Titration Analysis of Vinegar Student: Araik Movessian Grade: 12 Course: SCH4U Teacher: Tijana Knezovic Purpose and Introduction: In this experiment the question of “what is the molar concentration of acetic acid in a sample of vinegar?” was answered via titration using a standard solution of sodium hydroxide‚ NaOH(aq). In this investigation‚ students are to act as quality control chemists. Their purpose is to test the acetic acid concentration of the vinegar to discover whether it
Free Titration Laboratory glassware Sodium hydroxide
Hardness Using a Titrator Purpose: To become familiar with the concept of water hardness‚ practice a titration technique using a titrator‚ and determine the hardness of the local water supply. Procedure: 1. Gather the test tube holder‚ small stopcock‚ 10-mL syringe (titrator)‚ and 2 thick textbooks and the LabPaq box or 5-6 thick textbooks. 2. Remove the plunger from the titrator and place it back in your LabPaq box. 3. Attach the stopcock to the tip of the titrator by placing the larger‚ clear
Premium Water Water supply Towel
Estimation by back(idiometric) titration Mahindra (UWC of India) Chemistry lab report for back titration Name: Ashenafi Asfaw Beyene Back (Indirect) Titration Vitamin C estimation by Back Titration Table1: The amount of volume (in cm3) and concentration (in M) of KI‚ KIO3‚ and H2SO4 which were used in the experiment of Vit C estimation by back titration
Premium Titration Vitamin C Iodine
Thornton James Keel 7/20/13 Title: Titration for Acetic Acid in Vinegar Purpose: The objectives in this lab were to develop familiarity with the concepts and techniques of titration and to determine the concentration of an acetic acid solution in vinegar. Procedure: Data Tables: Data Table 1: Quantity of NaOH needed to Neutralize 5 mL of Acetic Acid Brand of Vinegar Used: heinz Label Notes: none | | Initial NaOH reading(Interpolate to 0.1 mL) | Final NaOH reading(Interpolate
Premium Acetic acid Ethanol Sodium hydroxide
Objective: To determine the content of vitamin C in commercial tablets (redox titration and back titration) Principle of method: Vitamin C‚ which is ascorbic acid‚ reacts with iodine rapidly in an acidic medium. C6H8O6 (aq) + I2 (aq) C6H6O6 (aq) + 2H+(aq) + 2I- (aq) Since iodine dissolves slightly in water‚ ascorbic acid cannot be titrated directly by a standard solution of iodine. Therefore‚ back titration technique is employed in this experiment. In an acidic medium‚ potassium iodate(V)
Premium Iodine Vitamin C Titration
CHAPTER 1 EXECUTIVE SUMMARY 1 This project focuses on the growth of Calcium supplement segment over two decades. This project gives us an insight into the dietary segment of pharmaceutical industry particularly the calcium supplement segment. The project is started with the introduction of Indian pharmaceutical industry and it‘s growth from three decades. Moreover in this project‚ the rising importance of patents & its effects (advantages & disadvantages) on the pharmaceutical industry
Premium Pharmaceutical industry Vitamin D Calcium
Phuong Pham Prof. Johnson Lab 3 Gravimetric determination of Calcium as CaC2O4.H2O Feb‚ 27‚ 2014 I. Objective: The purpose of this lab is to determine how well gravimetric method measures the calcium level in a solution of known calcium concentration. II. Method: a) Overview: In this lab we will prepare 25 mL known concentration Calcium solutions. Then we will use Gravimetric method to determine the concentration of Calcium in each solution to figure out how well this method is. As we know
Premium Arithmetic mean Gravimetric analysis Variance
the Solubility of Calcium Hydroxide Apparatus * Solid calcium hydroxide * 0.4 mol/dm hydrochloric acid * Distilled water * Pipette * Triple valve rubber pipette filler * Conical flask * Beaker * White tile * Clamp and stand * Methyl orange indicator Producing the calcium hydroxide solution 1. Roughly fill a beaker with 200cm³ of distilled water. This does not need to be accurate because samples will be taken from this. 2. Add solid calcium hydroxide‚ a spatula
Free Titration Laboratory glassware PH indicator
2. Preparation Of 1 M Na2CO3 Molecular mass of Na2CO3 = 106g Mass of salt in 100 ml of 1M solution = 10.6g Weighing of salt using electrical balance * Mass of Na2CO3 + beaker = 78.64g * Mass of beaker = 68.04g * Mass of Na2CO3 = 10.6g 1. 10.6g of Na2CO3 was weighed in a dry beaker. Small amount of distilled water was added and the salt was dissolved. 2. The contents of the beaker were transferred to
Free Laboratory glassware Titration Iodine
E r J. Biochem. 40‚177-185 (1973) u. Intracellular Titration of Cyclic AMP Bound to Receptor Proteins and Correlation with Cyclic-AMP Levels in the Surviving Rat Diaphragm Lien DO KHAC‚Simone HARBON Hubert J. CLAUSER and lnstitut de Biochimie‚ Universit6 de Paris-Sud‚ Orsay (Received April 9/July 17‚ 1973) Extracts prepared from rat diaphragms incubated with or without theophylline and/or epinephrine have been tested for their total cyclic AMP content and for their ability to bind exogenously
Premium Protein Signal transduction