There are two sensors‚ which operate in the real-time‚ that will be used - temperature sensor and a humidity sensor to monitor the conditions. The microcontroller will compare the output of the sensors with the preset values and actuate the environmental device respectively. PROBLEM STATEMENT * The inconvenient traditional greenhouse structure – use small window to overcome temperature and humidity problem * Most of work in agriculture is done manually. – Hard to maintain the quality of
Premium Sensor Microcontroller Programmable logic controller
otherwise be lost in their breath. Air with a high water vapour content leaves the lungs - the unavoidable consequence of exposing a relatively large surface area for the absorption of oxygen. Therefore air which is exhaled has a very high relative humidity - close to 100 per cent saturation‚ and it is also at core body temperature - 38°C. If the temperature of the kangaroo rat’s nasal passage is any cooler than 38°C due to the cooler external environment‚ then water will condense before leaving
Premium Humidity Relative humidity Oxygen
CHAPTER 1 Introduction Some farmers who don’t have irrigation system‚ plant rice during rainy season so‚ they have the difficulty of drying their grains after harvest. Aside from these‚ drying the grains under sunlight takes longer time‚ more effort in handling to the drying site‚ scraping or ricking‚ guarding from animals‚ collecting after drying‚ and another is that the possibility of the grains to be mixed with stones‚ leaves of tree‚ and dust in road drying and field drying. There are many
Premium Rice Relative humidity Heat
The Psychometric diagram demonstrates graphically the parameters identifying with water dampness in air. This application note depicts the reason and utilization of the psychometric graph as it influences the HVAC architect or professional. Air includes more or less 78% nitrogen‚ 21% oxygen‚ and 1% different gasses. At the same time air is never dry‚ even in a desert. Two-thirds of the world’s surface is secured with water and this‚ alongside other surface water and downpour‚ keep up low weight
Premium Dew point Psychrometrics Temperature
equilibrium moisture is negligible. An experiment showed that the constant drying rate is 4.5 kg/m2-hr and the falling rate begins at 25% moisture. How long is the drying time. What is the % moisture after 1 hour of drying? 3. Hot Air at 90oC and 40% relative humidity is used as heating medium in a tray drier in order to reduce the moisture content of wet sand from 30% to 5%. Weight of dry sand is 5 kg and the tray dimensions are 20 cm by 60 cm by 3 cm. Critical moisture is 15% and equilibrium moisture is
Premium Psychrometrics Relative humidity Thermodynamics
data sheet Elcometer 116 Whirling & Sling Hygrometer Elcometer 116 Whirling & Sling Hygrometer The Elcometer 116A Whirling Hygrometer is available in °C scale. A guide for Relative Humidity (RH) Calculation is supplied with each instrument. The dewpoint can be accurately obtained using Elcometer 114 Dewpoint Calculator. Elcometer 116 Whirling & Sling Hygrometer Can be used in accordance with: ASTM E 337-B BS 2842 The Elcometer 116C Bacharach Sling Hygrometer is a convenient
Premium Psychrometrics Relative humidity Humidity
cooling power and steam enthalpy can be calculated through the experiment. 2. Introduction & Theory 2.1 Air Conditioning Air conditioning is a system or process for maintaining a living space or industrial facility at the desired temperature and humidity of the air. The SOLTEQ Air-Conditioning Module can be easily couple to the base condensing unit to form a complete refrigeration circuit. This unit involves several components connected by ducting for the air flow. The unit of air conditioning
Premium Air conditioning HVAC Relative humidity
understanding of thermal comfort theory/variables‚ as well as a basic knowledge of the main thermal comfort standards. For this exercise you are to install a datalogger in the main living space of your current home to record temperature and relative humidity over time. The datalogger will be set to sample conditions every 15 minutes‚ and collect one week’s data‚ including a weekend and periods when
Premium Psychrometrics Relative humidity Humidity
Lab Instructions: EX: 21-22 Adiabatic Processes: Humidity- the amount of water vapor present in the air. Absolute Humidity- The amount of water vapor present in a unit volume of air. Relative Humidity-the ration of the amount of water vapor actually present in the air to the greatest amount possible at the same temperature. R. H = Actual Water Vapor content/ Water Vapor Capacity (Maximum Capacity that the air can hold) Saturation Mixing Ratio- The water vapor capacity of air at given temperature
Premium Dew point Water vapor Atmospheric thermodynamics
HVAC Systems: Air Conditioning Dr. Harjit Singh Room 116 Howell Building harjit.singh@brunel.ac.uk Fridays 09.30 – 11.30am Unless otherwise specified For students enquiries: 1 Building Services Engineering: Building Air Conditioning Module (ME5508)‚ Brunel University Introduction to the module • Credit: 15 • Teaching materials: – Provided for the MSc students. – Undergrads: Buy them from the stores. • Assignment: to be handed two weeks before Xmas‚ deadline-28 Jan 2013 • Students
Premium Dew point Psychrometrics Atmospheric thermodynamics