Sowman | Practical 7: Determination of Hardness in Water | | | | | 10/3/2012 | | Aim: To determine the different types of hardness and alkalinity found in the water by titration methods. This is used to calculate the concentrations of calcium and magnesium found in the water. Principles: The hardness of water is determined to provide a measure of the quality of water for household and industrial use. Hard water is not a health hazard. Drinking hard water contributes a small
Premium Hard water Bicarbonate Calcium
Complexometric Determination of Water Hardness Lab Report Introduction: In this lab the use of disodium salt of EDTA is used to determine the concentration of M^2+ metal ion impurities in hard water by chelometric titration. The indicator Eriochrome Black T will help detect when you EDTA has completely chelated the metal impurities. Chemical Principle: A complex ion consists of a metal ion with Lewis bases attached to it. These Bases form strong covalent bonds with the central complex
Premium Calcium Water Hard water
Lab 7: Determination of Water Hardness Using a Titrator Name: Kyndal Petrie Lab Partners: None Date of Experiment: July 19‚ 2013 Location: My house Course Number: Che112 Abstract: This experiment was to determine the hardness of the local water supply. I determined that from the 1mg of EDTA used to turn the mixture blue‚ that the water from my tap is moderately soft. Experiment and Observation: In this experiment I developed a familiarity with the concept
Premium Water Hard water Calcium
Water “hardness” was analyzed in this experiment‚ through the determination of CaCO3 concentration. This was achieved by the titration of an unknown solution using a standardized 0.1M EDTA‚ and addition of Eriochrome Black T to the unknown‚ to indicate the endpoint of the titration. The average concentration of CaCO3 obtained was 1034 ppm‚ with a standard deviation of 2.4495. The results indicate that the unknown solution can be considered as hard water. Introduction The hardness of water
Premium Titration Calcium Calcium carbonate
The objective of this lab is to determine the hardness of water‚ using the data collected from each titration performed with the unknown sample. Since the hardness of water arises from the presence of metal ions‚ we can use disodium salt of EDTA and the indicator Eriochrome Black T to determine the concentration of M 2+ ( Mg 2+ or Ca 2+) metal ion impurities. Chemical principle or theory involved in this lab: To determine waters hardness we will use a technique called a chelometric titration
Premium Calcium Water Hard water
Complexometric Determination of Water Hardness Abstract: Create a standardized EDTA solution for use as a titration solution to determine the hardness of water from a single random sample. Introduction: Using a calibrated EDTA solution to determine water hardness from a random sample. Essentially the Na2EDTA solution reacts one to one with the mineral content of a sample of tap water and by use of a standardized solution a ppm estimation can be obtained for the hardness of water. Current knowledge
Premium Calcium Hard water Calcium carbonate
CHM152LL LAB MANUAL COMPLEXOMETRIC DETERMINATION OF WATER HARDNESS Complexometric Determination of Water Hardness Introduction Complex ions When a neutral molecule or anion (a Lewis base) donates electron pairs and attaches itself to a metal ion center (a Lewis acid)‚ the resulting cluster‚ or complex‚ of atoms becomes a single complex ion. When such complexes form‚ the electron donating groups (called ligands) form coordinate covalent bonds through empty orbitals on the metal ion. An example
Premium Calcium Water Calcium carbonate
Complexometric Determination of Water Hardness. Abstract: Using complexometric method of calculating water hardness‚ an EDTA solution was made and calculated to be around .00209M. This EDTA solution was then used to titrate a water sample with unknown hardness. The sample used was sample #18. The hardness of the sample was calculated to be 180505 ppm. This is within normal levels for the Mesa area. Introduction: This experiment focuses on titration with EDTA. Titration
Premium Titration Water Calcium
Complexometric Determination of Water Hardness Kayla Partridge Britni Gonzales 09/15/2014 Abstract Determining the water hardness of unknown sample #55 was determined by complexometric titration. With the use of disodium salt EDTA as the solution to chelate the metal impurities and the Eriochrome Black T indicator as the solution used to help visualize when the impurities were completely chelated‚ along with a few other solutions to help the reaction. Unknown water sample #55 experimental
Premium Calcium Water Hard water
Complexometric Determination of Water Hardness 9/12/2013 Abstract: Two sets of acid-base neutralization titrations were conducted for experimental analysis. The first set of titrations was to standardize a solution manufactured in the lab. An approximate solution of Na2EDTA of 0.004 M was titrated against a known solution of 1.000 g CaCO3/L to deter mine to exact molarity of the Na2EDTA. Ca2+ + Na2EDTA → CaEDTA + 2Na+ The second set of titrations was to use the now standardized Na2EDTA
Premium Titration Acid Water