MINI PROJECT ELECTRICAL INSTALLATION ELECTRICAL SERVICES FOR CONDOMINIUM TABLE OF CONTENT 1.0 Layout Plan and Design 1.1 1.2 2.0 3.0 Location Layout Plan Electrical Power Distribution Design Details of Design 3.1 3.2 3.3 Load Estimation & Lux Determination Propose & Design Electrical and Power Services Schematic Diagram for DB‚ SSB‚ &MSB 4.0 Maintenance Strategy 4.1 4.2 Transformer Switch GearandBackup Power System 5.0 6.0 7.0 Conclusion Reference Appendix 1.0 Layout Plan
Premium Circuit breaker Electricity distribution Electrical engineering
1. INTRODUCTION Electrical substation for distribution system is the main supply to convert the high voltage (HV) to low voltage (LV) and the place where load are distributed to the consumers. In Malaysia‚ Tenaga Nasional Berhad Distribution (TNBD) used the 33/0.433kV‚ 22/0.433kV‚ 11/0.433kV and 6.6/0.433kV voltage system for the electrical system to supply for domestic consumer and industrial consumer such as factory which will supplied directly from Transmission Main Intakes (PMU)‚ Main Distribution
Premium Transformer Electromagnetism Circuit breaker
conveniently designed conductive disks allow the electrical load of the generator to be fed either with alternating current or direct current. the loop terminals is sinusoidal with zero mean value (Fig. 2). Its frequency is equal to the number of revolutions per second executed by the loop. Each terminal of the loop is connected to a metallic ring. The contacts with rings are made by means of fixed brushes. If the brushes are connected to an electrical load‚ an alternating current will be established
Premium Electrical generator Electromagnetism Alternating current
L&T SWITCHGEAR SAFE & SURE ELECTRICAL SAFETY E S P SERVICE MANUAL GENERAL Electricity is good servant but bad master. It can prove to be very dangerous if circuits are not properly protected. The major fault that appears in electrical network or equipment is termed as short circuit. In short circuit‚ the supply phase and neutral or earth is short circuited accidentally due to foreign metallic substance coming in contact with phase & neutral or earth or due to overload thereby damaging
Premium Electric charge Electricity Electrical engineering
ENGR. JAY S. VILLAN‚ MEP-EE Introduction A multitester or multimeter is a device which can be used to gather data about electrical circuits. A basic multitester can measure resistance‚ voltage‚ and continuity; while more advanced versions may be able to provide additional data. This tool can be very useful to have around the house‚ and anyone who plans on doing electrical repairs should most definitely use a multitester for safety reasons. Multitesters can be used with the current off or on in
Premium Electrical resistance Multimeter
Gs=Y(s)u(s) L d2Ytdt2+ L dYtdt+ L Yt=2 L dutdt+L ut s2Ys+sYs+Ys=2s us+u(s) s2+s+1Ys=2s+1 u(s) Gs=Y(s)u(s)=2s+1s2+s+1 Electrical network transfer function component | Voltage-current | Current-voltage | capacitor | vt=1c0titdt | it=c dV(t)dt | resistor | vt=Ri(t) | it=1Rv(t) | inductor | vt=Ldi(t)dt | it=1Lotvtdt | component | Voltage-charge | Impedance | capacitor | vt=1cq(t) | 1c | resistor | vt=Rdq(t)dt | R | inductor | vt=Ld2q(t)dt | LS | * Find
Premium Control theory Electrical impedance Derivative
Electrical installation handbook Volume 2 3rd edition Electrical devices 1SDC010001D0203 ABB SACE Electrical installation handbook Volume 2 Electrical devices 3nd edition June 2005 Index Introduction ............................................................................................................... 2 1 Standards 1.1 General aspects ............................................................................................. 3 1.2 IEC Standards for electrical
Premium Electricity Electrical engineering Alternating current
Title AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules) Licensee Licensed to LUU MINH LUAN on 25 Feb 2002 Conditions of use This is a licensed electronic copy of a document where copyright is owned or managed by Standards Australia International. Your licence is a single user licence and the document may not be stored‚ transferred or otherwise distributed on a network. You may also make one paper copy of this document if required. Web Check-up
Premium Electricity distribution Electrical wiring Electricity
DSE BASED ZONE PROTECTION: The dynamic state estimation based protection (also known as setting-less protection) has been inspired from the differential protection function and can be considered as an extension and generalization as illustrated in Figure 1. In current differential protection the electric currents at all terminals of a protection zone are measured and their weighted sum must be equal to zero (generalized Kirchhoff’s current law). Thus the current differential protection function consists
Premium Energy Alternating current Capacitor
BECHTEL CORPORATION ELECTRICAL ENGINEERING HANDBOOK COMPARISON OF IEC- ANSI/NEMA Prepared by : M McLaughlin (LOEU) Special Recognition to: B. Hibbett (LOEU) M. Donati (HOEU) 0 A 13-Jan-00 12-NOV-99 REV. DATE LORO ISSUED FOR CORPORATE USE ISSUED FOR COMMENT REASON FOR REVISION MM MM BY BP BP CHECK BECHTEL CORP KGH KGH APPR REV 000 ELECTRICAL ENGINEERING HANDBOOK 3DG-E15-00002 COMPARISON OF IEC - ANSI/NEMA Page 1 of 44 E BECHTEL CORPORATION E&C CENTRAL FUNCTIONS
Premium Electrical wiring Circuit breaker Cable