Explain Why Is It Important To Work Accurately And The Consequences Of Submission Of Inaccurate Results
1- Why is it important to work accurately and the consequences of submission of inaccurate results?
All work must be very accurate as the results may need to be used in prosecution, which means they will have to be strong and stand up in court again legal scrutiny. If the case did go to court the opposing company will challenge your methods, work and results therefor it is vital that the quality is extremely high. With all work carried out the reputation of the company and the Public Analyst are at stake – so it is important for all stages of the work to be completely accurate. The majority of these companies are funded by public money – this means that the public need to see that the company is producing high quality, accurate results for funding to continue – lack of funding could result in political implications. External
…show more content…
Calibrated glassware and balances were used to make sure all measurements were very accurate. We shook the prepared solution to ensure that they were homogeneous. To obtain concordant results we repeated the titrations. The results that we recorded were calibrated to three decimal places to ensure accuracy. We ensured that all washing was transferred to volumetric flasks. When using the potassium manganate we took readings from the top of the meniscus because of the intense colour of the substance. We ensured the part below the tap on the burette was filled before adjusting it to zero. Throughout the titration we swirled the flask continuously to make sure the substances were evenly distributed. Once we started to get close to the endpoint we used a dropwise addition. We took a reading when the first permanent pink colour formed in the solution in the conical flask. We ensured that all glassware was washed with deionised water and that the burette and pipette respectively were rinsed with the solution they were to

You May Also Find These Documents Helpful

  • Powerful Essays

    Calorimetry Lab

    • 1598 Words
    • 7 Pages

    Another means of modification include using an automatic titration device from Titralabs. The main issue with the volume used for the titrations is that the color change is highly subjective and may change by several mL between partners. These small variations can cause further changes in the calculations later on and could potentially change the results obtained. The automated titration devices use light sensors to notice the change in wavelength in the solution at a given temperature and will thus stop pouring the titrant into the solution when the equivalence point is achieved. In addition, an automated heating chamber could be used to maintain a specific temperature of 80 degrees Celsius when performing titrations because the hot plate will not maintain the temperature of the solution at 80 degrees at all times and therefore may cause you to add more or less volume to the titrated solution. Finally, over the course of the experiment, we noticed different accuracies in the scales we used throughout the lab. The differences between different scales for the same sample go differ by up to 0.100g which could certainly impact the amount of solute we believe we have…

    • 1598 Words
    • 7 Pages
    Powerful Essays
  • Good Essays

    Naoh Synthesis Lab Report

    • 414 Words
    • 2 Pages

    The first step was to prepare 400 mL of an 0.1 M solution of NaOH. This was done by diluting from the 6 M solution that was provided. Next, 0.715g of KHP was weighed using the glazed paper and the triple beam balance. The KHP was then transferred to the 250 mL Erlenmeyer flask. Using a graduated cylinder, 50 mL of deionized water was measured and added to the flask.…

    • 414 Words
    • 2 Pages
    Good Essays
  • Powerful Essays

    The equipment used in this experiment are, Conical flask, Acetic anhydride, Salicylic acid, Concentrated sulfuric acid, Water bath, Distilled water , Cold water, Hot water, Filter paper, Ethanol, Hot plate and Dry watch glass.…

    • 1302 Words
    • 6 Pages
    Powerful Essays
  • Good Essays

    Determining the Unknown Concentration of NaHCO3 (aq) Through Titration Introduction Titration is the accurate addition of a titrant- solution in a burette- into a measured volume of a sample (Kessel, 2003). There are many different types of titration, such as acid-base reaction, redox reactions, precipitation reaction and more (Dohrman). In this lab an acid base titration will be explored. In an acid-base titration, the concentration of an acid or base is unknown and is determined by the adding (from a burette) a solution of known concentration (titrant). Titration is used in many different fields such as medicine to determine different concentrations of chemicals in the blood.…

