Syllabus: 1. TELECOM BRANCH 2. CIVIL BRANCH 3. ELECTRICAL Pattern of syllabus: The whole syllabus will carry Two section of Technical subjects and General Ability Test. NOTE: General Ability Test are common for all branch (TELECOM ‚CIVIL ‚ELECTRICAL ) Free download BSNL jto syllabus Syllabus: TELECOM BRANCH SECTION – I (Total = 50 Question ) 1. Materials and Components Structure and properties of Electronic Engineering materials‚ Conductors‚ Semiconductors and Insulators‚ Magnetic‚ Ferroelectric
Premium Transformer Electrical engineering Electronic engineering
- Step 108.4) 4 Check Readiness for Individual Tests (GP - Activity 108.4.1) 4 Perform Individual Tests (GP - Activity 108.4.6) 4 1. Outdoor Circuit Breaker (SF6) 4 2. Outdoor Disconnector 9 3. Current Transformer 11 4. Voltage Transformer 19 5. HV connections 23 6. Power Transformer 26 7. MV Cable 38 8. Substation Earthing Resistance 40 9. Interlockings 44 Hot Commissioning (GP - Step 108.5) 45 Check Readiness for Hot Commissioning (GP - Activity 108.5.1) 45 10. Start Up (GP - Activity
Premium Circuit breaker Transformer Electricity distribution
achieved using an auxiliary switch‚ a diode and a coupled inductor. The main drawback of the circuit is that in order to achieve ZVS in one switch‚ a number of components have to be added to the circuit. In [12]‚ ZVS is achieved in the switch using a transformer‚ thus the voltage stress is reduced. In this
Premium Alternating current Direct current Transformer
THE UNIVERSITY OF NEW SOUTH WALES FINAL EXAMINATION JUNE/JULY‚ 2001 ELEC4240/ELEC9240 POWER ELECTRONICS 1. Time allowed: 3 (three) hours 2. This paper has six questions. Answer any four. 3. All questions are of equal value. 4. A separate examination book should be used for each question. 5. Candidates may bring only slide rules‚ drawing instruments and approved electronic calculators into the examination room. 6. Answers must be written in ink. Except where
Premium Alternating current Root mean square Transformer
5.2 Simulation model The simulation circuit is as shown in Figure 5.1 for proposed CSR-HFL inverter. Here the proposed CSR-HFL inverter is Fuzzy-controller which gives pulse generator to generate pulses at give instant to operate the proposed CSR-HFL inverter. Figure: 5.1 Simulation model for proposed CSR-HFL inverter 5.3 Simulation results Figure 5.2 and 5.3 shows the waveforms of the CSR-HFL inverter with open-loop control when input voltage UD = 48 V and output ac voltage Vo = 50V. The reference
Premium Alternating current Electric motor Direct current
sensing section and this could seriously affect the circuit’s performance. [pic] A regulated 9V/500mA power supply that can be used for powering the basic fire alarm circuit and its modified versions is shown above. Transformer T1 is a 230V primary‚ 12V secondary‚ 500mA step down transformer. D1 is a 1A bridge which performs the job of rectification. Capacitor C1 filters the rectifier output and C2 is the AC by-pass capacitor. IC1 (7809) is a 9V fixed positive voltage regulator. The output of the rectifier+filter
Premium Vacuum tube Rectifier Transformer
suppression network is thus used to suppress these electrical noises. HISTORY : Light dimming is based on adjusting the voltage which gets to the lamp. Light dimming has been possible for many decades by using adjustable power resistors and adjustable transformers. Those methods have been used in movie theatres‚ stages and other public places. The problem of those light controlling methods have been that they are big‚ expensive‚ have poor efficiency and they are hard to control from remote location. The
Premium Alternating current Resistor Lighting
ENGINEERING‚ PROCUREMENT AND CONSTRUCTION PROJECT OF THERMAL POWER PLANT Company mission: To develop‚ implement innovative construction and on site implementation methods to meet the best industrial standards and to continuously improve on cycle time reduction and modernization of construction methods applicable for the power‚ process and infrastructure industries. MAIN PLANT AREAS a) Bunker bay b) Turbine generator bay Bunker Bay Coal bunker These are in
Premium Electric power transmission Coal Transformer
CALIFORNIA STATE UNIVERSITY‚ NORTHRIDGE WiTricity: Wireless Power Transfer A Graduate Project submitted in fulfillment of the requirements For the Degree of Master of Science in Electrical Engineering By Pranit Yeole MAY 2013 The Graduate Project of Pranit Yeole is approved: _________________________________________________ Dr. Ali Amini ____________ Date _________________________________________________ Dr. Ahmad Bekir ______________ Date _________________________________________________
Premium Magnetic field Transformer Electric power transmission
Industrial Supply Service Connection Charges Rs. 350/- per KW Rs. 500/- per KW Rs. 500/- per KW Rs. 1000/- per KW Rs. 750/- per KW Rs. 2500 per KVA of contract demand If the network expansion cost (extension of HT/LT lines and proportionate transformer installation cost) is more than the above charges then higher of the two will be charged. The detailed procedure for release of new connections has already been circulated vide sales circular S.C No. U-73/2005. All the Sales circulars on the subject