Review for Bio 103 Lab Midterm Read the lab manual and study your worksheets. Vocabulary: Metric system‚ percent error‚ systematic error‚ random error‚ accuracy‚ precision Cylinder‚ beaker‚ pippette‚ balance‚ meniscus Field of view‚ inversion‚ total magnification‚ depth of field‚ par focal Microscope parts: eye piece‚ body tube‚ arm‚ nosepiece‚ objectives‚ stage clips‚ mechanical stage‚ diaphragm‚ condenser‚ fine and course adjustments‚ light stage‚ base Protein‚ peptide bond‚ simple sugar
Premium Chemistry Glucose Units of measurement
Physics Lab Report 1. For the wavelength measurement of different colors in the Hydrogen spectrum done in the lab‚ tabulate your data recorded along with the wavelength calculations performed for all colors in the spectrum. (2 points) Line Color a_left (m) a_right (m) a_average (m) sinq nm Red 0.235 0.27 0.2525 0.182145 5.47E-09 Green-Blue 0.17 0.33 0.25 0.180505 5.42E-09 Indigo 0.16 0.35 0.255 0.18378 5.52E-09 Violet? 0 0 0 0 0 To find the wavelength for all of the colors in this lab we used two
Free Light Color Electromagnetic radiation
and close the top end of the tube‚ fold it and tie a string over the top so it is fully sealed. Once done we cleaned the outside of a tube by rinsing it and then using paper towels to dry it. These steps were repeated for the egg white‚ sucrose and starch solutions. Then immediately weigh the tubes on an electronic scale (make sure it is set to 0) using grams and mark down the readings. Then place each tube in a 250ml beaker with enough distilled water to cover all of the tube. Mark each beaker so
Premium Osmosis Diffusion Chemistry
Enzyme Lab Report Introduction: Enzymes are proteins that enable chemical reactions. In the enzyme lab‚ the effects of concentration‚ temperature and pH on the functionality of the enzyme catalase. The enzyme lab was also about measuring reactions by capturing the oxygen that was generated by the reaction. Materials and Methods: Experiment 1‚ 2‚ & 3 Experiment 1 examined the effects of concentration on catalase activity. Experiment 2 examined the effects of concentration in temperature
Premium Catalase Enzyme Oxygen
NANYANG TECHNOLOGICAL UNIVERSITY [pic] ANALOG CIRCUIT DESIGN LAB312 REPORT (S2-B4a-04) Student name: xxx Student no: xxx Group: xxx Date of submission: xxx TABLE OF CONTENTS 1. Introduction……………………………………………………….3 • 1.1 Background…………………………………………..3 • 1.2 The Capture Work Environment……….…………. 4 • 1.3 The PSPICE A/D Simulation Environment……… 5 • 1.4 Objective……………………………………………. 6
Premium Electronic design automation Electronic engineering Circuit diagram
Name: Nikia Martinez Class: Biology 240L L3-1201 Assignment: Electrocardiography Lab Report Due: April 3rd 2012 Professor: Dr. B. Schoffstall Introduction In a normal human being the heart correctly functions by the blood first entering through the right atrium from the superior and inferior vena cava. This blood flow continues through the right atrioventricular valve into the right ventricle. The right ventricle contracts forcing the pulmonary valve to open leading blood flow through the pulmonary
Premium Heart
the practical test. Therefore‚ a lab coat‚ safety gloves with clean hands and goggles must be worn before starting the experiment. The initial room temperature should be calculated using a thermometer and a marker is used to name beakers 1 and 2. Divide the 10 test tubes into two groups and name them 1-5 in both groups. 5 different stopwatches are used to record the time for the disappearance of the blue-black color in test tubes‚ name them 1-5 also. Stopwatch 1 corresponds to test tube 1 in beaker
Premium
The purpose of the lab is to identify the compound based on a constant composition by performing a serious of tests. The hydrate is solid crystals compound and appears to be dry: since an ionic compound (salt) is crystallized from an aqueous solution (water)‚ by heating the hydrate the water is released from ionic structure; therefore it is possible to measure the weight of the ionic compound and calculate its ratio to the liquid in the hydrate. The goal of the lab is to establish the identity
Premium Chemistry Molecule Water
Lab Report Microscopic Study: Investigating Osmosis in Red Blood Cells Lab Report Investigating Osmosis in Red Blood Cells Introduction: The flow of water across a permeable membrane is called osmosis‚ and during this process‚ water moves down its concentration gradient. A solution surrounding a cell is hypertonic if it contains more solute particles than the inside of the cell‚ and the water will move out of the cell into the surrounding hypertonic solution by osmosis. If the solution
Premium Red blood cell Cell membrane Blood
After this‚ pour the liquid into yet another clean test tube and think about what would happen if more liver was placed in this liquid. Place the liver into the liquid mixture of hydrogen peroxide and liver and the new mixture didn’t fizz as much as with just the hydrogen peroxide and one thing of liver
Premium Oxygen Enzyme Hydrogen peroxide