    • 1657 Words
    • 7 Pages
    Good Essays
  • Good Essays

    Iodometric Titration Lab

    • 472 Words
    • 2 Pages

    The titration takes place in a 250-mL Erlenmeyer flask which we labeled as trial 1-3. Some other materials we used was the 25-mL volumetric pipet, preciously add 25.00 mL of diluted bleach (from step 2) to the reaction flask. Using a 100-mL graduated cylinder, add about 15 mL of distilled or deionized water to the reaction flask. Used a 100-mL graduated cylinder, add about 20 mL of 10% potassium iodide solution to the reaction flask. This 10% KI solution should be clear, and not yellow.…

    • 472 Words
    • 2 Pages
    Good Essays
  • Powerful Essays

    7. Allow NaOH to go into the flask 1 mL at a time. When closer to then end point add one drop. When the solution changes color for 20 seconds, the titration is done. Record the finial buret reading.…

    • 1241 Words
    • 5 Pages
    Powerful Essays
  • Satisfactory Essays

    • Gloves and safety goggles should be worn at all times. Method In all titration experiments careful measurements are very essential in order to gain accurate results. 1. Firstly fill the burette…

    • 621 Words
    • 3 Pages
    Satisfactory Essays
  • Powerful Essays

    The color change can occur quickly, so be ready to stop the valve. In the “rough” section of the report sheet, record the initial, final and net volume (Vfinal-Vinitial). Refill the burette with sodium hydroxide until it reaches the 0.00 mL mark, and allow some to run through the burette tip into the titrated solution.…

    • 1107 Words
    • 5 Pages
    Powerful Essays
  • Powerful Essays

    Firstly, it took time for the tap on the burette to be closed, so even though the titration was complete more acid was being added to the conical flask, this resulted in the reading on the burette higher than usual. Also each titration was carried out by a different person, the reaction times of different individuals will vary and so the tap would be closed at a faster/slower rate depending on the individual. Additionally, different individuals may spot the colour change at different times. Once this problem was noticed the remaining titrations were carried out by the same person to have more consistency in the experiment. Furthermore parallax became an issue when measurements were taken from the burette, if the reading were took at different angles then the values appeared to be different.…

    • 2355 Words
    • 10 Pages
    Powerful Essays
  • Powerful Essays

    First, the burette should be rinsed with the standard solution, the pipette with the unknown solution, and the conical flask with distilled water.…

    • 1352 Words
    • 6 Pages
    Powerful Essays
  • Good Essays

    Titration - raul siegers

    • 1630 Words
    • 7 Pages

    Primary standard and its importance can be justified by its accuracy to find the concentration of a solution, in this lab report; we will measure the concentration of NaOH and test our titration method as well as work with molar mass calculations. This will lead us to the “Standardization” a process where a solution’s concentration is determined accurately by titrating against the primary standard. Most importantly this experiment will enable us to test this system, and achieve a standardization of a NaOH solution.…

    • 1630 Words
    • 7 Pages
    Good Essays
  • Good Essays

    As various chemicals were used in the whole process of this lab, certain variables might have influenced the results in terms of the purity of each chemical or purity of the used filtrate.…

    • 860 Words
    • 5 Pages
    Good Essays
  • Good Essays

    | I used the distilled water to wash out any glassware and storage jars before using them to avoid contamination.…

    • 2387 Words
    • 10 Pages
    Good Essays
  • Good Essays

    5. After the reaction occurred, the height difference from the solution within the eudiometer tube and the top of the liquid volume in the beaker was recorded. The final volume was also recorded.…

    • 464 Words
    • 2 Pages
    Good Essays
  • Powerful Essays

    Materials: 14 test tubes, 1 test tube rack, 1 paper towel, 5 ml Benedicts solution, .5 ml Iodine solution, 2 ml Biuret reagent, hot plate, samples 1-5, A, and B. Procedure: Obtain materials, Label the test tubes 1-5 ad A and B…

    • 897 Words
    • 4 Pages
    Powerful Essays