Mechanical and Aerospace Engineering Department Polytechnic Institute of New York University ME6213 Introduction to Solid Mechanics 1.Buckling of Columns 2.Deflection of Curved Beams Date of Experiment:_______ Date of Lab Report Submission: _______ This lab report submission is approved by: Amith Deshmukh | Signature:_________ | Bhavesh Joshi | Signature:_________ | Anoop Kumar | Signature:_________ | Sriniket Srinivas Achar | Signature:_________ | Experiment 1 – Buckling of
Premium Column Buckling
ABSTRACT. In this experiment‚ we test factors which affect friction. We pulled a wood block across a surface to determine whetherthe surface area ofthe block orthe type ofsurface affectsfriction. We found that the surface area of the block did not change the coefficient of kinetic friction‚ while the types of materialsin contact were directly related to the coefficient of kinetic friction. INTRODUCTION Friction is a part of our everyday life. Nearly every movement we make involves friction
Premium Friction Force Classical mechanics
Chemistry Lab Report Water Hydration Introduction: A hydrated crystal or hydrated occurs when water becomes tightly attracted to a metal salt base on it’s polarity. The water molecules maintain integrity as molecules‚ however they are considered to be part of the formula of the hydrate. When the hydrate metal salt crystal is heated‚ the attractions to the water are broken by the heat energy and the water escape from the crystal. After heating the salt crystal is called as anhydrous‚ which
Premium Water Salt Sodium
Introduction! ! The Michelson Interferometer is commonly used to determine the wavelength of light or measure very small distances. It was invented by Albert Abraham Michelson and is commonly used in optical interferometry‚ a branch of physics involving a family of techniques one could use to extract information about waves by superimposing them. ! ! The original application of the Michelson Interferometer was to the famous Michelson-Morley experiment in 1887. Prior to Einstein’s
Premium Light Diffraction
Lab Report An enzyme is a protein that speeds up the rates of chemical reactions. They recognize‚ bind‚ and change specific reactants. They do not change so they can catalyze the same reaction again and again. Activation energy is the amount of energy needed in order to begin a chemical reaction. A Catalyst is a substance that increases the rate of a chemical reaction without itself undergoing any permanent chemical change. Catalysts are substances or a substance that configures another substance
Premium Chemical reaction Chemistry Catalysis
Low Voltage Analog Circuit Design Techniques: A Tutorial IEEE Dallas CAS Workshop 2000 Edgar Sánchez-Sinencio March 27‚ 2000 http://amsc.tamu.edu/ Texas A&M University Analog and Mixed-Signal Center Low Voltage Analog Circuit Design Techniques: Roadmap Low voltage (LV) power supply circuit design techniques are addressed in this tutorial. In particular: (i) Introduction; (ii) Transistor models capable to provide performance and power consumption tradeoffs; (iii) Low voltage
Premium Transistor MOSFET Electronic engineering
FIELD-PROGRAMMABLE GATE ARRAY A field-programmable gate array (FPGA) is an integrated circuit designed to be configured by a customer or a designer after manufacturing—hence "field-programmable". The FPGA configuration is generally specified using a hardware description language (HDL)‚ similar to that used for an application-specific integrated circuit (ASIC) (circuit diagrams were previously used to specify the configuration‚ as they were for ASICs‚ but this is increasingly rare). Contemporary
Premium
Introduction: During this unknown lab report various test were performed to differentiate microbes from each other and to compare metabolic and biochemical process. The gram stain distinguishes between Gram positive and Gram negative bacteria based on the composition of the cell wall. The Gram stain procedure distinguishes between Gram positive and Gram negative groups by coloring these cells red or violet. Gram positive bacteria stain violet due to the presence of a thick layer of peptidoglycan
Premium Bacteria Adenosine triphosphate
INTRODUCTION The measurement of fluid flow is very important in our daily life from measurements of blood-flow rates in human artery to the measurement of liquid oxygen in a rocket. In this experiment‚ students are to adapt to various ways to measure the flow of essentially incompressible fluids by using the flow measuring apparatus. Students will also be able to understand the application of Bernoulli’s equation in this experiment. The flow is measured by using a venture meter‚ an orifice meter
Premium Fluid dynamics Mass flow rate
Electrical Machines Electrical Machine Stationary Transformer Rotating DC AC Motor Induction Generator Motor Generator Synchronous Motor Generator Electrical Generator / Motors An electric generator converts mechanical energy into electrical energy. An electric motor converts electrical energy into mechanical energy. Mechanical Input Electrical input ELECTRICAL MACHINES Generator ELECTRICAL MACHINES Motor Electrical Output Mechanical output
Premium Magnetic field Electricity Electrical generator