mixed with hydrogen peroxide)Dependent: the activity of the catalase‚ reflected by the rate at which oxygen is evolved‚ measured at every time the pH is changed.
Premium Enzyme Metabolism Catalysis
References: a) http://en.wikipedia.org/wiki/Reynolds_number b) http://www.engineeringtoolbox.com/reynolds-number-d_237.html c) http://www.engineeringtoolbox.com/laminar-transitional-turbulent-flow-d_577.html d) http://www.slashdocs.com/prqt/lab-report-osbourne-reynolds-apparatus.html APPENDIX The Reynolds Apparatus that was used during the experiment.
Premium Fluid dynamics Fluid mechanics Viscosity
References: http://webs.mn.catholic.edu.au/physics/emery/measurement.htm#Measurement http://www.digipac.ca/chemical/sigfigs/experimental_errors.htm http://www.tsb.gc.ca/eng/rapports-reports/rail/2011/r11v0057/r11v0057.pdf
Premium Experiment Science Design of experiments
I.Purpose The purpose of this lab is to show how potential energy and kinetic energy is shown and transferred using a model rollercoaster. This lab also demonstrates the Law of Conservation of Energy. II.Introduction Potential and Kinetic energy have a very big relationship. The Law of Conservation of Energy states that “Energy cannot be destroyed or created‚ but can be transformed or transferred.” This lab will help demonstrate this law and show the conversion between Kinetic and Potential
Free Energy Potential energy Conservation of energy
McLean 1 Creating Acetylene Gas Introduction The purpose of the lab was to determine the ratio of air to acetylene results in complete combustion of acetylene gas. The balanced chemical equation for this experiment was C2H2(g) + O2(g) --> CO2(g)+ H2O(l). Complete combustion is the reaction of an element or compound with oxygen to produce the most common oxides and energy. Complete combustion occurs when the fuel and oxygen combine in exact proportions to completely burn the fuel
Premium Oxygen Combustion
Abstract This lab was performed in order to discover the activity of the enzyme catecholase in different pH levels as well as its absorbance in differently concentrated solutions. A spetrophotometer was used to measure the absorbance of the enzyme catecholase in different pH solutions as well as to measure the absorbance of catecholase in solutions with different concentrations of potato juice and phosphate buffers. Absorbance of the enzyme catecholase was at an optimum level when pH was close
Premium PH Buffer solution Enzyme
following: pH strips Sample reservoirs of solutions with varying pH Laboratory Notebook pH paper Background pH stands for potential hydrogen. This is a measure of the acidity or basicity of a solution. Acidic and basic are two extremes that describe a chemical property chemicals. Mixing acids and bases can cancel out or neutralize their extreme effects. The pH scale is a set of standard solutions whose pH is established by international agreement. A substance that is neither acidic nor basic
Premium PH
Enzyme action is the simple mechanism by which enzymes catalyse chemical reactions. This begins with the binding of the substrate to the active site on the enzyme. The binding of the substrate to the enzyme causes changes in the distribution of electrons in the chemical bonds of the substrate. This then causes the reactions that lead to the formation of products that are then released from the enzyme surface to regenerate the enzyme for another reaction cycle. The active site has a unique shape that
Premium Enzyme Chemical reaction Catalysis
is involved with the cannon being fired then the force of gravity would cause the cannon to start to slow down‚ wouldn’t go as far and the direction or trajectory of the cannon ball would be a curved line going down. Purpose: The purpose of this lab is to give the student a better understanding about projectile motion and to understand Newtons theories and laws of motion. We will be firing the plastic ball from the projectile launcher three times from eight different angles from the ground &
Premium Range of a projectile Force Newton's laws of motion
One of the main learning experiences of this lab is to learn the importance of calibrating a sensor. In most cases‚ a sensor will not have an output that is exactly what you need. An example of this is a strain gage. A stain gage gives back a voltage‚ but with that given voltage a distance can be found. Introduction: In this experiment‚ the QNET-MECHKIT was used. This board has multiple compact sensors that can be used for experiments. For this lab we will be using the strain gage to find the
Premium Metrology Measurement Angle