ITT Technical Institute IT113 Structured Cabling Onsite Course SYLLABUS Credit hours: 4 Contact/Instructional hours: 50 (30 Theory Hours‚ 20 Lab Hours) Prerequisite(s) and/or Corequisite(s): Prerequisite: TB143 Introduction to Personal Computers or TB145 Introduction to Computing Course Description: This course provides the study of industry standards and practices involved in wiring a computer network‚ including media and protocol specifications‚ connection topologies‚ installation‚ testing and
Premium Optical fiber Computer network Structured cabling
Cabling Design IT Solutions has a plan for the cabling and it is based on the specifications in the RFP from the Firm mixed with our own technical knowledge. As stated in the RFP we will only be responsible for specifying the cable plant design and associated equipment. The Firm has stated that they will use their own contractors for installation following the design. We suggest adding 10% more cable to the estimated amount to allow for adjustments adding any unplanned drops and/or changes made
Premium Structured cabling
Cabling ABC Inc. is a company on the rise. With the growth you have already experienced‚ as well as the prospective growth you are expecting to accrue within the coming months‚ you will need to continue moving towards a more robust and reliable network for your employees. It is because of this growth that you will need to choose a wiring solution suitable for those needs. There are several wiring options that are available for what your company needs. It is in this proposal‚ that I will cover
Premium Cable Ethernet Twisted pair
Commercial Building Telecommunication Cabling Standard. Master It 1. Which subsection of the ANSI/TIA-568-C standard would you reference for UTP cabling performance parameters? Answer: ANSI/TIA-568-C.2: Balanced Twisted-Pair Telecommunications Cabling and Components Standard. 2. Witch subsection of the ANSI/TIA-586-C standard would you reference for optical fiber cabling and component performance parameters? Answer: ANSI/TIA-568-C.3: Optical Fiber Cabling Components Standard 3. What is the recommended
Premium Structured cabling Twisted pair Optical fiber
Matching: a. Ethernet-5 b. Horizontal-7 c. Ring-4 d. 62.5/125 Fiber-8 e. Star-3 f. 800 square feet-11 g. 150 square feet-10 h. Cat6 UTP-9 i. Token Ring-2 j. Bus-1 k. Plenum-12 l. Backbone-6 Master it: You are asked to design a network for a company fully occupying a three-story office building using a traditional star network topology. The equipment room‚ containing the company’s server‚ is located on the first floor and telecommunications rooms and
Premium Network topology Computer network
Structured Cabling Technology and Market Assessment January 13‚ 2013 When we started researching the structured cabling market a few months ago‚ it seemed like not much had changed in the past three years. Some of the individuals we interviewed for this report thought so‚ too. But as it turns out‚ there have been many changes to the market. The recession reduced investment‚ led to the cancellation of many projects‚ and those that continued worked under reduced budgets. This‚ in addition to changes
Premium Optical fiber Marketing Ethernet
shaded in GREY (e.g. the “Insert Company Name Here” field below). Form shading does not print. Be sure to change all text to BLACK before printing or sending. Insert Company Name Here Request for Proposal for a Data Center Structured Cabling Solution Insert Date of Issue Here Table of Contents 1 Statement of Work 3 1.1 Purpose 3 1.2 Coverage & Participation 3 2 General Information 3 2.1 Original RFP Document 3 2.2 The Enterprise 3 2.3 Existing
Premium Request for proposal Proposal Proposals
Visual System for the NBK – Oncology Hospital. The report will outline Data Communications‚ Telephony‚ Audio Visual (AV) systems and server room design basis proposed for the project. The Telecommunication systems shall be based on converged Structured Cabling system. The IP telephony and Physical security systems shall be designed to communicate over the same network Infrastructure and utilizing wherever possible Power-over-Ethernet (PoE) technology. 6.2. List of Abbreviations ICT Information
Premium Structured cabling Physical security Telecommunication
IT113 Homework 1 Structured Cabling Unit 1 Homework Exercise 1.1 1. What industry standards body and standards series numbers do you need to reference for Ethernet applications and cabling? The IEEE maintains the industry standards for Ethernet Protocols (or applications). This is part of the 802.3 series of standards and includes applications such as 1000Base-T‚ 1000Base-SX‚ 10GBase-T‚ and 10GBase-SR. 2. What are the different types of category 6 cables and what should be recommended this
Premium Ethernet Computer network Twisted pair
equipment‚ and often emerge as a result of issues discovered during regular maintenance. 1.2 General Scope of Work LC Comm. proposes to produce contract specifications and construction drawings for all building spaces as well as the communications cabling system. This will include the plan views of all equipment rooms‚ labs‚ MDF/IDFs and the elevation views of equipment racks and cabinets. In general‚ this includes the following: 1.2.1 Participation in the design process. LC Comm will work with the
Premium Structured cabling Cable Requirements analysis