Percent Yield Aim To determine the limiting reagent between the reaction of lead (II) nitrate and potassium iodide. To determine the percent yield of lead (II) iodide. Date Started: 13/4/12. Finished: 19/4/12. Data collection and processing Measurements: * Amount of distilled water: 75.0ml ± 0.5ml. * Mass of watch glass: 31.65g ± 0.01g. * Mass of watch glass + potassium iodide: 32.45g ± 0.01g. * Mass of potassium iodide: 0.8g ± 0.02g. * Mass of watch glass + lead (II) nitrate:
Premium Stoichiometry Yield Molecule
Experiment Title: Torsion Vibration. Introduction : Torsion is the twisting of a metallic rod shaped object‚ when a torque is applied on two sides’ perpendicular to the radius of a uniform cross-sectional bar. Objective : Determining the natural frequency of a system undergoing tortional vibration. Theory : Using Newton’s second law of tortional system. ( [pic] …………………. ( Equation 1 ) where Io = mass moment of inertia of the disk Hence‚ [pic] ……..……
Premium Torque Inertia Fundamental physics concepts
Laboratory Report The Plasma Membrane I. Introduction The Plasma membrane is the edge of life‚ the boundary that separates the cell from its surroundings. It controls the traffic of materials in and out of the cell. (Reece‚ 2011). It is incredibly thin that is very vital in maintaining the integrity of the cell. Not only does the plasma membrane bind the other organelles‚ it also forms a dynamic structure which gives them their remarkable activity and selectivity. (Hickman‚ 2008). Diffusion
Premium Osmosis Cell membrane Red blood cell
of Chemical Engineering CHME 426 –Chemical Engineering Laboratory III Title Page (Full Report) Title of the Experiment: Reaction through three CSTR in series Submitted by: Group (4) Section: Female 1. Name: Amina Ali ID: 200550284 2. Name: Duaa Tabarak ID: 200553858 3. Name: Mariam Rustom ID: 200552242 Date of experiment: 31st March‚ 2010 Date of submission: 11th April‚ 2010 Grades: Report presentation………………………………………… /15 Abstract and Objective(s)……………………………………/10 Introduction
Premium Sodium hydroxide Chemical reaction
LSM1102 Lab Report Introduction Transformation is a process which involves plasmid DNA being bound to the cell surface and the subsequent uptake of DNA by the cell (Panja et al.‚ 2008). For artificial transformation of E. coli cells with plasmids‚ plasmid DNA has to be extracted from bacterial cells using the High-Speed Plasmid Mini Kit‚ which is then mixed with competent E. coli cells followed by heat shock and the streaking of transformed cells on two different types of agar plate (LB and LB+ampicillin)
Premium Plasmid Transformation Escherichia coli
PEES 4200W- Physiology of Exercise Lab #2: Metabolism and Energy Expenditure 1. The Respiratory exchange ratio is the ratio of the volume of carbon dioxide produced and oxygen consumed. The ratio indicates the energy that the subject is expending for indirect calorimetry‚ how efficient the subject ’s body is at utilizing the oxygen inhaled‚ as well as the main substrate being used for energy during varying intensities of exercise. During rest the volume of carbon dioxide was 0.73L/min‚ the volume
Premium Oxygen Carbon dioxide Ratio
Part 2: Safe work with large inductances 1. One of the main hazards of using inductances is electrical energy stored in the magnetic field. If a circuit containing an inductance is interrupted then the stored energy can release through air (forming an arc). This can destroy a switch contact‚ burn fingers‚ create other damage. In the circuit of Figure 1‚ show how to mitigate the risk (pay attention to polarity!). We give the elements in this circuit some simple values for the purpose of
Premium Voltage Electrical resistance Electricity
Laboratory Techniques and Measurements Lab 1 The purpose of this lab was for the student to get involved with his or hers new lab kit as well as being able to know‚ identify and use each other tools provided in the kit. Another key learning aspect of this lab is to teach the student how to measure properly the many units in the SI system. I will be using laboratory dilutions‚ measurements‚ and weights to then calculate using algebraic formula. Throughout lab one we were introduced to
Premium Units of measurement Length
Name : Siti Zulaikha Binti Dahalan Matric. No : FIS 1307 3296 Name of Partner : Title of Experiment : Experiment 2‚ Uncertainty and Error Date Of Experiment : 1st October 2013 Course Name and Code : Physics Lab 1 (FP1021) Instructor’s name : Dr. Azah Nik Jaafar Objective 1. To measure Human Reaction Time 2. To find uncertainty and error of a measurement Apparatus 1. Ruler Theory Human Reaction Time is a measure of how quickly human can respond to a particular stimulus. This
Premium Measurement
chemicals before use. Abide by specific warnings and directions. 3. Collect all materials needed for a procedure before proceeding. 4. Perform reactions under the hood when directed. Chemicals may be weighed and prepared at balance or lab tables‚ but tests should be carried out under the hood. 5.Acids and caustic chemicals are stored in the hood. Please do not take these chemicals from the hood. Procedure: PART 1: Metathetical reactions Precipitation reactions A1. Add a
Premium Chlorine Chemical reaction Sodium