EXPERIMENT (4) FLOW MEASUREMENT By: Eng. Motasem M. Abushaban. Eng. Fedaa M. Fayyad. PURPOSE: To study some of the famous instruments used in flow measurements. The measurement of water flow rate is an important topic in the study of fluid dynamics. There are many instruments used in flow measurements such as : o Venturi o Orifice plate o Variable area meter DESCRIPTION OF APPARATUS Water Flow Measuring Apparatus is designed as a free-standing apparatus for use on the
Premium Fluid dynamics
(ripping out of pipes and meters‚ spilling sewage and trash outside municipal buildings).This essay will argue for and against the prepaid water meter system with regard to its advantages and disadvantages as viewed by the people verses the government. What is a prepaid water meter? www.apf.org.za states that there are several types of prepaid water meters but the idea behind them is the same. If you cannot pay upfront‚ you are unable to access water. Water from prepaid water meters typically cost more
Premium Water supply network Water supply Drinking water
K.W.H. METERS Prepared by :- Devesh Kumar‚ 303956 (3rd year) CONTENTS * Certificate * Acknowledgement * Introduction of training * Company Profile * Products of BENTEX * Quality Policy and processes of BENTEX * Electricity meter * Direct current (DC) * Alternating current (AC) * Unit of measurement * Others Unit of measurement * Types of meters 1. Electromechanical meters 2. Electronic
Premium Electricity distribution Electricity generation
Lecture No. 5 CLASSIFICATION OF FLUID FLOW AND THE CONTINUITY EQUATION 5.1 Classification of Fluid Flow Uniform flow If the velocity of the fluid is the same in magnitude and direction at every point in the fluid the flow is said to be uniform. Non-uniform flow A non-uniform flow is one where the velocities at different points at a given instant are not the same. Every fluid that flows near a solid boundary will be non-uniform because the fluid at the boundary takes the velocity of the
Premium Fluid dynamics
MASS 10/8/14 The Path to Salvation What is Mass the Latin word “missa”. Mass said in Latin‚ ends in “Ite missa est” meaning “Go‚ it (the church) is sent”. Through the Mass‚ we come to know God-Jesus invites us to Himself‚ then we are dismissed to be Christ for the world. For Catholics‚ participating and celebrating Mass is a pathway to salvation because it was revealed specifically by Jesus at the Last Supper. What is Liturgy? The Mass is referred to as the “Divine Liturgy”‚ meaning God’s public
Premium Mass Eucharist Jesus
ULTRA-SONIC DISTANCE METER. Introduction to Ultrasonic Distance Meter The project Ultrasonic Distance Meter is a very interesting and useful project for many industrial applications. In this project we have used the ultrasonic waves to measure the distance in between two points. The basic principal is based on the speed of ultrasonic waves in open air. We have used a microcontroller AT89S51 to transmit and receive ultrasonic waves through 40 KHz ultrasonic receiver and transmitters. By measuring
Premium Rate of return Management Mind
performed was Experiment IV: Fluid Flow Meters and Tray Hydraullics. The group was composed of Alex Long‚ Khanh Ho‚ Tricia Heitmann and myself. The first day of experimentation was April 16‚ 2013. On this day‚ Alex and I ran the sieve tray apparatus to study the vapor and liquid tray hydraulics parameters for sieve type crossflow distillation trays. Tricia and Khanh ran the fluid flow apparatus to determine the operating characteristics of the Venturi and orifice meters. Day 2 of the experiment was
Premium Fluid dynamics Volumetric flow rate
Single phase induction type energy meter is also popularly known as watt-hour meter. This name is given to it. This article is only focused about its constructional features and its working. Induction type energy meter essentially consists of following components: 1. Driving system 2. Moving system 3. Braking system and 4. Registering system Driving system It consists of two electromagnets‚ called “shunt” magnet and “series” magnet‚ of laminated construction. A coil having large number
Premium Magnetic field
M ~ E S S O R S AND MICROS~TEMS ELSEVIER Microprocessors and Microsystems 20 (1996) 297-301 Technical application Microcontroller based LCR meter M.A. Atmanand‚ V. Jagadeesh Kumar Department of Electrical Engineering‚ Indian Institute of Technology‚ Madras 600 036‚ India Received 19 March 1995; revised 10 May 1996 Abstract A microcontroller based scheme for LCR measurement is described. The unknown element (an inductor or a capacitor or a resistor) is measured employing a non conventional
Premium Voltage Capacitor Electrical impedance
ABSTRACT The flow measuring apparatus is designed to study which the most preferable flow meter from different typical methods of measuring the discharge of an incompressible fluid. This can be identify by measuring the flow rate and the head loss with later to be compared to the different flow meter which is venture meter‚ orifice meter and rotameter. INTRODUCTION The objectives of this experiment are to demonstrate the characteristics of some various commonly used methods of measuring fluid flow rates
Premium Fluid dynamics