EC2259 Electrical Engineering And Control System Lab Manual LAB MANUAL VEL TECH MULTI TECH ( ISO 9001: 2000 Certified Institution & NBA Accredited ) (Owned by VEL Sree R.Rangarajan Dr. Sagunthala Rangarajan Educational Academy) Approved by AICTE‚ New Delhi & Affiliated to Anna University No 42‚ Alamathi Road‚ Near Avadi Chennai – 600 062 DEPARTMENT OE ELECTRONICS AND COMMUNICATION ENGINEERING EC 2259 - ELECTRICAL ENGINEERING AND CONTROL SYSTEM LAB II YEAR IV SEM ECE Prepared By
Premium Transformer Electrical generator Electric motor
Power System Fault Analysis 2.0 Introduction The fault analysis of a power system is required in order to provide information for the selection of switchgear‚ setting of relays and stability of system operation. A power system is not static but changes during operation (switching on or off of generators and transmission lines) and during planning (addition of generators and transmission lines). Thus fault studies need to be routinely performed by utility engineers (such as in the TNB). Faults
Premium Circuit breaker Electrical engineering Transformer
Ohm’s of the resistor‚ therefore confirming Ohm’s Law. An ammeter is connected in series because its purpose is to measure the current in the circuit‚ and since it is a low impedance device‚ connecting it in series would cause a short circuit‚ damaging the ammeter. Whereas the voltmeters purpose is to measure the electrical potential difference between two points in the circuit. The potential difference
Premium Ohm's law Voltage Electric current
. M ODELING OF STATCOM AND UPFC FOR POWER SYSTEM STEADY STATE OPERATION AND CONTROL Vaibhav Dahiya Author Registration No: UE111041 * Department of EEE‚ UIET‚ PANJAB UNIVERSITY‚ CHD ‚ INDIA ‚ vaibhavdahiya89@gmail.com Keywords: Power flow‚ Newton Raphson‚ FACTS controller‚ STATCOM‚ UPFC Abstract In recent years‚ energy‚ environment‚ deregulation of power utilities have delayed the construction
Premium Electric power transmission Electrical engineering Electricity distribution
should be noted that‚ increasing the loop gain of control system can enhance the inverter output impedance and reduce the current distortion caused by the grid voltage. However‚ this approach is compromised by the system stability requirement. Another way which has received special attention recently‚ is using feedforward of the grid voltage in control system. This method can boost the inverter output impedance very well but‚ introduces negative phase angle to the control system in weak grids which might
Premium Alternating current Electrical engineering Electric motor
COURSE STRUCTURE & SYLLABUS OF MASTER OF TECHNOLOGY (M.TECH) In Electrical Engineering Course Structure First Year First Semester Paper Code Subject MFE1 Machine Drives MFE2 Power Electronic Converter MFE3 Control System MFE4 EHV Transmission Syllabus MFE1 : MACHINE DRIVES –I 1. CHARACTERISTICS OF THE ELECTRIC MOTORS Introduction‚ Characteristics Of Dc Motors‚ Characteristic Of Three-Phase Induction Motor ‚ Variation Of Applied Voltage‚ Pole Change Motors
Premium Control theory Electrical engineering Electric motor
Outline the development of a new area of research in your field.Account for its importance and evaluate the extent of its usefulness. Outline Introduction ! People are facing with energy shortage which will affect economic growth.Nuclear electrical power generation is a new type of power generation‚it contains advantages and disadvantages‚both of them are discussed and put forward whether nuclear power generation will completely replace the tradition way of power generation. ! ! Main
Free Nuclear power Nuclear fission Coal
LIGHTING RESEARCH PROGRAM Project 3.2 Energy Efficient Load-Shedding Lighting Technology Consultant Report FINAL REPORT Prepared For: California Energy Commission Public Interest Energy Research Program Arnold Schwarzenegger‚ Governor October 2005 CEC-500-2005-141-A6 Energy-Efficient Load-Shedding Lighting Technology Architectural Energy Corporation/LRC CALIFORNIA ENERGY COMMISSION Prepared By: Lighting Research Center. Andy Bierman‚ Project Lead Managed By:
Premium Fluorescent lamp Peak oil
Laboratory No 4 Electrical Systems 100 AC CIRCUITS INTRODUCTION The purpose of this laboratory test was to make comparisons between theoretical and practical results and to develop a greater understanding of factors affecting the operation of complex AC networks. SUMMARY OF RESULTS The error in the results ranges from 0.02% to 22.63% and the phase angle errors ranged from 0.02° to 17.27°. This suggests that part of our results were very accurate (series parallel RC network) and the rest
Premium RC circuit Alternating current Inductor
LEVEL 2 UNITChapter 204 1 Principles of electrical science 11 Level 2 Electrical Installations (Buildings and Structures) This chapter covers: Chapter 1 the principles of electricity the principles of basic electrical circuits the principles of magnetism and electromagnetism the operating principles of a range of electrical equipment the principles of basic mechanics the principles of a.c. theory electrical quantities in Star Delta configurations. LO1 Matter – something that has weight
Premium Resistor Electric current Series and parallel circuits