sodium acetate in a batch and in a continuous stirred tank reactor‚ we can evaluate the rate data needed to design a production scale reactor. A stirred tank reactor (STR) may be operated either as a batch reactor or as a steady state flow reactor (CSTR). The key or main feature of this reactor is that mixing is complete so that properties such as temperature and concentration of the reaction mixture are uniform in all parts of the vessel. Material balance of a general chemical reaction described
Premium Chemical reaction Reaction rate Rate equation
| |STUDENT NO. |: |2004624828 | |EXPERIMENT |: |CONTINUOUS STIRRED TANK REACTOR (CSTR) | |DATE PERFORMED |: |17TH JANUARY 2006 | |SEMESTER |: |DISEMBER 2005
Premium Chemical reaction Reaction rate
ABSTRACT In this experiment‚ our objectives are to examine the effect in a tubular flow reactor and to construct a residence time distribution (RDT) for both pulse input and step change. The first experiment is the effect of pulse input in a tubular flow reactor. Before the experiment was done‚ we need to do some general start-up process in order to get a better result and to avoid errors during experiment. After that‚ a constant flow rate was set up at about 700 ml/min. After that‚ both of the
Premium Fluid dynamics
Making an Activity Series of Metals using different Solutions Purpose/ Hypothesis: The purpose of this lab was to clearly identify the reactivity of magnesium‚ zinc and copper. The metals reactivity will be exemplified as it will be tested with different solutions such as zinc sulfate (ZnSO4)‚ copper sulfate (CuSO4)‚ hydrochloric acid (HCL)‚ magnesium sulfate (Mg2SO4)‚ iron (II) sulfate (FeSO4) and tin (II) chloride (SnCl2). This will allow us in creating an activity series to visually see the reactivity
Premium Chemical reaction Metal Sulfuric acid
of Chemical Engineering CHME 426 –Chemical Engineering Laboratory III Title Page (Full Report) Title of the Experiment: Reaction through three CSTR in series Submitted by: Group (4) Section: Female 1. Name: Amina Ali ID: 200550284 2. Name: Duaa Tabarak ID: 200553858 3. Name: Mariam Rustom ID: 200552242 Date of experiment: 31st March‚ 2010 Date of submission: 11th April‚ 2010 Grades: Report presentation………………………………………… /15 Abstract and Objective(s)……………………………………/10 Introduction
Premium Sodium hydroxide Chemical reaction
MEC 325/580 Lab Report CNC Machining Lab Report Date: March 18‚ 2013 Group Leader: Jian Wu Team Members: Group Number: G4 Regment No.: D Insturctor: CONTENTS 1.Objective and introduction. 2.Principles and practice. 3.Design and result. 4.Conclusion and recommendations. Appendices 1. Objective and introduction * Objectives Operate the CNC milling machine using G-codes‚ M-codes in a CNC program. * Equipment: Minitech CNC machine (Series 2) * Machine
Premium Milling machine Numerical control
Microbiology-2460 Lab-003 March 31‚2008 Lab Report-Escherichia coli Abstract The purpose for this lab report was to identify and inform of an unknown bacteria that has been causing a patient to have lower abdominal and pelvic pain. To obtain the identification of this unknown bacterium‚ several biochemical tests needed to be performed in order to prescribe the correct medication to treat and cure the symptoms. Introduction In a lab today‚ I am to identify an unknown bacterium that is
Premium Escherichia coli Bacteria
hydrocarbons‚ PCBs‚ pesticides‚ herbicides‚ and other organics. Page 1 of 3: Analytical Result A. Header Information 1. After "Project No:"‚ enter the client’s project number (from cover page 1). This number is required on every page of the report. 2. After "METHOD"‚ enter the analytical method used. (e.g.‚ EPA 8260‚ or EPA method 8021). 3. After "REPORTING UNIT"‚ enter the appropriate reporting unit. The units ug/L for water samples and ug/Kg for soil samples are recommended for volatile
Premium Benzene Volatile organic compound Analytical chemistry
Theory In the experiment‚ in an LRC circuit‚ a resistor(R)‚ an inductor (L) and a capacitor (C) are required to connect in series. Just like the figure shows. In the experiment‚ we want to calculate the resonance frequency. We know the current will be maximum when the circuit is driven at its resonance frequency. In addition‚ the amplitude I0 of the AC current in a series LRC circuit depends on the amplitude V0 of the applied voltage and the impedance Z‚ which is a measure of the overall opposition
Premium Alternating current Inductor Electrical resistance
CHM1032L pre/post lab instructions Preparation is a key to success in this lab. For this reason‚ you are required to thoroughly read through the experiment information presented in the lab manual‚ and complete a pre-lab for each experiment you do. The prelab must be completed prior to the day of the experiment. Each Friday I will ask to see your completed prelab before I allow you to enter the lab. If you have not finished the pre-lab‚ I will not allow you to enter the lab and you will receive
Premium Laboratory Experiment Stanford prison experiment