Preview

Fresh Parsley And Spinach Research

Better Essays
Open Document
Open Document
1192 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
Fresh Parsley And Spinach Research
Research Question: What are the percent concentrations of Fe3+ ions by mass in fresh parsley and spinach leaves?
Scientific Concept Colorimeter measures the absorbance of light by the chemical substances at a certain wavelength. By measuring the absorbance, the concentration of a chemical substance can be determined. For the calibration of the colorimeter, different concentrations of a standard solution and a control (distilled water) are prepared in cuvettes. These cuvettes are put into the colorimeter one by one to calibrate it. After the colorimeter is calibrated, solutions of the substances which their concentrations are wanted to be determined, are put into cuvettes and their concentrations can be determined by this process (Dubey 209).
…show more content…
Put the crucible on the pipe-stem triangle.
4. Light the Bunsen burner, turn to blue flame and heat the crucible until the parsley burns completely.
5. Take the crucible from the pipe-stem triangle and leave it to cool down.
6. Transfer the ash of parsley into a test tube by using a stirring rod.
7. Measure 5 mL distilled water by using a graduated cylinder with a dropper and add distilled water into the test tube, stir it with a stirring rod.
8. Put an empty test tube into a test tube holder.
9. Put filter paper into a funnel and put the funnel into the test tube in the test tube holder.
10. Filter the distilled water-ash mixture.
11. Put 5 mL KSCN solution into the test tube that the filtrate is in by using a
…show more content…
Transfer the water-ash-KSCN mixture into a cuvette by using a dropper.
13. Repeat steps 1-12 for spinach leaf.
Using the colorimeter:
1. Connect the colorimeter to your computer.
2. Adjust the absorbance of the colorimeter to 450nm.
3. Approximately 15 minutes after you have prepared your standard solutions, start measuring the absorbance of the standard solutions by starting from the most dilute standard solution to obtain the calibration curve.
4. Measure the absorbance of parsley and spinach samples.
5. Calculate the amount of Fe3+ ions in parsley and spinach samples. Works Cited
Brooks, David W. “Simple Iron in Food Determination.” Web. 6 Dec. 2017.
"Determination of Iron by Thiocyanate Colorimetry." Canterbury.ac.nz. 2017. Web. 6 Dec. 2017.
Dubey, R. C. Advanced Biotechnology: For B Sc and M Sc Students of Biotechnology and Other
Biological Sciences. S Chand, 2014. Print.
“Iron.” University of Maryland Medical Center. 23 June 2015. Web. 27 Dec. 2017.
National Research Council. Diet and Health: Implications for Reducing Chronic Disease Risk.
1989. Print.
Oborn, Eugene T. Iron Content of Selected Water and Land Plants. United States Government
Printing Office, 1960.

You May Also Find These Documents Helpful

  • Satisfactory Essays

    Chemistry 116 lab review

    • 289 Words
    • 2 Pages

    The first step is to calibrate the colorimeter with0.20 M Fe(NO3)3and set the absorbance at 470 nm since it is known to keep an acidic solution throughout the entirety of the experiment. It was important to do this right at the beginning of the lab since the zeroed value of the acid was the calibration number for all of the other solutions. A total of seven solutions with different dilutions were used throughout the lab to conduct the equilibrium constant. The first step was adding 5 mL of 0.200 M Fe(NO3)3to each of the 5 test tubes. Once this was done, 0.00200 M NCS was added to the test tubes, each receiving a different amount; test tube one received 1 mL NCS-and with each test tube the amount of NCS-would increase by 1 mL, test tube 5 received 5 mL of NCS. . The next step was adding HNO3 to each test tube in different volumes; Test tube one received 10 mL of HNO3 and with each test tube the amount of HNO3 decreased by 1 mL, test tube five had no HNO3 added to it. The addition of these solutions formed five test tubes of different dilutions, but of equal volume, 10 mL each. After all of the previous trials had been completed the final step was to take each test tube and pour it into a different cuvette and measure the absorbance for each. Once the initial concentration was calculated of Fe3+, NCS and FeNCS2+ in molarity. The absorbency values were recorded and used to calculate the formation constant, K f The reference table containing volumes used in each solution is provided below…

    • 289 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Dye Analysis Lab Report

