To prepare and study the kinetics of the interconversion of some of the isomers of a typical coordination compound. INTRODUCTION: Isomerism played a central role to establish the basic concept in coordination chemistry while reaction kinetics of coordination compound is known as the area of continuing intense research activity. The mechanism of the reactions of coordination compounds relevance to enzyme reactions where the active site is being involve in coordination to a metal ion. PROCEDURE:
Premium Chlorine Hydrochloric acid Solvent
is the capacitative reactance‚ R is the resistance‚ and ω = 2π f ( f is the linear frequency). Apparatus • PC with DataStudio installed • Science Workshop 750 USB Interface Box • Power Amplifier • Voltage Sensor • AC/DC Electronics Lab Board • LCR meter • Connecting patch cords Experimental Procedure The experimental procedure can be divided into three parts: Part I: Using a Frequency Scan to Determine the Resonance Frequency • The first
Premium Alternating current Inductor Electrical resistance
Recrystallization and Melting Points Organic Chemistry 2423 Lab Report: Recrystallization Abstract: The purpose of this lab was to purify an unknown compound by recrystallization. Taking an unknown compound and identifying it by purifying it from its impurities through the use of hot gravity filtration. Then to determine the unknown you were to take the melting point. An unknown compound was recrystallized from hot water to produce 0.99 grams (67% recovery). The pure unknown compound had a melting point of 127
Premium Temperature Solubility Solid
References: a) http://en.wikipedia.org/wiki/Reynolds_number b) http://www.engineeringtoolbox.com/reynolds-number-d_237.html c) http://www.engineeringtoolbox.com/laminar-transitional-turbulent-flow-d_577.html d) http://www.slashdocs.com/prqt/lab-report-osbourne-reynolds-apparatus.html APPENDIX The Reynolds Apparatus that was used during the experiment.
Premium Fluid dynamics Fluid mechanics Viscosity
The Virtual Lab – ELISA Test Lab: Immunology 09/04/2013 Instructors: Dr. Charlie Wilson Written by: Dipen Patel I. Objective: The purpose of the lab was to learn the procedure of performing an ELISA test to determine whether a particular antibody is present in a patient’s blood sample. ELISA is an abbreviation for “Enzyme-linked Immunosorbent Assay." II. Introduction: The interaction of antigen and antibody outside the body can be used to determine if patient
Premium Antibody Immune system ELISA
I.Purpose The purpose of this lab is to show how potential energy and kinetic energy is shown and transferred using a model rollercoaster. This lab also demonstrates the Law of Conservation of Energy. II.Introduction Potential and Kinetic energy have a very big relationship. The Law of Conservation of Energy states that “Energy cannot be destroyed or created‚ but can be transformed or transferred.” This lab will help demonstrate this law and show the conversion between Kinetic and Potential
Free Energy Potential energy Conservation of energy
One of the main learning experiences of this lab is to learn the importance of calibrating a sensor. In most cases‚ a sensor will not have an output that is exactly what you need. An example of this is a strain gage. A stain gage gives back a voltage‚ but with that given voltage a distance can be found. Introduction: In this experiment‚ the QNET-MECHKIT was used. This board has multiple compact sensors that can be used for experiments. For this lab we will be using the strain gage to find the
Premium Metrology Measurement Angle
Crystallization: Lab Report Theory/Introduction The purpose of this lab is to understand the concept of purification through crystallization. Crystallization is the process of purifying a substance‚ with the most adequate solvent. The process of crystallization came to be based on the principle of solubility. First‚ we must choose a solvent. The solvent is crucial to crystallization because it’s what will allow impurities to dissolve. Therefore‚ when selecting a solvent it is important that it
Premium Solubility Chemistry Solution
Since the Grignard reagent can easily react with water‚ all glassware including the 25 ml round bottom flask‚ magnetic stir bar‚ 3 and 5 ml conical vial‚ 50 mL Erlenmeyer flask‚ claisen adapter‚ drying tube and 5 glass pasteur pipets were first added to a 250mL beaker and placed in the oven for 30 minutes. After the completion of the thirty minutes‚ 0.150 g of shiny magnesium turnings and a stir bar was first added to the round bottom flask and the claisen adapter along with the drying tube packed
Premium Chemistry Water Solvent
Nervous System lab was designed to measure reaction times by using a variety of tests that affect the heart rate. These tests were the startle‚ stroop‚ Valsalva maneuver‚ diving reflex‚ and a test of our choice. The test our group chose to measure the heart rate in response to doing a trust fall to anticipate the stress right before the fall. To begin this lab we chose a participant‚ and then hooked their finger up to the pulse transducer sensor. Using the chart 5 program on the lab computer the participant’s