Preview

Cabling and Factor Tools

Good Essays
Open Document
Open Document
285 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
Cabling and Factor Tools
Unit 5 Assignment Cabling Factors and Tools

When choosing cabling for a network, there are several factors to consider: cost, Expansion capabilities, bandwidth, signal attenuation, and EMI (Electro- Magnetic Interference).
Each type of cable has different specifications that affect these factors, and each organization has different needs. Considering Cable system factors is very important for building a network system that meets an organization’s needs. Now in the design of the installation of your cabling a poorly designed or installed network cabling set-up can reduce network performance. Today, data centers are growing and maturing, and cable management is becoming an important consideration. Proper cable management allows the fast identification of all system connections both at the physical layer and at the documentation level; good cable management also improves the maintenance of hardware equipment and the installation of new one; and finally, structured cabling management makes possible the effective cooling of the data center.
You also have to consider fire and safety issues, for where you will be installing the cables. How they will be run throughout the building, will the cables be near other electrical cables and can it cause interference. Will the cableling be properly used under standards and local codes?
And if not what would have to be done in order to makes sure it’s all up to code, and fire safety inspections. Some of the tools that will be needed for your installation will be Crimpers, Wire cutters/Stripper, Cable ties, Punch-down tools, voltage dectors, testing tools for when done. Also it would be smart to have a drill and bits/paddle bits, pliers, gloves, flashlight, and a tape measure. These are just a few things that would be useful to have.

You May Also Find These Documents Helpful

  • Good Essays

    NT1310 Unit 9 Lab 1

    • 1254 Words
    • 4 Pages

    The new structure has been given a grant to make its network state of the art by making it a fiber optic network. The topics of discussion that will be mentioned in this paper are the hardware that will be necessary for the inside and outside of the building and how we would expand the fiber to an adjacent building if it is built. Another topic to be discussed will be describing the safety procedures that will be following during the installation.…

    • 1254 Words
    • 4 Pages
    Good Essays
  • Satisfactory Essays

    NETW410 Week 3 Lab Report

    • 532 Words
    • 2 Pages

    2. Will the current horizontal cabling suffice for the new network? If it will not, what type of cable should be used for the horizontal cabling? Provide detailed specifications for this cable. (10 points)…

    • 532 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Nt1310 Unit 4.1 Case Study

    • 2532 Words
    • 11 Pages

    Using the description of Network C and Figure 4- 6, create a cabling solution for this network that meets the owner’s needs. Justify your choices.…

    • 2532 Words
    • 11 Pages
    Good Essays
  • Satisfactory Essays

    JG NT2640

    • 333 Words
    • 1 Page

    1. Which one of the following answers is most accurate about the cabling of a typical modern Ethernet LAN?…

    • 333 Words
    • 1 Page
    Satisfactory Essays
  • Satisfactory Essays

    unit 5 assignment1

    • 309 Words
    • 2 Pages

    What type of install is the cable going into? Is everything in a fixed position? If you have an install where items are moved around without being disconnected, using highly flexible cable is necessary. Cables in these scenarios need to be flexible to meet those demands of mobility, and also for the life of the wire so that it does not crack, break, fray or short. We had a job at a university where we moved flat panels on a track system to create different screen sizes, and for that we had to make sure the cable would meet the demand.…

    • 309 Words
    • 2 Pages
    Satisfactory Essays
  • Better Essays

    Twisted pair comes in two varieties, shield (STP) and unshielded (UTP). The name describes the cabling completely, there are two pairs of cables twisted together in order to reduce cross talk between the wires. Phone line in houses and businesses still use USP for analog telephone and fax machines to this day. UTP comes in many varieties and is constantly being built upon. Cat5e, Cat6, Cat7, and now Cat 8 cables are available to businesses and end users today. With this standard pushing 40 Gigabytes per second the only question remains is what are the full limitations of copper? STP is nothing more than adding extra shielding to reduce crosstalk in the UTP standards. These are extremely cost effective networking cables and are easier to install than coax. Twisted pair is more…

    • 1357 Words
    • 6 Pages
    Better Essays
  • Satisfactory Essays

    Expander installed and now be able to accommodate 6 devices, but at a max of 3Gbit/s throughput…

    • 603 Words
    • 3 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Nt1310 Unit 4 Assignment

    • 381 Words
    • 2 Pages

    In this paper we will discuss two different cabling solutions (copper & fiber), and in what situations you would choose one over the other. One might be better for one type of application while the other might be a better fit, depending on the situation. They each have their own advantages which we will discuss in the following paragraphs.…

    • 381 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Nt1310 Unit 4 Lab 1 Essay

    • 553 Words
    • 3 Pages

    First off I think since our building is going to be connected to a lot of students I believe that our best choice of cabling to connect to the building will be fiber-optics. This way the students and professors can access whatever they need as fast as possible from any location on campus. On the inside to save money I would run cat5e cables to each individual device. Running fiber-optics to each computer in the computer labs would take a lot of work since fiber is so hard to handle. This will allow them to do all kinds of test involving the network while not being too budget heavy.…

    • 553 Words
    • 3 Pages
    Satisfactory Essays
  • Powerful Essays

    Scalability: The network design is scalable so that more network cable equipment can be added if needed and as funding becomes available without having to redo the installed network…

    • 768 Words
    • 4 Pages
    Powerful Essays
  • Good Essays

    NT 1310 Unit 5 LAB 1

    • 417 Words
    • 2 Pages

    If I choose to design the new building with a wired network the main benefit is there would be a low chance on interception. Choosing a wired network will also have a lower risk of security issues; reliability and speed are primary benefits as well when using physical connections in a wired network. The basis of the new building will relay on loads of data to be moveable that is why a wired network allows the control. Wired LANs provide superior performance. A wired network is also more cost effective, the items needed to build such as Ethernet cables; hubs and switches are very inexpensive. But by using a wired network Ethernet cables, hubs and switches are extremely reliable and inexpensive.…

    • 417 Words
    • 2 Pages
    Good Essays
  • Good Essays

    It 220 Lab 9.1

    • 426 Words
    • 2 Pages

    38. What type of networking cables would you use in a new building? Discuss the issues related to your selection.…

    • 426 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Nt1310 Unit 1 Assignment

    • 987 Words
    • 4 Pages

    2. What are the different types of category 6 cables and what should be recommended this network?…

    • 987 Words
    • 4 Pages
    Good Essays
  • Satisfactory Essays

    Transmitting Bits

    • 2211 Words
    • 6 Pages

    Microphones, PA systems, Audio cables, Power cables, and RG-6 Cables used for television. There are three reasons, that I can think of, to use shielded cable instead of unshielded. Radio Frequency Interference (RFI) was the earliest interference engineers had to deal with. Early radio signals easily found their way into devices. Coaxial cables and shielded twisted pairs using copper can eliminate…

    • 2211 Words
    • 6 Pages
    Satisfactory Essays
  • Satisfactory Essays

    APPENDIX A STUDY ON TRAINING AND DEVELOPMENT OF EMPLOYEES AT KKP SPINNING MILLS NAMAKKAL QUESTIONNAIRE 1. Name : 2. Age (In Year) a. 18-20 b. 20-25 c. 25-30 d. 30-40 d. above 40 3. Gender a. Male b. Female 4. Martial Status a. Married b. Unmarried 5. Designation a. Manager b. Assistant Manager c.…

    • 333 Words
    • 2 Pages
    Satisfactory Essays

Related Topics