    • 978 Words
    • 4 Pages

    2) Based on maximum absorbance of the dye tested, select the appropriate wavelength on spectrometer.…

    • 978 Words
    • 4 Pages
    Satisfactory Essays
  • Powerful Essays

    7. Refill half of the test tube with room temperature distilled water (at least 10C) and add 1/8 teaspoon of salt to the distilled water in the test tube. Mix well…

    • 1713 Words
    • 7 Pages
    Powerful Essays
  • Good Essays

    3. Measure 10mL of distilled water in the beaker. Then, transfer it to the graduated cylinder to make it easier to pour into the test tube.…

    • 565 Words
    • 3 Pages
    Good Essays
  • Good Essays

    1. Measure 50 mL tap water using the graduated cylinder then add it to one of the beakers…

    • 1094 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Five solutions with a known concentration of cobalt chloride hexahydrate will be used. Each solution will be put into a small cuvette which will ultimately be placed inside the colorimeter to find the amount of light that strikes the photocell; calculating the absorbance. When the absorbance to concentration information is graph it should be a direct relationship resulting in a linear relationship.…

    • 569 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Lab Report

    • 2156 Words
    • 9 Pages

    The objective of this lab was to consult for the FDA regarding a recently surfaced scandal involving false reporting of iron content in cereal as well as iron tablets. The makers of the cereal and the iron tablets, respectively, were allegedly reporting higher amounts of iron in their products than actually existed, as a way to save money but continue to provide products with “adequate” amounts of iron. The FDA needed consulting in order to analyze the products and use the data to determine the true amount of iron in each product, as well as confirm that the iron was usable by the human body. The methods used to analyze the products, data, and results will be provided in the sections below.…

    • 2156 Words
    • 9 Pages
    Good Essays
  • Better Essays

    7. Using the crucible tongs, hold a dry piece of Magnesium ribbon in the flame. Quickly place the burning ribbon on the watch glass. Compare the appearance of the ribbon before and after burning.…

    • 575 Words
    • 5 Pages
    Better Essays
  • Better Essays

    Case Study

    • 2180 Words
    • 7 Pages

    Approximately two-third of the iron in the body is stored in hemoglobin. The Surplus iron that is not available directly in the blood is stored in the iron-storing proteins known as ferritin. When dietary iron has been plentiful, ferritin is constantly and rapidly made and broken down, providing an ever-ready supply of iron. Ferritin is used as…

    • 2180 Words
    • 7 Pages
    Better Essays
  • Good Essays

    To construct a calibration curve, three samples with different known concentrations and a blank solution are prepared and their absorbances are measured with a UV-Vis spectrophotometer (Table 1). The absorbances of three unknown samples with same concentration and a blank are measured (Table 2). The blank solutions are used as a reference solution to calibrate the colorimeter. The volumes of Fe solution for the delivery volume errors in the 10 ml graduated pipet are corrected (Table 3). The molarity (μg/mL) of Fe (o-phenanthroline)32+ in each standard solution is calculated by equation 2 (Table 4).…

    • 701 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    6. Allow your set-up to stand for approximately 30 minutes or until you see a distinct color change in the bag or in the beaker. Record the final color of the solution in the bag, and of the solution in the beaker, in data table. Weigh the bag and record the weight.…

    • 750 Words
    • 3 Pages
    Satisfactory Essays
  • Good Essays

    Then we used a magnet wrapped in paper to conduct a magnetism test to determine whether or not iron was contained in the mixture. Then the iron was removed from the mixture using the magnet. After that we put 1/8 of an inch of the mixture into two vials labeled A and B before filling them with distilled water and shaking them in order to change the mixture from solid to liquid. Then we poured the contents of vial A into a test tube and recorded the color. Then we made a filter and put it into another test tube.…

    • 787 Words
    • 4 Pages
    Good Essays
  • Satisfactory Essays

    Iron is a vital constituent of plant and animal life, and is the key component of haemoglobin.…

    • 279 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Organic Molecules

    • 1537 Words
    • 7 Pages

    5. Heat the test tubes in a boiling water bath for 2 minutes. Record any color changes in the data table you created.…

    • 1537 Words
    • 7 Pages
    Good Essays
  • Good Essays

    Iron has been thought of to increase free radical damage in the body and has been linked to an increase risk of cancer and…

    • 453 Words
    • 2 Pages
    Good Essays