load test Aim: To determine the strength characteristics of a rock using the point load test and visual judgement. Materials Loading device Loading frame Pump Ram Platens Rock Caliper Method (Standard‚ 2007) 1. Measure the dimensions of the rock which includes the diameter and length 2. Find the length to diameter ratio to determine which test will be used. If the ratio is greater than 1 use diametrical test. But if the ratio is between 0.6 and 1 use axial test 3. The axial test was
Premium Geology Mineral
3. LABORATORY TESTS USED TO STUDY THE STRENGTH OF CALCARENITES There are 3 distinct methods or tests used to determine the strength of calcarenite which are needle penetration test‚ unconfined compression test‚ and direct shear box test. 3.1. Needle penetration test This form of test is done on site on an outcrop rock that is not disturbed; this is usually done by extracting a sample material for oncoming laboratory work. The penetration tests are done on two different sections of outcrop with an
Premium Shear stress Shear stress Shear strength
The Charpy impact test‚ also known as the Charpy V-notch test‚ is a high strain-rate test which determines the amount of energy absorbed by a material during fracture. The Charpy test specimens were made according to the dimensions of standard ASTM A370. One of the main reasons for concern for natural composites laminates generally is the low values
Premium Tensile strength Management Beam
To test the aptitude of the person‚ it requires manual dexterity whereby a joint in a person’s arm is controlled and predetermined stress in which the direction of the arm and the joint moves will lead to the deflection and it will be measured (Wagner‚ 1977). This experiment is widely known all over the world and it is usually used especially to capture the motor performance in a variety of situations. According to Bryden and Roy (2005)‚ they did the study to examine the influences of handedness
Premium Sitting Handedness Analysis of variance
Detecting ECG Daniela Paszkiewicz and Lyndsey Wessel Abnormalities in VO2 Max Tests ECG “An electrocardiogram (ECG) is a medical test that detects cardiac (heart) abnormalities by measuring the electrical activity generated by the heart as it contracts.” http://www.istockphoto.com/file_thumbview_approve/3733 698/2/istockphoto_3733698-electrocardiogram-ecg-ekgwith-human-heart-on-screen.jpg Function of Electrocardiograph Electrocardiograph measures a patients ECG ECG can help detect a
Premium Heart Cardiology Cardiac electrophysiology
balance or scale used in testing fine and coarse aggregates shall have readability and accuracy as follows: For fine aggregate‚ readable to 0.1 g and accurate to 0.1 g or 0.1 % of the test load. For coarse aggregate‚ or mixtures of fine and coarse aggregate‚ readable and accurate to 0.5 g or 0.1 % of the test load. 2. Sieves – the sizes and apertures appropriate to the specification of the material being tested‚ complying with BS 410: For coarse aggregate‚ standard sieve size of 50.0 mm‚
Premium Construction aggregate
no need for distillation. Next‚ a solubility test was given. When one drop of the unknown liquid was added to about 2 mL of water‚ the sample was tested to be soluble due to the dissolubility between the two compounds. By following the chart that was given on the sheet‚ the pH of the solution was tested. Since the two litmus did not changed color‚ the sample was identify to have a low molecular weight and a neutral substance. Based on the solubility test‚ some possible
Premium Acid Chemistry Acetic acid
Stomach Torsion in Dogs and How to Prevent It By Ron M. Ayalon Oct 1‚ 2014 Also known as gastric torsion‚ bloat‚ and GVD (gastric dilation and volvulus syndrome)‚ stomach torsion is one of the most serious of canine medical conditions. A dog that develops torsion must be seen by a veterinarian immediately in order to save his or her life. Without treatment‚ mortality is effectively 100%. Stomach torsion is much more common in large dog breeds than it is in medium or small‚ although theoretically
Premium Stomach Dog Dog breed
The experiment was separated into four stages‚ the first being preparation of cell competency. In this stage two vials were placed in ice baths‚ one vial containing 50 µL of E. coli and the other containing a CaCl2 solution. 630 µL of the CaCl2 solution was then transferred to the E. coli vial‚ using a sterile pipet. After tapping the tube to mix the solution‚ it was then returned to the ice bath to continue incubation for at least 10 minutes. The cell competency preparation was carried out by the
Premium Escherichia coli Bacteria DNA
Geotechnical Engineering B Lab Report Student Name: Zhang Jie Student Number: 33381954 Level: 6 Group: 4 Date: 2015.04.15 Lecturer: Steve Rogers CONTENT Constant Head permeability test 3 ABSTRACT 3 INTRODUCTION 3 EXPERIMENTAL PROCEDURE 4 CACULATIONS AND RESULTS 4 DISSCUSSION
Premium Soil mechanics Aquifer Hydrology