Physioex 9.0 Review Sheet Exercise 1 Cell Transport Mechanisms and Permeability Name: Jeffery Cook Lab Time/Date: 12pm 2/09/2015 Activity 1 Simulating Dialysis (Simple Diffusion) 1. Describe two variables that affect the rate of diffusion. a. Two variables that affect the rate of diffusion are size and whether or not there is an electrical or concentration gradient. 2. Why do you think the urea was not able to diffuse through the 20 MWCO membrane? How well did the results compare with your prediction
Free Diffusion Molecular diffusion Sodium chloride
Experiment 12: Calorimetry and Hess’s Law Purpose: The purpose of this lab is to determine the enthalpy of reaction for the burning of one mole of magnesium in oxygen. Although the reaction is exothermic‚ the ∆HRXN will be determined by using calorimetry and then using Hess’s Law to manipulate the data collected to yield the answer needed. Procedures: Dillon‚ Stephanie. “ Calorimetry and Hess’s Law.” Laboratory Manual. Pearson Publishing‚ 2012‚ pp.168-177. Data and Results Part A
Free Enthalpy Thermodynamics
Study Guide to Help with Laboratory Exam 1 Microbiology 1214 A partial study guide only. Not intended to replace the review sheets or the “Know the following” sections on your labs. These slides are not presented in any particular order. Name this Procedure Identify the two types of bacteria present by shape and gram stain. In a gram stain what is the primary stain? The mordant? The counterstain? How does this differ from a simple stain? Identify the shape and gram stain of the bacteria present
Premium Staining Gram staining Bacteria
Starting Nmap 5.21 ( http://nmap.org ) at 2014-02-23 18:08 Pacific Standard Time NSE: Loaded 36 scripts for scanning. Initiating ARP Ping Scan at 18:08 Scanning 2 hosts [1 port/host] Completed ARP Ping Scan at 18:08‚ 0.63s elapsed (2 total hosts) Nmap scan report for 172.30.0.0 [host down] mass_dns: warning: Unable to determine any DNS servers. Reverse DNS is disabled. Try using --system-dns or specify valid servers with --dns-servers Initiating SYN Stealth Scan at 18:08 Scanning
Premium Unknown unknown
nucleophilic substitution and characterize it by IR spectroscopy. The percent yield of the final product is determined after the synthesis. Procedures: 2.0 mL of 1-bromobutane‚ 3.0 g of sodium benzoate‚ 5.0 mL of water‚ 4 drops of Aliquat 336‚ and a boiling stone were placed in a 50mL round-bottomed flask. The reaction mixture was refluxed for 1 hour and the flask was cooled in a beaker in the water of room temperature. The solid was formed in the mixture and the flask was shaken until it dissolved
Premium Sodium Chemistry Chemical reaction
Lab 1.2 NOUN MAJOR TOPIC 20 DOCTORS 400 PATIENTS NEW DRUG/ TRADITIONAL PROZAC‚ 50/50 PATIENTS NEW DRUG 18 MONTHS CHECKLIST AT TWICE A MONTH TRADITIONAL PROZAC MORE DEPRESS‚ LESS DEPRESS‚ APPETITE‚ SLEEPING? TEST SUPERVISOR 1 PHYSICAL SIDE EFFECT‚ RASHES‚ HIGH BLOOD PRESSURE‚ IRREGULAR HEART RHYTHMS‚ LIVER‚ KIDNEY PROBLEMS TEST SUPERVISOR (PHARMACIST) BLOOD PRESSURE‚ BLOOD TEST RESULT‚ DEPRESSION INDICATORS‚ OWN PATIENCE NOTES PATIENTS MEDICAL PROFILE DR. NOTES LAB 1.3 The school would need
Premium Physician Pharmacology Medicine
Introduction: Nucleophillic substitution is one of the most studied reactions in organic chemistry. In class‚ we are learning about two of these cases: SN1 and SN2. Many other reactions in this class proceed by mechanisms that are best described as somewhat between the two extremes. The SN2 reaction occurs in a single step. The nucleophile simultaneously attaches to the substrate as the leaving group leaves. The reaction displays second-order kinetics; its rate is proportional to the concentrations
Premium Nucleophile
Question 1 1 out of 1 points The volume of a regular cylinder is V = πr2h. Using the value 3.1416 for the constant π‚ the volume (cm3) of a cylinder of radius 2.34 cm and height 19.91 expressed to the correct number of significant figures is _________. Selected Answer: d. 342 Correct Answer: d. 342 Response Feedback: Correct Question 2 1 out of 1 points There are ____________ significant figures in the answer to the following computation: (29.2 - 20.0 ) (1.79 x 105)
Premium Volume
Experiment 1: Error‚ Uncertainties and Measurements Laboratory Report Jan Luke Mendoza‚ Alexis Vienne Munar‚ Paula Murakami‚ Giorla Joanne Negre Department of Math and Physics College of Science‚ University of Santo Tomas Espana‚ Manila Abstract Throughout the experiment the main goal is to find out about the realities in taking measurements‚ that is‚ that there will always be an uncertainty for each acquired value. And to find out and recognize these uncertainties was handled in the
Premium Measurement
Fiber Optic Connector Assembly Oven-Cured Epoxy Application and Connector Assembly: 1. Set the curing oven to the temperature recommended by the epoxy manufacturer. 2. Follow manufacturer’s instructions for mixing the epoxy. 3. Secure needle to the syringe and load the syringe with epoxy while ensuring it is free of air pockets. 4. Insert the needle tip into the back of the connector until it bottoms out against the ferrule. Maintain pressure and slowly inject epoxy until a bead appears on the end
Premium Optical fiber Cable