ISE: The Determination of Chloride Unknown: #34 I. Purpose: In experiment V‚ “ISE: The Determination of Chloride”‚ the concentration of an Unknown Chloride solution‚ and the Wt% of NaCl in a sample of celery salt‚ were both determined. To determine the concentration of an Unknown Chloride solution‚ a Calibration plot is first prepared. The Calibration plot is made by first measuring a series of known concentrations of Cl- (with the same activity of the unknown solution) and obtaining
Premium Chemistry Chlorine Water
ISE Determination of Fluoride Content in Various Substances CHM 222 – A 4 / 20 / 2007 Introduction: The ion selective electrode used was made up of a silver / silver chloride reference electrode and a glass electrode. The pH of the electrochemical cell is determined by monitoring the electrical potential difference between the half-cells. The glass electrode is an ion selective electrode (ISE)‚ which only responds to the hydronium ion concentration / activity in a solution under a
Premium Electrochemistry Solution PH
Purpose: The purpose of this was to determine the concentration of sodium carbonate in an unknown sample by titration. The solution of hydrochloric acid was prepared and standardized using Na2CO3. Observations: Week 1: Standardizing hydrochloric acid using sodium carbonate with bromocresol green indicator Table 1: Titration of sodium carbonate using hydrochloric acid Trial | Mass of Na2CO3 (g) | Burette Reading (mL) | Final Volume of HCl (mL) | | | Initial | Final | | 1
Premium Titration Hydrochloric acid PH
Abstract The chloride present in an unknown soluble sample was precipitated into silver chloride through precipitation gravimetry. The colloidal silver chloride originally formed was converted to a crystalline solid by controlling certain parameters of the experiment such as temperature‚ pH of the solution‚ and concentration of AgNO3. Once the solid was large enough‚ it could be washed‚ filtered‚ and weighed. The percentage of chloride present was found to be 24.73695223 (±0.00000006) %.
Free Solubility Silver Ion
are unavailable. The purpose of this experiment‚ performed by Ryan Nelson‚ Peter Glascor‚ Eric Flowr was to determine the identity of the unknown polymer by comparing its properties to properties of other known polymers. Most likely‚ the part is one of the five following polymers: polyethylene‚ polypropylene‚ polystyrene‚ polycarbonate‚ poly(vinyl chloride). These are all extremely common‚ and have widespread applications in industry. Each of these polymers exhibits properties which allow it
Premium Plastic Polymer Melting point
Submitted: October 00‚ 2014 Experiment No. 7 Unknown: 2 Compound: Table 6.1Physical Examination State Liquid Odor Smells like adhesive paste Color Pink-orange Flammability Flammable Table 6.2Physical Constant: Melting Point Parameter Experimental Theoretical (From Literature) Melting Point (oC) Trial 1 Trial 2 Average 88 88 86 86 Table 6.3Solubility Test Sample Solubility Solubility Class Water Ether 5% NaOH5% Na2CO3 5% HClConc. H2SO4 Unknown Sample + + + + + + Basic Compound Table 6
Premium Functional group Carboxylic acid Acetic acid
Purpose: I will identify an unknown liquid by obtaining an average density & boiling point for my liquid and comparing them with the known densities & boiling points of liquids in the CRC handbook of Chemistry & Physics. I will perform these experiments using three different measuring tools (graduated cylinder‚ burette & pipette) to evaluate the precision of each one. Results: Density 1‚ 2 & 3 calculated by using graduated cylinder to obtain volume. Density 4‚ 5 & 6 calculated by using volumetric
Premium Water Temperature Density
Chemistry Lab Report Purpose The purpose of this lab is to determine the identity of an unknown liquid by measuring its density and its boiling point and try to match it with those solutions given in Table 2 of experiment 2. Procedure Part A In Part A‚ The main purpose was to find the determination of the density of the unknown (j41) and by doing that we had to determine volumes of the unknown liquid (j41) using three different volumetric devices which are graduated cylinder‚ pipette
Premium Volume Water Density
-1Determination of an Unknown Liquid (2-butanol) Through Fundamental Analysis Lee Billips Department of Chemistry‚ Shippensburg University‚ 1871 Old Main Drive. Shippensburg‚ PA‚ 17257. Abstract: The identification and characterization of unknowns are an important part of organic chemistry. It is fundamental to know experimental methods to deductively identify compounds (1) . The determination of unknown #6 (2-butanol) was identified by a series of test; first taking the boiling point (94-96
Premium Chemistry Atom Temperature
Determination of An Unknown Amino Acid From Titration Abstract Experiment 11 used a titration curve to determine the identity of an unknown amino acid. The initial pH of the solution was 1.96‚ and the pKa’s found experimentally were 2.0‚ 4.0‚ and 9.85. The accepted pKa values were found to be 2.10‚ 4.07‚ and 9.47. The molecular weight was calculated to be 176.3 while the accepted value was found to be 183.5. The identity of the unknown amino acid was established to be glutamic acid‚
Premium Acid Acid dissociation constant PH