| | | CP-24 V-BLOCK Go to CALIBRATION PROCEDURE HOME or INDEX for links to other procedures.V-BLOCKS V-Blocks are often used to check true position gages and runout in the lab. They are also used for work holding and inspection on the shop floor. In some shop work holding applications‚ the accuracy would not need to be to the level of lab or inspection gage blocks. V-blocks are precisely square‚ and the V-groove should be in the exact center of the block. The prime purpose of a V-block is to
Premium Angle Surface
CALIBRATION OF TEMPERATURE AND PRESSURE SENSORS Mechanical Engineering Department Loyola Marymount University Los Angeles‚ California ABSTRACT In this laboratory experiment‚ an Omega Model PX- 236-060GV piezoresistive pressure transducer was calibrated‚ by using an AMTEK model deadweight pressure tester. For the temperature calibration an Jofra Model C-140 temperature calibrator was used. The experiment began by setting up the Jofra Model C-140 temperature calibrator‚ and taking data from
Premium Measurement Metrology
PRESSURE MEASUREMENT AND CALIBRATION YEDĐTEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING 1 YEDITEPE UNIVERSITY ENGINEERING FACULTY MECHANICAL ENGINEERING LABORATORY Pressure Measurement and Calibration 1. Objective: To convert an arbitrary scale of pressure sensor output into engineering units. To calibrate a semiconductor pressure sensor. 2. Equipment: The equipment comprises a Dead-weight Pressure Calibrator (DPC)‚ Bourdon gauge and diaphragm-type pressure sensor. The
Premium Pressure Atmospheric pressure
H_2 The purpose of this experiment is to determine the mass % of through the Volumetric Analysis method. To attain this purpose‚ a decomposition reaction was performed‚ which can be separated into two steps. First‚ 2 mL of was reacted with approximately .5 g of KI in an Erlenmeyer flask to form and a hypoiodite species. The second step is the reaction between another molecule of and hypoiodite‚ which results in reformation of the catalyst‚ potassium iodide. The catalyst is used to speed up
Premium Chemical reaction Chemistry Chlorine
must both equal (in this case 1:1) in order for the calculation to find the molar mass to work. Procedure: Begin the procedure by first making sure all glassware has been cleaned. Next set up the buret for the titration using the same method as week 1. Similar to week 1 the titration is performed using NaOH as a base in the solution so the buret should filled with the NaOH and the initial volume may be recorded. The acid (acetic acid) should be mixed in solution with 5.00 mL of acid and 50.0 mL of
Premium Acetic acid Vinegar Concentration
Kitchen and Table Glassware Market in Brazil to 2019 Feb 20‚ 2015 – Navi Mumbai‚ India: Marketreportsonbrazil.com presents a report on “Kitchen and Table Glassware Market in Brazil to 2019 - Market Size‚ Trends‚ and Forecasts.” This industry report offers the most up-to-date market data on the actual market situation‚ trends and future outlook for kitchen and table glassware in Brazil. Summary The research includes historic market data from 2008 to 2014 and forecasts until 2019 which makes the
Premium Future Financial markets Report
This report analyzes the worldwide markets for Calibration Services in US$ Million by the following parameters of calibration: Mechanical Calibration Services‚ Electrical Calibration Services‚ Physical/Dimensional Calibration Services‚ and Thermodynamic Calibration Services. The Global market is also analyzed by the following end-use sectors: Electronic Manufacturing‚ Communication‚ Aerospace & Defence‚ Industrial & Automotive‚ and Others (includes Pharmaceuticals‚ Biotechnology‚ Medical
Premium Metrology Test method Service provider
Global Calibration Services Market 2014-2018 Calibration is an operation undertaken to compare the performance of a measurement instrument against a measurement standard. Calibration indicates the traceability of the instrument and accuracy of the measured data. Industries worldwide are opting for calibration services in their production process. Calibration undertaken at regular intervals helps identifying any faults with an instrument at the earliest‚ reducing downtime and increases production
Premium Measurement Dow Jones Industrial Average Test method
THERMOMETER CALIBRATION USING CONTROLLED TEMPERATURE BATHS TXDOT DESIGNATION: TEX-926-K Test Procedure for THERMOMETER CALIBRATION USING CONTROLLED TEMPERATURE BATHS Texas Department of Transportation TxDOT Designation: Tex-926-K Effective Date: August 1999 1. SCOPE 1.1 Calibrate thermometers by comparison with standard thermometers while immersed in stirred water or oil baths. Alternately‚ calibrate specific points by placing in a reference temperature bath such
Premium Temperature Thermodynamics
Volumetric Analysis of Vitamin C by Titration The objective of this experiment is to use a redox reaction titration to accurately determine the amount of vitamin C in a sample of lemon juice‚ orange juice‚ or grapefruit juice. Chemistry of Vitamin C The chemical name for vitamin C is L-ascorbic acid. Its molecular formula is C6H8O6; its molar mass is 176.12 g/mole. Ascorbic acid is found throughout the plant and animal kingdoms‚ occurring in citrus fruits‚ hip berries (such as rose
Premium