Aim: To find the mass in grams (m) of a paperclip. Apparatus: Procedure: 1. Using a piece of string‚ the external circumference(C) of the small test tube was found and was then used to find A ‚ the cross sectional area of the small test tube A=C24π . 2. The beaker was placed under the test tube after it was clamped on the retort stand to collect excess water. The large test tube was filled with water. After which‚ the small test tube which had a fitted scale was placed inside to float
Premium
Spokane‚ Washington. Viney and Fenton (1998) defined the term electrophoresis as‚ “the migration of charged particles through a static medium under the action of an applied electric field (p. 576). Just from this definition‚ it is clear that numerous physics concepts can be used to help explain why electrophoresis works. First‚ I will discuss charge and electric fields and how these principles are utilized in gel electrophoresis. This will be followed by a
Premium Electric charge Electromagnetism Electron
LaGarrian Harris|Date: 2/10/2013| Exp 2: Laboratory Techniques & Measurements|Lab Section: 1411| Data Tables: Length Measurements Object Measured|Length in cm|Length in mm|Length in m| Key|5.2|52|0.05| CD|12.0|120|0.12| Spoon|15.0|150|0.15| Warm Temperature Measurements Hot tap water temperature __44.0 ˚?C 111.2˚?F 317.15_K Boiling water temperature at 5 min __100_˚?C _212 ˚?F 373.15_K Cold Temperature Measurements Cold tap water temperature _19.0_˚?C _66.2_˚?F 292.15
Premium Density Temperature Volume
Basic Lab Measurements and Equipment Purpose This lab experiment displays the accuracy of scientific measuring equipment. This experiment also helps to familiarize the students with these instruments. Procedure: Measure Volumes and Masses 1. Obtain a 400mL beaker and record its mass in grams. 2. Add 40mL of water to the beaker and record the volume. 3. Records the beaker’s mass now with the added water 4. Transfer the water from the beaker to a 50mL graduated cylinder and record the measurement
Premium Test method Chemistry Volume
Measuring Time Date Due: 2013.09.23____ Name: Lily Li____ Class: A__ Teacher: ___Mrs Slater___ Purpose: To determine the period and the frequency of a ticker timer. Materials/Apparatus: One ticker timer One carbon paper disc One 1.5+ meter tape One test tape One stop-watch Theory: The recording timer is a device that helps you study motion‚ it is a simple electric device plugged
Premium Time Frequency Error
Science in the Big City: Exploring Career Opportunities in the Natural and Physical Sciences New York City May 13-18‚ 2014 Students in the Natural Sciences at the University of Houston-Downtown are generally accomplished and motivated students with strong interests in science. However‚ students typically have a very limited perception of the science careers available to them outside of medicine. To educate students as to the array of potential careers available in the sciences (not medicine)
Premium New York City Natural science Nature
DCP CE lab report for thermal physics Jeff Raw data collection: temperature (K)±1K | length (cm)±0.05cm | diameter(cm) ±0.05cm | volume(cm^3) | uncertainty for volume | 342 | 7.3 | 0.28 | 0.449271 | 0.163531 | 338 | 7.0 | 0.28 | 0.430808 | 0.156937 | 336 | 6.7 | 0.28 | 0.412345 | 0.150343 | 334 | 6.3 | 0.28 | 0.387727 | 0.141551 | 331 | 6.1 | 0.28 | 0.375418 | 0.137155 | 329 | 5.9 | 0.28 | 0.36311 | 0.132759 | 326 | 5.5 | 0.28 | 0.338492 | 0.123967 | 325 | 5.4 |
Premium Measurement
Measurement of the distance‚ the thickness and the radius of curvature Purpose : To learn how to use vernier caliper‚ micrometer and spherometer to measure internal and external diameters of a pipe‚the thickness of a copper rods‚ and the radius of curvature of spherical lenses. 1) Vernier caliper: As shown in Fig. 1 the main fixed scale in the vernier caliper has 1 mm gradations while th sliding scale (vernier scale) has 0.05 mm gradations. The smallest division of vernier scale is called
Premium Orders of magnitude
increases? Explain. The index of refraction increases which will make the angle of refraction decrease The laser is placed so that the angle of incidence equals 50 degrees. Table 1: Angle of refraction vs the index of refraction Measurement Index of refraction Angle of refraction (degrees) 1 1 50 2 1.1 45 3 1.2 40 4 1.3 36 5 1.4 33 6 1.5 31 7 1.6 29 Conclusion compared to your prediction: Based on the data‚ as the index of refraction increase‚ the
Premium Refraction Snell's law Total internal reflection
DEPARTMENT OF MECHANICAL ENGINEERING ALL Sections must be completed using Block Capitals or typed CODE AND TITLE OF COURSEWORK Course code: MECH1008 Title: OSCILLATION OF A TORSIONAL PENDULUM STUDENT NAME: CHEW KOK HAO‚ DANIEL DEGREE AND YEAR: MENG IN MECHANICAL ENGINEERING LAB GROUP: 1 DATE OF LAB. SESSION: 03 OCT 2011 DATE COURSEWORK DUE FOR SUBMISSION: 10 OCT 2011 ACTUAL DATE OF SUBMISSION: 09 OCT 2011 LECTURERS NAME: Dr. PAUL FROMME PERSONAL TUTORS NAME: Dr. A R GREIG
Premium Measurement Simple harmonic motion Pendulum