The glassware that was used in the experiment was (2) 100mL volumetric flask, and a (1) 250 mL beaker. At the start of the experiment, we prepared standards of benzoic acid solutions that contained 2,4,6,8, and 10 mg/L in 0.10M HCl, our group prepared the 6 and 6 mg/L standards for all the groups within the laboratory. In one of the 100mL volumetric flask it contained 6 mg/L benzoic acid + 10 mL HCl, then diluted to the mark on the flask with DI Water. In the other 100mL volumetric flask it contained 8 mg/L benzoic acid + 10 mL HCl, then diluted to the mark on the flask with DI water. Standards of caffeine were also prepared that contained 4,8,12,16 and 20 mg/L in 0.10M HCl. All other standards were prepared by other lab groups. These standards were used to obtained a series of calibration curves. We then prepared the monster energy drink, by warming 20 mL of the monster energy drink on a hot plate in order to expel CO2 and filtered the warm liquid through filter paper in order to remove any particles, after making sure the monster energy drink was cooled to room temperature; 4.00 mL were pipetted into a 100-mL volumetric flask. 10.0 mL of 0.10M HCl were added to the 100-mL volumetric flask, and diluted to the marking on the flask with DI water. A second sample was prepared by obtaining 2.00 mL of monster
The glassware that was used in the experiment was (2) 100mL volumetric flask, and a (1) 250 mL beaker. At the start of the experiment, we prepared standards of benzoic acid solutions that contained 2,4,6,8, and 10 mg/L in 0.10M HCl, our group prepared the 6 and 6 mg/L standards for all the groups within the laboratory. In one of the 100mL volumetric flask it contained 6 mg/L benzoic acid + 10 mL HCl, then diluted to the mark on the flask with DI Water. In the other 100mL volumetric flask it contained 8 mg/L benzoic acid + 10 mL HCl, then diluted to the mark on the flask with DI water. Standards of caffeine were also prepared that contained 4,8,12,16 and 20 mg/L in 0.10M HCl. All other standards were prepared by other lab groups. These standards were used to obtained a series of calibration curves. We then prepared the monster energy drink, by warming 20 mL of the monster energy drink on a hot plate in order to expel CO2 and filtered the warm liquid through filter paper in order to remove any particles, after making sure the monster energy drink was cooled to room temperature; 4.00 mL were pipetted into a 100-mL volumetric flask. 10.0 mL of 0.10M HCl were added to the 100-mL volumetric flask, and diluted to the marking on the flask with DI water. A second sample was prepared by obtaining 2.00 mL of monster