10/24/2013 LAB TITLE: Single Replacement Reaction of Solid Copper with Silver Nitrate PURPOSE The purpose of this lab is to: • Observe a single replacement reaction‚ and • Calculate the mole ratio of silver (Ag) to copper (Cu) in the reaction MATERIALS • Copper wire (30 cm) • Large test tube • 250 ml beaker • Silver nitrate (AgNO3) powder • Dilute AgNO3 solution • Distilled water • Electronic balance • Glass stir rod • Watch glass PRE-LAB DISCUSSION A single
Premium Silver Copper Force
[ print page ] 3.01 Cell Cycle Lab Report Safety Notes: Always handle microscopes and glass slides carefully. Wash your hands after handling the prepared specimens. Materials: Compound light microscope Glass microscope slide with prepared onion root tip specimen Purpose: understand and identify the stages of the cell cycle and mitosis. apply an analytical technique to estimate the relative length of each stage of the cell cycle. Hypothesis: What do you predict you will find
Premium Cell cycle Mitosis Microscope
LAB Report #3 Introduction: In this lab we have focus on Isolation of bacteria from environment. Microorganisms are found throughout the environment: in the air and water; on the surface of any object such as clothes‚ walls‚ furniture; in soil and dust; and on and in our own bodies (skin and mucous membranes). In order to demonstrate the ubiquity and diversity of microbes in the environment‚ samples from immediate areas of the environment and/or from your body will be obtained and cultured
Free Agar plate Petri dish Growth medium
Groelke________________________________________________________________________ Date______November 13‚ 2012_______________________________________________________________ Course and Lab Section Number___PHY 1150-202________________________________________________ Collaborators_Briana‚ Travatello‚ Grayson North‚ Roy Huffman ______________________________ |Laboratory Report Scoring Rubric | |
Premium Energy Kinetic energy Mass
Lab Report: Halogen Reactions Purpose: This experiment will allow for exploration into some of the properties of Group 17 elements (halogens) and their compounds. More specifically‚ the solubility properties of these halogens will be used to predict their reactions. The relative electronegativities of the halogens will be determined. Halides‚such as Cl-‚ Br-‚ and I- will be used to make these determinations. Because this lab is qualitative rather than quantitative‚ there are no calculation
Premium Chlorine Electronegativity
Nervous System lab was designed to measure reaction times by using a variety of tests that affect the heart rate. These tests were the startle‚ stroop‚ Valsalva maneuver‚ diving reflex‚ and a test of our choice. The test our group chose to measure the heart rate in response to doing a trust fall to anticipate the stress right before the fall. To begin this lab we chose a participant‚ and then hooked their finger up to the pulse transducer sensor. Using the chart 5 program on the lab computer the participant’s
Premium Parasympathetic nervous system Autonomic nervous system Peripheral nervous system
hydrocarbons‚ PCBs‚ pesticides‚ herbicides‚ and other organics. Page 1 of 3: Analytical Result A. Header Information 1. After "Project No:"‚ enter the client’s project number (from cover page 1). This number is required on every page of the report. 2. After "METHOD"‚ enter the analytical method used. (e.g.‚ EPA 8260‚ or EPA method 8021). 3. After "REPORTING UNIT"‚ enter the appropriate reporting unit. The units ug/L for water samples and ug/Kg for soil samples are recommended for volatile
Premium Benzene Volatile organic compound Analytical chemistry
Kiley O’Toole Lab Report 3 Purpose The purpose of this lab was to uncover the number of layers of zinc atoms around a piece of galvanized iron. This was done by pouring the hydrochloric acid onto the galvanized iron‚ thus removing the zinc from the piece of metal. Laboratory Procedure 1. Measured and recorded the mass of a piece of galvanized iron using a centigram balance and a ruler 2. Measured and recorded the length and width of the galvanized iron using the ruler 3. Put the
Premium Hydrogen Zinc Length
Lab Report 7: Analysis of Cereal Introduction: The objective of this lab was to consult for the FDA regarding a recently surfaced scandal involving false reporting of iron content in cereal as well as iron tablets. The makers of the cereal and the iron tablets‚ respectively‚ were allegedly reporting higher amounts of iron in their products than actually existed‚ as a way to save money but continue to provide products with “adequate” amounts of iron. The FDA needed consulting in order to analyze
Premium Iron
Adwoa Fosuah Bio Psych Lab Report 4 Cold Pressor Task Aim The cold pressor test is done by having the subject submerge their hands in a bucket of cold water to determine cardiovascular changes such as blood pressure and heart rate. For this experiment we wanted to know how long participant can keep their feet in the bucket of ice water before they experience any pain while looking at neutral and positive pictures and also rate the intensity of their pain. For this reason we hypothesized that
Premium Standard deviation Arithmetic mean Time