mixture of .5 M calcium nitrate (45 mL) and .01 M sodium carbonate by combining and stirring the two liquids in a beaker. Allow the mixture to stand. b.) Prepare the filtration assembly. The assembly consists of a tapered flask with a buchner funnel inserted in the top. The funnel has a rubber stopper attached
Premium Laboratory glassware Water Solid
since a type II product is essentially the result of a homolytic cleavage of the Fe-S bond from a type I product.2 Type II products are not thermodynamically stable without a second equivalent of H2S‚ which complexes with the sulfide radical to create an H2S2•- species.2 This type of reaction can continue to create polysulfide chains.2 Lastly‚ type III reactions
Premium Hydrogen Oxygen Atom
DEPARTMENT OF PURE AND APPLIED CHEMISTRY College of Art and Sciences Visayas State University Chemistry 31a Biochemistry Laboratory Experiment No. 09 CHEMISTRY OF URINE Name: Artajo‚ Zeal Conbrio A. DVM-2 Date performed: Feb. 26‚ 2013 Group: 6 Date submitted: March 5‚ 2013 Objective: 1. Test urine for pH‚ specific gravity‚ and the presence of electrolytes and organic compounds. 2. Test
Premium Uric acid Urine Ammonia